• Title/Summary/Keyword: Water Usage

Search Result 745, Processing Time 0.03 seconds

Evaluation of Field Applicability for All-In-One Smart Water Meter to Measure both Water Quantity and Quality in Office Building Water Usage (사무실 사용용수의 수량/수질 동시 측정이 가능한 일체형 스마트 워터 미터의 현장 적용성 평가)

  • Lee, Saeromi;Oh, Hyun Je;Joo, Jin Chul;Ahn, Chang Hyuk;Park, Jae Roh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.653-662
    • /
    • 2016
  • Recently, advanced metering infrastructure (AMI) has been recognized as a core technology of smart water grid, and the relevant market is growing constantly. In this study, we developed all-in-one smart water meter of the AMI system, which was installed on the test-bed to verify both effectiveness and field applicability in office building water usage. Developed 15 mm-diameter smart water meter is a magneto-resistive digital meter, and measures flow rate and water quality parameters (temperature, conductivity) simultaneously. As a result of the water usage analysis by installing six smart water meters on various purposes in office building water usage, the water usage in shower room showed the highest values as the 1,870 L/day and 26.6 liter per capita day (LPCD). But, the water usage in laboratory was irregular, depending on the many variables. From the analysis of the water usage based on day of the week, the water usage on Monday showed the highest value, and tended to decrease toward the weekend. According to the PCA results and multivariate statistical approaches, the shower room (Group 3) and 2 floor man's restroom sink (Group 1-3) have been classified as a separate group, and the others did not show a significant difference in both water use and water quality aspects. From the analysis of water usage measured in this study, the leak or water quality accident did not occur. Consequently, all-in-one smart water meter developed in this study can measure flow rate and water quality parameters (temperature, conductivity) simultaneously with effective field applicability in office building water usage.

Investigation and Analysis of Unit Industrial Water Usage Considering Latest Industrial Trend (최신 산업동향을 고려한 공업단지 사용량 원단위 분석 연구)

  • Kim, Kibum;Yu, Youngjun;Choi, Woojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.447-457
    • /
    • 2017
  • This study derived the unit of industrial water usage reflecting the latest industry trends. Available for establishing plans such as the master plan for water supply system and analyzed changes in the basic unit by a comparison with the current basic unit values. This study analyzed 4,038 samples with a sampling error of less than 1.5 % at the 95 % confidence level after removing outliers according to a log-normal distribution. As a result, the unit of industrial water usage per site area in the whole manufacturing industry was 7.11 m3/1,000m2/d. The ten industrial categories (C10, C13, C20, C21, C22, C25, C27, C30, C32, C33) showed a similar unit value compared to before, and the four industrials categories (C11, C17, C22, C31) showed a more unit value than before. With regard to the nine industrial categories (C14, C15, C16, C18, C19, C24, C26, C28, C29), the unit value decreased. Cases that companies examined before were the same as the companies examined in this study were analyzed. The result that the changes in the unit industrial water usage were reasonable was obtained. However, in some industrial categories (C17, C14, C24, C29), the unit value was changed by a small number of companies with large-scale water use or unit value of sampling had a large deviation. It was considered necessary to survey them periodically. The unit of industrial water usage derived by the survey in this study reflects the current industrial trends in 2016. Water use in manufacturing companies has continuously changed by the development of manufacturing technologies and simplification of manufacturing processes. In order to deal with this, it is considered necessary to survey the usage of industrial water periodically from a long-term perspective.

Analysis of domestic water usage patterns in Chungcheong using historical data of domestic water usage and climate variables (생활용수 실적자료와 기후 변수를 활용한 충청권역 생활용수 이용량 패턴 분석)

