• Title/Summary/Keyword: Water Vapor

Search Result 1,651, Processing Time 0.022 seconds

Permeation Characteristics of Air and Water Vapor through ABS/filler Hybrid Films (ABS 복합 필름의 공기 및 수증기 투과 특성)

  • Hong, Seong-Uk;Ko, Young-Deok
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.256-259
    • /
    • 2008
  • In this study, graphite or zeolite 4A was mixed with poly(acrylonitrile-butadiene-strene) (ABS) to make hybrid films, and permeation characteristics of air and water vapor through these films were investigated. In all cases, gas permeabilities of hybrid films were lower than that of pure ABS films. The permeability decrease of oxygen was slightly larger than that of nitrogen, resulting in the little decrease of $O_2/N_2$ selectivity. In addition, the water vapor transfer rates (WVTR) of hybrid films were about half of ABS film's. The decrease of permeabilities may be owing to the increase of tortuosity for diffusion in hybrid films.

Performance of a Plate-Type Enthalpy Exchanger Made of Papers Having Different Properties (종이 물성에 따른 판형 전열교환기의 성능)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Song, Gil-Sup;Kim, Dong-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.547-555
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Papers having different properties were made from the same pulp by calendering or refining. Enthalpy exchanger samples were made from the papers, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were obtained, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that effective efficiency of latent heat transfer was approximately the same independent of the samples, which suggests that papers made of the same pulp show similar water vapor transmission characteristics independent of the degree of calendering or refining. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

Effect of Paper Properties on the Performance of a Enthalpy Exchanger (종이 물성이 전열교환 엘리먼트 성능에 미치는 영향)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Song, Gil-Sup;Kim, Dong-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

The Effect of Water Vapor on th ePermeation of Oxygen/Nitrogen through Polysulfone Hollow -Fiber Membrane (폴리설폰 중공사막에 대한 산소/질소의 투과도에 미치는 수분의 영향)

  • 김진천;김종수;조정식;최기석;이광래
    • Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • The effects of water vapor on the permeation rates of oxygen and nitrogen through poly sulfone hollow-fiber membrane were investigated. The permeation rates of both 02 and $O_2$ were decreased significantly owing to the presence of water vapor. The permeation rate of oxygen with 100% relative humidity was reduced by as much as 20%, while the permeation rate of nitrogen decreased by 14% at 30 "C and 3kgf/$cm^2$ of upstream pressure. The permeation rates of $O_2$ were declined monotonously with running time and arrived at steady state values by the presence of water vapor. However, those of $N_2$ increased tentatively and then decreased to the steady state.tate.

  • PDF

Prediction of Diesel Fuel Spray Characteristics in Compression Ignition Engine Cylinder by Intake Humidification (흡기 가습에 의한 압축 착화엔진 실린더 내 디젤 연료 분무 특성 예측)

  • Min, Se Hun;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.23 no.1
    • /
    • pp.30-35
    • /
    • 2018
  • The objective of this study is to predict numerically the effect of intake humidification on the injected diesel fuel spray characteristics in a compression ignition engine. In this work, Wave model and Ducowicz model were applied as the break-up model and evaporation model, respectively. The amount of water vapor for the humidification was changed from 0% to 30% of injected fuel mass. The number of applied meshes was generated from 49,000 to 110,000. At the same time, the results of this work were compared in terms of spray tip penetration, SMD and equivalence ratio distributions. It was found that the cylinder temperature and cylinder pressure were decreased with increasing water vapor mass by vaporization latent heat and specific heat, however, the difference was very small. So, the spray tip penetration was not different by water vapor mass. Also, higher equivalence ratio distributions were observed with increasing water vapor mass by the improvement of fuel atomization.

Study on the Water-Vapor Permeation through the Al Layer on Polymer Substrate (폴리머 기판에 형성한 알루미늄 보호막의 수분침투 특성 연구)

  • Choi, Young-Jun;Ha, Sang-Hoon;Park, Ki-Jung;Choe, Youngsun;Cho, Young-Rae
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.873-880
    • /
    • 2009
  • Water-vapor permeation through metallic barriers deposited on polymer substrates has been an important technological issue because the performance of the barrier is critical to the reliability of flexible organic devices. For the development of long-lifetime flexible organic devices, two different sets of samples were designed and demonstrated from the viewpoint of the water-vapor transmission rate (WVTR). Aluminum (Al) and polyethylene terephthalate (PET) were chosen for the barrier layer and the polymer substrate, respectively. Two stacking structures, a single-layer (Al/PET) structure and a double-layer (Al/PET/Al) structure, were used for the WVTR measurement. For the single-layer structure, the WVTR decreases as the thickness of the barrier layer increases. Compared to the single-layer sample, the double-layer sample showed superior WVTR performance (by nearly three times) when the total thickness of the Al barrier was greater than 100 nm.

