• Title/Summary/Keyword: Water Supply Facilities

Search Result 414, Processing Time 0.033 seconds

The Effect of Road Networks on Urban Resilience in Flooding (도시침수 시 도로네트워크가 도시회복도에 미치는 영향 분석)

  • Hyung Jun Park;Dong Hyun Kim;Hyun Jung Lee;Seung Oh Lee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.2
    • /
    • pp.85-98
    • /
    • 2023
  • Flood is one of the most frequent natural disasters worldwide. In Korea, the probability of urban flooding is greatly increasing due to complex factors such as global warming, an increase in impervious areas, and limitations in expanding water supply facilities in existing urban areas. However, large-scale civil engineering works to prevent urban inundation are socially and economically difficult to obtain national consent. Recently the importance of resilience, which is the ability to return to the original state after a disaster through rapid recovery while preparing for natural disasters to a level that the local community can afford socially and economically, is increasing. Accordingly, various studies on urban resilience have been conducted, but the resilience measurement method related to the lifeline that provides essential services of the city is insufficient. However, among lifelines, road networks are important facilities for the transportation of recovery resources and rapid recovery in the event of a natural disaster, so road networks are a major factor that must be considered when measuring the degree of recovery of a city in the field of natural disasters. Therefore, this study proposes a recovery evaluation method considering the characteristics of resilience and road networks in the urban flooding field and analyzes the effect of road networks on urban resilience.

Development of Strategies to Improve Water Quality of the Yeongsan River in Connection with Adaptation to Climate Change (기후변화의 적응과 연계한 영산강 수질개선대책 개발)

  • Yong Woon Lee;Won Mo Yang;Gwang Duck Song;Yong Uk Ryu;Hak Young Lee
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.3
    • /
    • pp.187-195
    • /
    • 2023
  • Almost all of the water from agricultural dams located to the upper of the Yeongsan river is supplied as irrigation water for farmland and thus is not discharged to the main stream of the river. Also, most of the irrigation water does not return to the river after use, adding to the lack of flow in the main stream. As a result, the water quality and aquatic health of the river have become the poorest among the four major rivers in Korea. Therefore, in this study, several strategies for water quality improvement of the river were developed considering pollution reduction and flow rate increase, and their effect analysis was performed using a water quality model. The results of this study showed that the target water quality of the Yeongsan river could be achieved if flow increase strategies (FISs) are intensively pursued in parallel with pollution reduction. The reason is because the water quality of the river has been steadily improved through pollution reduction but this method is now nearing the limit. In addition, rainfall-related FISs such as dam construction and water distribution adjustment may be less effective or lost if a megadrought continues due to climate change and then rainfall does not occur for a long time. Therefore, in the future, if the application conditions for the FISs are similar, the seawater desalination facility, which is independent of rainfall, should be considered as the priority installation target among the FISs. The reason is that seawater desalination facilities can replace the water supply function of dams, which are difficult to newly build in Korea, and can be useful as a climate change adaptation facility by preventing water-related disasters in the event of a long-term megadrought.

An Analysis of Scour Effect on Hydraulic Energy Dissipater Installation at Weir Downstream (보 하류부 감세공 설치에 대한 세굴 변화 분석)

  • Kang, Joon-Gu;Lee, Chang-Hun;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.453-458
    • /
    • 2016
  • While the design of weirs requires a scour-considered strategy, research on the analysis of the effectiveness of hydraulic energy dissipaters and design criteria are scarce due to the limited experimental facilities and restraint in the experiment conduction period. The study analyzed the scour dissipation effect of multidirectional dissipaters to improve the scour problems of a weir downstream and suggests design criteria to minimize scour. A hydraulic model experiment was conducted for Nakdong River Hapcheon-Changnyeong Weir and a model in 1/25 of horizontal accumulation and 1/25 of vertical accumulation was produced. The experimental equipment was classified into channels and a flow rate supply and an underwater pump were installed to enable flow at a maximum of 2.0 m3/s. The experimental inflow was 1.3 m3/s, the upstream water level was 0.36 m, downstream water level was 0.24 m, and a cylinder wooden baffle, a dissipater, with a diameter of 0.05 m was made. A 3D scanner was also used for an accurate scour depth comparison for a length change of the baffle before and after installing the baffle. When the baffle was arranged in the shape of a V, the depth of scour decreased by 36% while the scour length decreased by 49% due to flow reduction compared to that before installing the baffle.