  • Kim, Min Ji;Park, Sung Min;Lee, Kyungju;So, Byung-Jin;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.57 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Persistent droughts due to climate change will intensify water shortage problems in Korea. According to the 1st National Water Management Plan, the shortage of domestic and industrial waters is projected to be 0.07 billion m3/year under a 50-year drought event. A long-term prediction of water demand is essential for effectively responding to water shortage problems. Unlike industrial water, which has a relatively constant monthly usage, domestic water is analyzed on monthly basis due to apparent monthly usage patterns. We analyzed monthly water usage patterns using water usage data from 2017 to 2021 in Chungcheong, South Korea. The monthly water usage rate was calculated by dividing monthly water usage by annual water usage. We also calculated the water distribution rate considering correlations between water usage rate and climate variables. The division method that divided the monthly water usage rate by monthly average temperature resulted in the smallest absolute error. Using the division method with average temperature, we calculated the water distribution rates for the Chungcheong region. Then we predicted future water usage rates in the Chungcheong region by multiplying the average temperature of the SSP5-8.5 scenario and the water distribution rate. As a result, the average of the maximum water usage rate increased from 1.16 to 1.29 and the average of the minimum water usage rate decreased from 0.86 to 0.84, and the first quartile decreased from 0.95 to 0.93 and the third quartile increased from 1.04 to 1.06. Therefore, it is expected that the variability in monthly water usage rates will increase in the future.

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

Development of Agricultural Groundwater Usage Model Considering Multipurpose Water in Jeju Island (다목적 용수를 고려한 제주도 농업용 지하수 이용량 모델 개발)

  • An, Jung-Gi;Song, Sung-Ho;Lee, Dong-Rim
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.515-524
    • /
    • 2015
  • The estimation of groundwater usage in Jeju island is important to understand hydrologic cycle system and to plan management of water resource because large amounts of groundwater have been used for agricultural and domestic purpose. The model has been developed to estimate agricultural groundwater usage for garlic at uplands and citrus at orchards raising outdoors using the soil water balance model from FAO 56, respectively. The total amount of water supplied for the crop evapotranspiration and the multipurpose function such as sprout promotion can be simulated by the model. However, due to the discrepancy of water use in initial stage between calculated and observed, the model was calibrated and verified using actual groundwater usage monitoring data for 3.5 years (2011.6 to 2014.12) at three uplands for garlic and three orchards for citrus. Consequently, it would be concluded that the model simulated efficiently actual water usage in that root mean square (RMS) and normalized RMS of the validation stage were less than 8.99 mm and 2.43%, respectively, in two different conditions.

The Characteristics of Water Usage in Jeju Golf Courses (제주지역 골프장의 용수 이용특성)

  • Park, Won-Bea;Kim, Bong-Seok;Yang, Sung-Kee;Moon, Duk-Chul
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1297-1308
    • /
    • 2011
  • This study is to analyze the characteristics of golf course water usage using groundwater and rainwater data obtained from 17 golf courses in Jeju Island during 2007~2009. The groundwater usages were 246,275 $m^3/year$, 213,062 $m^3/year$, 155,235 $m^3/year$, and 126,666 $m^3/year$ in the west, south, east, and north regions, respectively. Monthly rate of the amount of groundwater usage to the amount of permission was 29.5%. The rainfall usages were 386,591 $m^3/year$, 326,464 $m^3/year$, 251,248 $m^3/year$, and 232,061 $m^3/year$ in the south, west, east, and north regions, respectively. Monthly rate of rainwater usage to the amount of water retention of golf courses was 19.6%. The average annual water usage in the 17 golf courses was 499,377 $m^3/year$. From the average usage, it was found that the rainwater usage (305,126 $m^3/year$ ) was 1.6 times higher than that of groundwater (194,251 $m^3/year$ ). That means the annual average rainwater usage to the entire water usage was 61.1%, which was above the criteria of 40%.

Comparative analysis of linear model and deep learning algorithm for water usage prediction (물 사용량 예측을 위한 선형 모형과 딥러닝 알고리즘의 비교 분석)