Corrosion Behavior of Ytterbium Silicates in Water Vapor Atmosphere at High Temperature for Environmental Barrier Coating Applications (환경차폐코팅용 이터븀 실리케이트의 고온 수증기부식 거동)

  • Min-Ji Kim;Jae-Hyeong Choi;Seongwon Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.443-450
    • /
    • 2023
  • SiC/SiCf CMC is vulnerable to water vapor corrosion at a high temperature of 1500℃. So, EBC (Environmental Barrier Coating) materials are required to protect Si-based CMCs. Ytterbium silicates are reported to have coefficient of thermal expansion (CTE) similar to that of the base material, such as SiC/SiCf CMC. When the EBC are materials exposed to high temperature environment, the interface between ytterbium silicates and SiC/SiCf CMC is not separated, and the coating purpose can be safely achieved. For the perspective of EBC applications, thermally grown oxide (TGO) layer with different CTE is formed by the reaction with water vapor in EBC, which leads to a decrease in life time. In this study, we prepare two types of ytterbium silicates to observe the corrosion behavior during the expose to high temperature and water vapor. In order to observe this behavior, the steam-jet furnace is prepared. In addition, phase formation of these ytterbium silicates is analyzed with microstructures by the before/after steam-jet evaluation at 1500℃ for 100 h.

Effect of Fiber Content, Yarn Size and Construction of Knit Fabrics on the Buffering Capacity against Water Vapor (편성물의 섬유의 종류, 실의 굵기 및 니트타입에 따른 투습완충능력)

  • Yoo, Hwa-Sook;Hu, Yoon-Sook;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.20 no.1
    • /
    • pp.228-238
    • /
    • 1996
  • The purpose of this study was to evaluate the effect of chacteristics of knit fabrics on the microclimate of the skin simulating system. To determine the effect of characteristics of knit fabrics, vapor state of sweat pulse was simulated in the closed system. Different contents of fibers such as cotton, wool and polyester with different yarn size and knit types were chosen for specimens. The changes of humidity and temperature of air layer in the simulated systems were measured. Buffering indices, $K_d$ and $\beta_r$, were determined by considering $\alpha_p, \DeltaP_{max}, t_{max}, and tan\beta$. Physical properties of knit fabrics such as thickness, porosity, air resistance and moisture vapor transport were measured. Results showed that vapor pressure of wool was lower than cotton or polyester This was attributed to the hydrophilicity of wool which absorbed moisture rather quickly and retained in the knit fabric. The time to decrease vapor pressure was faster for polyester than cotton or wool. As a result, $K_d$ was in the order of wool> polye, item> cotton. $\beta_r$ of wool was rower than cotton or polyester due to its lowers porosity and slower desorption rate. For the yarn size, $K_d$ was in the order of 80's> 60's> 30's; thinner and lighter yarn showed better water vapor transport property. For knit type, buffering capacity of single jersey was better than interlock knit fabric. Statistical analysis showed that the air permeability was the most influential factor far the water vapor transport properties.

  • PDF

Moisture and Heat Transfer Characteristics of Waterproof and Water Vapor Permeable Coated Fabrics (기능성 투습방수 코팅포의 수분 및 열전달 특성)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.151-163
    • /
    • 1999
  • The purpose of this study was to investigate the thermal resistance and the liquid/vapor water transfer characteristics of four waterproof and water vapor permeable coated fabrics with the ground fabric called nylon taffeta. In order to establish the experimental environment, outdoor temperature and humidity in Taegu during the last three years were examined and the experiment was performed at (1) $15^{\circ}C$, 50% R.H., (2) $20^{\circ}C$, 60% R.H., (3) $25^{\circ}C$, 65% R.H., which were the average standards in spring and fall. The test results were as follows ; 1. Among physical parameters, the thinner the thickness was, the higher the water vapor permeability was. But the porosity in thickness was not proportional to water vapor permeability linearly. 2. The thicker the thickness of specimens was and the smaller the bulk density and porosity were, the higher the thermal resistance. And the results also shown that the larger the temperature difference between the environmental temperature and the hot plate was, the more the difference of CLO values was apparent. 3. Since the contact angle of all specimens are above $90^{\circ}$, the all specimens have a good performance in waterproof. The more the specimens surface were rough, the higher the thermal resistance was. 4. According to the result of performing moisture transfer test using the simulating body skin-clothing-environment system, the humidity sensor placed in between the fabric and the environment detected the full saturation in 10 minutes after the experiment had began at $15^{\circ}C$, 50% R.H. and in 15 minutes after the experiment both at $20^{\circ}C$, 60% R.H. and at $25^{\circ}C$, 65% R.H. 5. ${\Delta}$ values of the humidity sensors placed in between the human body and the fabric and in between the fabric and the environment fluctuated repeatedly within the range of $20{\sim}40%$ at $20^{\circ}C$, 60% R.H., and $15{\sim}30%$ at $25^{\circ}C$, 65% R.H.

  • PDF

A Study on the Change of Humidity by City Size in South Korea (한국의 도시 규모별 습도 변화에 관한 연구)

  • Ko, Myungchan;Lee, Seungho
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.1
    • /
    • pp.19-36
    • /
    • 2013
  • This study aimed to investigate the change of humidity by city size in South Korea. Using daily mean relative humidity and water vapor pressure during the period of 1954~2011 for 14 weather stations in South Korea, the change of humidity by city size was analyzed. The change of relative humidity had a continuous decreasing trend for the period of 1954~2011. The decreasing trend in large city was bigger than these of rural one. The seasonal relative humidity was significantly changed in spring and winter. The change of water vapor pressure was rarely changed significance of the results by city size. It was not shown the result to constant trend by city size. There was a negative correlation between relative humidity and mean temperature. And change of relative humidity was correlated with city size. Moreover, there was not correlation between relative humidity and water vapor pressure by city size. The decreasing trend of relative humidity was similar to increasing trend of temperature by urbanization. However, there was not shown significant result of water vapor pressure.

  • PDF