Characteristics of Water Quality Parameters of Han River Related to THMs Formation in Water Treatment Plants in Seoul (서울시 정수장의 THMs 생성과 관련된 한강 원수의 주요 수질 특성 조사)

  • Lee, Jin-Hyo;Lee, Ki-Seon;Hwang, Dong-Hyun;Lee, Man-Ho;Han, Sun-Hee;Park, Yong-Sang;Lee, Mok-Young;Lee, Jin-Sook;Koo, Ja-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.886-892
    • /
    • 2011
  • In a study on THMs formation at the distribution facilities in Seoul water supply for past 3 years from 2007 to 2009, THMs production was increased from inlet to outlet during the process in water treatment plant. However, such increased THMs amount was very small compared to THMs production formed after pre-chlorination and post chlorination. Accordingly, this study is aimed to investigate the characteristics of water quality parameters of Han River related to THMs formation in 6 water treatment plants in Seoul. The results showed that THMs and other factors such as temperature (r = 0.539~0.846) and turbidity (r = 0.421~0.863) had positive correlation while THMs had negative correlation with pH (r = -0.613~-0.800) and algae (r = -0.582~-0.901). There is no correlation between THMs and $NH_3-N$. According to the factor analysis, generally metabolite and organic matter factor $X_1$ (pH, BOD, algae), and seasonal and natural factor $X_2$ (temperature, turbidity) played an important role in the formation of THMs. Multiple regression analysis for THMs formation showed significance of regression appeared in most water systems.

The Life Cycle of Tour Destination Hot Spring in Korea (한국 온천관광목적지의 수명주기)

  • Cho, Sung-Ho;Lee, Kyung-Ja
    • Journal of the Korean association of regional geographers
    • /
    • v.4 no.2
    • /
    • pp.165-182
    • /
    • 1998
  • When tour site is being used by people for the destination of tour, it has a life, or it will lose its life as a tour site. Therefore this paper aims to, based on Butler's theory, has chosen 46 hot spring spots in Korea which are legally assigned and presently running, and tried to analyze the life cycles, the stage of dispositional characteristics, and visitors' favoritism, and to try to find activating method which is not decline. Out of 46 spots, 29 Places were found on the stage of development, which took high percentage, 4 were on the growing stage, 5 were on the mature stage, 5 were on the stagnation or decline stage and the rest 3 were on the stage of rejuvenation. Geographically, Korean hot springs were located on the plain or mountainous areas mostly, and less of them were on hills and coast lines. In water quality, most of places had simple water while the places with salt and sulfur contained water were marked low rate. The temperatures of hot spring water were variable between $25^{\circ}C{\sim}78^{\circ}C$, but the older hot springs were hotter than new ones. After observing the relationship between disposition characteristics and life cycles, the geographical locations and the matter of approach were found as majour influential factors to the life cycles of them. The type of mountainous areas were observed slow progress in life cycle, due to traffic problem, until the road expansion or pavement work were done. Meanwhile, the suburban ones adjacent to big cities were favored by hot spring tourists due to their easy approach and easy traffic. The new born hot springs with such conditions have shown the fast growth. As studied above, since the hot springs were supposed to be for recuperation and vacational, a hot spring with better recreational and accommodational facilities was more favored by tourists than the one with pretty interior decorations. It was because the tour purpose of people has been switched from single purpose to multi one. Thus, the suggestion for activating a declining hot spring and bringing people in them is to develop new and attractive tour resources, expanding the related area, maintaining good quality of water, developing a complex site for long-term tour, developed traffic routs, hot spring festivals, utilizing adjacent tour resources, preparing public water supply system, and assigning as special tour zone.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study on the Health Care Satisfaction and Attitude of Elementary School Students - by the presence or absence of nurse teacher - (초등학생의 보건관리 만족도와 태도에 관한 연구 - 양호교사 유무를 중심으로 -)

