• Title/Summary/Keyword: Water Tank Test

Search Result 388, Processing Time 0.024 seconds

The Experimental Research for the Use Characteristics of the Passive and Active type Domestic Solar Hot Water Systems (자연형 및 설비형 태양열 온수기의 이용특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kwak, Hee-You
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.82-88
    • /
    • 2013
  • There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

Design, manufacture and field test of a surface water storage tank providing irrigation water to upland crops

  • Shin, Hyung Jin;Kim, Young-Joon;Lee, Jae Young;Kim, Hwang-Hee;Jo, Sung Mun;Cha, Sang Sun;Hwang, Seon-Ah;Lee, Seung-Kee;Park, Chan Gi
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.4
    • /
    • pp.1057-1069
    • /
    • 2020
  • For most upland crops in Korea, underground water is used to ensure an adequate water supply. Thus, surface water storage tanks are needed to supply surface water from reservoirs or streams. This study discusses the design, manufacture and monitoring of a water storage tank capable of reliably supplying water to crops and preventing the inflow of floating debris. The study was conducted in an apple orchard in Yesan-gun, Chungcheongnam-do in Korea. Based on the water requirements of the crops and size of the orchard, a required flow volume of about 0.6 ㎥·h-1 was determined, along with a surface water storage tank capacity of 1.2 ㎥. Following a comparison with other materials, stainless steel (STS) was used to construct the water tank. The tank was designed to provide 14 hours of irrigation, enabling a small-capacity, cost-efficient tank design to be used. A surface water irrigation test was performed using the surface water storage tank. The average surface water irrigation flow rate was 0.00045 ㎥·m-2·h-1. The water quality test showed that the pH, suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) values satisfied the reference values for agricultural water. The test results showed that the surface water storage tank evaluated in this study allows for crop irrigation when there is a lack of groundwater during droughts.

Thermal Stratification Effects Near an Interface by Horizontal Inflow of Cold Water in Thermal Storage Tank (냉수가 수평유입되는 열저장탱크의 중간 경계면 부근에서의 열성층 효과)

  • Hwang, Sung-Il;Pak, Ee-Tong
    • Solar Energy
    • /
    • v.8 no.2
    • /
    • pp.46-56
    • /
    • 1988
  • This investigation concerns thermal stratification of the water due to the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the water in the test tank (1m wide, 1m high, 2.1m long) and the temperature of the inflow water into the tank; flow rate of circulating water and height of the sink diffuser in the test tank. The additional objectives was to observe a stratification phenomena near an interface by measuring the velosities and the temperature difference and investigate an availabilities of the better effective hot water through establishing thermocline near an interface around the bottom of the tank. Following results were obtained through the experiments. 1. When the flow rate was constant and the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the flow in the test tank and the temperature of the inflow water increased by 5.6, 9.5, 13.5($^{\circ}C$), obtained the better effective advantage of hot water and the stress near an interface increased gradually. 2. When the ${\Delta}T=T_{\infty}-T_i$ was constant and flow rate increased by 4.0, 4.8, 6.4, 8.0 (LPM), obtained the better effective advent age of hot water and the mean stress near an interface increased gradually. 3. When the height of the sink diffuser was 25cm from tank bottom in comparison with 50cm, obtained the better effective advantage of hot water and the mean stress near an interface increased.

  • PDF

Seismic Performance Evaluation of Externally Reinforced Panel Water Tank Using Shaking Table Tests (진동대 실험을 통한 외부보강형 판넬조립식 물탱크의 내진성능평가)

  • Park, Se-Jun;Won, Seong-Hwan;Choi, Moon-Seock;Kim, Sang-Hyo;Cheung, Jin-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.151-157
    • /
    • 2013
  • In this study, an externally reinforced structural system for SMC(Sheet Molding Compound) panel water tank, designed according to the Japanese design code, is experimented to evaluate its seismic performance. The test tank is 3m long, 2m wide and 3m high, considering the capacity and size of the shaking table. The measured hydrodynamic pressures are found to be approximately 70% of the Japanese design code values. It may be partially due to the convex shape effect of the unit panels. The analytical results of externally reinforced system based on the measured dynamic water pressures are found in good agreement with the test results. If the design hydrodynamic pressures are estimated properly, the proposed analytical model for the externally reinforced water tank becomes a useful design tool and the Japanese design code is found to provide a safe design for the external frames of SMC panel water tank.

Utilizing the grazing effect of fresh water clams (Unio douglasiae) for the remediation of algal bloom during summer

  • Nam, Ki-Woong;Lee, Jeong-Ryul;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.31 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The occurrence of 'algal bloom', caused by the mass proliferation of phytoplankton, causes serious problems in streams and lakes in Korea. Therefore, in this study, the phytoplankton filter-feeding trait of Unio douglasiae, a type of freshwater clam, was used to reduce the algal bloom in outdoor water tanks during the summer. This involved the construction of a U. douglasiae cultivation apparatus, wherein 1,000 clams were divided into 8 rectangular baskets arranged in the shape of an empty square. The control tank was manufactured in exactly the same shape within the water tank, but without the addition of clams. The algal bloom-reducing effect of U. douglasiae was confirmed by the measurement of (and comparing between) the water quality at the center and periphery of the test and control cultivation apparatus. Water quality measurements included the measurement of water temperature, pH, turbidity, dissolved oxygen (DO) content, and chlorophyll-${\alpha}$ concentrations; the water quality was measured twice a month between June and November 2014.The results of these analyses did not show a significant difference in water quality (temperature, pH, turbidity, DO) between the center and periphery of the test and control tanks. However, the chlorophyll-${\alpha}$ concentration was observed to be much lower at the center of the test tank compared to that at the center and periphery of the control tank, as well as at the periphery of the test tank. This was believed to be a result of the U. douglasiae surrounding the center of the test tank, which prevented the influx of plankton from the periphery. Accordingly, the results of these analyses suggest the possibility that U. douglasiae cultivation could reduce the proliferation of algal blooms in lakes and streams during the summer. In particular, these results indicate possible improvements in U. douglasiae activity (reduction in algal blooms) by their effective arrangement in the water bodies.