  • Kim, Jongsung;Kim, DongHyun;Wang, Wonjoon;Lee, Haneul;Lee, Myungjin;Kim, Hung Soo
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1083-1093
    • /
    • 2021
  • It is an essential to predict water usage for establishing an optimal supply operation plan and reducing power consumption. However, the water usage by consumer has a non-linear characteristics due to various factors such as user type, usage pattern, and weather condition. Therefore, in order to predict the water consumption, we proposed the methodology linking various techniques that can consider non-linear characteristics of water use and we called it as KWD framework. Say, K-means (K) cluster analysis was performed to classify similar patterns according to usage of each individual consumer; then Wavelet (W) transform was applied to derive main periodic pattern of the usage by removing noise components; also, Deep (D) learning algorithm was used for trying to do learning of non-linear characteristics of water usage. The performance of a proposed framework or model was analyzed by comparing with the ARMA model, which is a linear time series model. As a result, the proposed model showed the correlation of 92% and ARMA model showed about 39%. Therefore, we had known that the performance of the proposed model was better than a linear time series model and KWD framework could be used for other nonlinear time series which has similar pattern with water usage. Therefore, if the KWD framework is used, it will be possible to accurately predict water usage and establish an optimal supply plan every the various event.

Development of replacement priority by analysis of effect of water meter replacement (수도미터 교체 우선순위 선정기준 개발)

  • Son, Dong-Wan;Kim, Dong-Hong;Lee, Doo-Jin;Jung, Kwan-Sue
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.509-516
    • /
    • 2014
  • This study describes a reasonable planning method for water meter replacement which can minimize the metering under-registration for an increasement of revenue water. The increment analysis of real water usage was used to establish a replacement plan. The meter replacement database collected from K City was used as the basis of this analysis. The database included 964 connections of domestic and non-domestic consumers that had their meter replaced by aging at 2011. The result showed that the corelation between unregistered water volume and water meter age was lower than commonly expected where the current criteria of replacement is only water meter age(8 years) excluding the meters older than 13 years. And in the analysis result of water usage for 8 years, the total amount and increment of water usage had a significant effect on unregistered water volume. However the relation was different tendency as a total volume and slope of increment. In case of total water volume was larger than 10,000, larger than 7,000 and increment of 0.0 ~ -0.3, larger than 6,000 and increment more than -0.3 were analysed to need a replacement because of metering under-registration.

A Research on Understanding about Water Usage, Recognition and Application among Primary and Secondary School Teachers in Daegu (물사용 인식 및 실천에 관한 조사 연구-대구광역시 초${\cdot}$중등교사를 대상으로-)

  • Kwak, Hong-Tak;Jeon, Eun-Jeong;Lee, Ok-Hee
    • Hwankyungkyoyuk
    • /
    • v.17 no.2
    • /
    • pp.60-78
    • /
    • 2004
  • A survey performed on property of water usage, a recognition and stand on water, and awareness of practice related to water saving among primary and secondary teachers in Daegu metropolitan city leads to the following result. First, regarding the actual condition of water usage, boiled tap water was most preferred, followed by purified tap water, mineral water, and water from a mineral spring respectively. Second, the result of a survey regarding a recognition and stand on water presents that the quality of purified water and mineral water is generally trusted, not including tap water. A majority of teachers barely had any ideas on the process of tap water supplies and sewage disposal system. Third, another survey was performed to determine whether there's a gender difference on a general recognition of and stand on water usage, actual practice of water saving and love for water. As a result, 7 out of 25 questions showed the difference of significance by p<.05. As for tap water service and sewage disposal system, there were differences on 5 out of 6 questions, indicating that male teachers are more knowledgable than their female counterparts. Fourth, the result of the research about the recognition and attitudes about water and water saving of the teachers who were categorized by the age group showed that 14 questions of the 25 questions had differences in p<.05 level. Teachers in their twenties and thirties had less interest than those in their forties and fifties.

  • PDF

A Study on Economic benefits for Water Control Device Installed with a Flush Valve on a Toilet (세척밸브 급수제어장치 설치에 따른 경제적 효과 분석)

  • Park, Kang-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.656-661
    • /
    • 2011
  • The amount of water resources that can be used tend to be decreased gradually. In contrast, the rapidly increasing water consumption is a problem that need to be addressed. Renovation and equipment replacement to improve energy efficiency and to reduce expenditure for building usage is required. But the excessive initial investment cost and the prolonged of pay back period may be uneconomical choice. Water usage for cleaning the toilet bowl accounts for 27%of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed for the economic effects. Water-saving valve was used 5.6 ${\ell}$/time for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}$/time. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.