  • Park, Dong-Kwon;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.49-71
    • /
    • 2000
  • The purpose of this study was to serve as a basis for school health care of better quality, by making a comparative analysis of the health care satisfaction and attitude of elementary school students in consideration of their general characteristics and the presence or absence of nurse teacher. The subjects in this study were 919 selected six graders in 16 elementary schools in the city of Tongduchun, Koyang and Euijungbu, Yangju-kun and Yeunchun-kun. A survey was conducted with questionnaire designed for measurement of health care satisfaction and attitude. As a result of analyzing the data collected from June 1 through 15, 2000, the conclusions were as follows. 1) As for the general characteristics of the students investigated, the subjects included 513 boys(55.8%) and 406 girls(44.2%). The schools where 390(42.4%) students attended were located in municipal area, and the schools where 529(57.6%) students attended were located in kun area. 608(66.2%) students had a nurse teacher at their schools, while 311(33.8%) students had no nurse teacher. 498(54.2%) had an experience to use the health room this year, but 421(45.8%) had no such an experience. Their mean school life satisfaction was scored $3.42{\pm}.71$, above the average. And their health condition was rated $3.81{\pm}.87$, which implied they tended to be in good health. 2) The mean satisfaction at the health room operation was scored $3.33{\pm}.71$, above the medium level. What they were most satisfied with($4.02{\pm}1.08$) was, among the health room facilities, that there were beds. But they expressed the least satisfaction($2.83{\pm}1.17$) at the location of health room. The presence or absence of nurse teacher made a significant difference to their satisfactionat health room operation, because the students in schools with nurse teacher showed greater satisfaction($3.42{\pm}.72$) than the others in schools with no nurse teacher did($3.15{\pm}.66$). 3) Concerning their attitude to use the health room in case of disease or accident occurrence, a lot of students in schools with a nurse teacher, who had ever suffered from indigestion, headache or traumatic injury, used the health room. In schools with no nurse teacher, there was a tendency to talk to their class teachers(p<.001). The recognition of the necessity for health counseling was generally on a medium level. The counselor whom they wanted to discuss health problem with was family or friend in the largest cases. Few students discussed with class teachers in case there was a nurse teacher in school. Instead, some of them discussed with friend, family or nurse teacher, and there was a significant difference between them(p<.001). 4) The mean satisfaction at health, sanitation and environmental management was rated $3.20{\pm}.90$, above the average. The classroom lighting gave them the best satisfaction with $3.67{\pm}1.07$, but the satisfaction at toilet cleanness and disinfection was not good with $2.83{\pm}1.19$. By the presence or absence of nurse teacher, those who had a nurse teacher expressed better satisfaction at water supply facilities including hot water than the others who had no nurse teacher did(p<.001). But no significant difference was observed in the other items. 5) The health education satisfaction was rated $3.19{\pm}.99$, which was on a medium level. By item, the mean satisfaction level was $3.36{\pm}1.19$ at nurse teacher's explanation about treatment, $3.13{\pm}1.15$ at the frequency of health education, and $3.08{\pm}1.16$ at the explanation on the cause of disease. By the presence or absence of nurse teacher, the students with nurse teacher showed significantly better satisfaction at every factor0(p<.001). 6) Regarding health education attitude, their recognition of the need for school health education was scored $3.89{\pm}.96$. Those who had a nurse teacher felt it more necessary($3.96{\pm}.92$), yet the others who had no nurse teacher felt its necessity a little less($3.74{\pm}1.01$). The most preferred thing for them to learn in health education was first aid, followed by sex education, obesity prevention, safety accident prevention in school and outdoors, smoking-related health, good use of leisure time, and environmental pollution cause in the order named. According to the presence or absence of nurse teacher, there was a significant difference in sex education(p<.01), but no significant disparities were found in the other factors. The most preferred person who would offer health education was a lecturer from the outside(45.8%) and nurse teacher(45.4%). Their preference for class teacher as a person in charge of health education was just 8.8%. But the presence or absence of nurse teacher didn't produce any differences to their preference for a person in charge of health education.