A Study on the Surge Tank (수압조절수조(Surge Tank)에 관한 연구)

  • 남선우
    • Water for future
    • /
    • v.6 no.1
    • /
    • pp.29-35
    • /
    • 1973
  • For the simplicity in the analytical solution, the simple surge tank has been chosen for the test where an unsteady flow is porduced by suddenly closing the valve controlling the discharge. The valve is loated immediately downstream from the surge tank. Momentumn equations in the penstock and in the surge column are measured recored on the oscillograph and then the calibration of surge column heights and scale readings on the oscillograph trace are made. The diameter of the penstock are determined by the trial and error method. The water levels in the surge column are computed by numerical integration of the differential equation of the surge tank. The relationships between the results from the experiment and numerical computation are figured, compared and discussed.

  • PDF

Analysis of Internal Overpressure by Pipe Cross-Sectional Area Ratio and Filling Rate in the Hydraulic Test of Shipboard Tank (수압시험 시 관 단면적 비 및 충수 속도별 탱크 내부 과압 발생에 관한 해석)

  • Geun-Gon Kim;Tak-Kee Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.6
    • /
    • pp.460-472
    • /
    • 2023
  • This study was conducted based on the case of an accident (excessive deformation) that occurred during the hydraulic test of a shipboard tank manufactured in accordance with the design regulations. Over-pressure phenomenon was noted as the main cause of accidents in the process of testing tanks without physical damage, which can be found in external factors such as cross-sectional difference between inlet pipe and air pipe and higher water filling rate than the recommended one. The main goal of this paper is to establish a safe water filling rate according to the range of sectional area ratio(SAR) reduced below the regulations for each test situation. The simulation was conducted in accordance with the hydraulic test procedure specified in the Ship Safety Act, and the main situation was divided into two types: filling the tank with water and increasing the water head to the test pressure. The structural safety evaluation of the pressure generated inside the tank and the effect on the structure during the test was reviewed according to the SAR range. Based on the results, guidelines for the optimal filling rate applicable according to SAR during the hydraulic test were presented for the shipboard tanks used in this study.

Correlative Experimental Study Between The Results of Circulating Water Channel and Towing Tank Tests (회류수조와 예인수조 시험결과의 상호관계의 실험적 연구)

  • Lee, K.J.;Ra, Y.K.
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.4
    • /
    • pp.37-45
    • /
    • 2003
  • Model tests using 2.0m model of the series 60 form( $C_{b}$= 0.6) were carried out in the Circulating Water Channel (CWC) in the Chosun University (CU, Korea) for the purpose of a correlative study with Towing Tank (TT). Resistance, propeller open water, self propulsion and wake survey tests were carried out and the results were extrapolated to the ship scale. These results were compared with the extrapolated ship values based on the model test of 7.0m model in the TT at the Korea Research Institute of Ships and Ocean Engineering (KRISO, Korea). The CWC test results were correlated with the results of the towing tank tests.s.

Correlative Experimental Study Between The Results of Circulating Water Channel and Towing Tank Tests

  • Lee, Kwi-Joo;Kim, Kyoung-Hwa;Isaacs, Karl Antony
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.70-75
    • /
    • 2003
  • Model tests using 2.0m model of the series 60 form ($C_{b}$ = 0.6) were carried out in the Circulating Water Channel(CWC) in the Chosun University(CU, Korea) for the purpose of a correlative study with Towing Tank(TT). Resistance, propeller open water, self propulsion, and wake survey tests were carried out and the results were extrapolated to the ship scale. These results were compared with the extrapolated ship values based on the model test of 7.0m model in the TT at the Korea Research Institute of Ships and Ocean Engineering (KRISO, Korea). The CWC test results were correlated with the results of the towing tank tests.

  • PDF

A Comparative Performance Test for Turbine in Wind Tunnel and Towing Tank (풍동과 예인 수조를 이용한 터빈 성능 비교 시험)

  • Kang, Jung-Min;Lee, Yeong-Ho;Lee, Kyu-Chan
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.42-49
    • /
    • 2011
  • The objective of this paper is to suggest a new method of a wind turbine performance test. The performance test of a wind turbine is generally carried out in a wind tunnel. The test needs not only a high-accuracy measuring system but also durable structure to withstand high speed turbine rotation and wind flow. Therefore, we tried turbine performance test using a towing tank to improve stability and reliability. Because a turbine rotates more slowly and generates more torque in the water than in the wind tunnel under similarity conditions. In this study, we developed turbine performance test systems and verified the turbine test method using a towing tank through comparing results of the wind tunnel and the towing tank test.