  • PDF

Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor (폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.85-95
    • /
    • 2018
  • In this research, a biofilter system equipped with a biofilter process and a humidifier composed of a fluidized aerobic and an anoxic reactor, was constructed to treat odorous waste air containing hydrogen sulfide, ammonia and VOC, frequently generated from pig and poultry housing facilities, compost manufacturing factories and publicly owned facilities. Its optimum operating condition was revealed and discussed. In the experiment of complex feed, the ammonia of fed-waste air was removed by ca. 75% and more than 20% at the stage of the humidifier and the biofilter, respectively. The toluene of the fed-waste air was removed by ca. 20% and more than 70% at the stage of the humidifier and the biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of the humidifier and the biofilter, respectively. In addition, hydrogen sulfide was almost absorbed at the stage of the humidifier so that it was not detected at the biofilter process. In the experiment of ammonia-containing feed, the ammonia of fed-waste air was removed by ca. 65% and 35% at the stage of the humidifier and the biofilter, respectively. Its removal efficiency of ammonia at the stage of the humidifier was 10% less than that in the experiment of complex feed, due to no supply of such carbon source as toluene required in the process of denitrification. In the experiments of complex feed, ammonia-containing feed with and without (instead, glucose) the addition of yeast extract, the absorption rates of ammonia-nitrogen were ca. 0.28 mg/min, 0.23 mg/min and 0.27 mg/min, respectively. The corresponding denitrification rates in the anoxic reactor were 0.42 mg/min, 0.55 mg/min and 0.27 mg/min, respectively. In addition, in the modeling of bubble column(the fluidized aerobic reactor of the humidifier) process, the value of specific surface area(a) of bubbles multiplied by enhanced mass transfer coefficient (E $K_y$) was evaluated to be 0.12/hr.

Solid Waste Disposal Site Selection in Rural Area: Youngyang-Gun, Kyungpook (농촌지역 쓰레기 매립장 입지선정에 관한 연구 -경상북도 영양군을 사례로-)

  • Park, Soon-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.1
    • /
    • pp.63-80
    • /
    • 1997
  • This study attempts to establish the criteria of site selection for establishing solid waste disposal facility, to determine optimal solid waste disposal sites with the criteria, and to examine the suitability of the selected sites. The Multi-Criteria Evaluation(MCE) module in Idrisi is used to determine optimal sites for solid waste disposal. The MCE combines the information from several criteria in interval and/or ratio scale to form a single index of evaluation without leveling down the data scale into ordinal scale. The summary of this study is as follows: First, the considerable criteria are selected through reviewing the literature and the availability of data: namely, percent of slope, fault lines, bedrock characteristics, major residential areas, reservoirs of water supply, rivers, inundated area, roads, and tourist resorts. Second, the criteria maps of nine factors have been developed. Each factor map is standardized and multiplies by its weight, and then the results are summed. After all of the factors have been incorporated, the resulting suitability map is multiplied by each of the constraint in turn to "zero out" unsuitable area. The unsuitable areas are discovered in urban district and its adjacencies, and mountain region as well as river, roads, resort area and their adjacency districts. Third, the potential sites for establishing waste disposal facilities are twenty five districts in Youngyang-gun. Five districts are located in Subi-myun Sinam-ri, nine districts in Chunggi-myun Haehwa-ri and Moojin-ri, and eleven districts in Sukbo-myun Posan-ri. The first highest score of suitability for waste disposal sites is shown at number eleven district in Chunggi-myun Moojin-ri and the second highest one is discovered at number twenty one district in Sukbo-myun Posan-ri that is followed by number nine district in Chunggi-myun Haehwa-ri, number seventeen and twenty three in Sukbo-myun Posan-ri, and number two in Subi-myun Sinam-ri. The first lowest score is found in number six district in Chunggi-myun Haehwa-ri, and the second lowest one is number five district in Subi-myun Sinam-ri. Finally, the Geographic Information System (GIS) helps to select optimal sites with more objectively and to minimize conflict in the determination of waste disposal sites. It is important to present several potential sites with objective criteria for establishing waste disposal facilities and to discover characteristics of each potential site as a result of that final sites of waste disposal are determined through considering thought of residents. This study has a limitation of criteria as a result of the restriction of availability of data such as underground water, soil texture and mineralogy, and thought of residents. To improve selection of optimal sites for a waste disposal facility, more wide rage of spatial and non-spatial data base should be constructed.

  • PDF

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.