• Title/Summary/Keyword: Water Supply Facilities

Search Result 416, Processing Time 0.028 seconds

A Study on Functionality Evaluation of Profit Model for Remodeling of Apartment House (공동주택 리모델링을 위한 수익모델의 기능성 평가 연구)

  • An, Min-Jae;Pyo, Jin-Myung;Kim, Eui-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.107-113
    • /
    • 2005
  • This study analyzes remaining repair rate and applied repair rate with the presentation of profit model for the purpose of pursuing maximization of added value through remodeling of apartment house. Objects of remodeling and item applying the whole replacement of functionality evaluation items include exterior of building (3 items maintaining the current conditions, 8 items requiring the whole replacement), water supply/sanitary/gas/ventilation facilities (6 items maintaining the current conditions, 6 items requiring the whole replacement, electric/fire fighting/elevator facilities (8 items maintaining the current conditions, 20 items requiring the whole replacement) and heating/water heater facilities (2 items requiring the whole replacement).

Forecasting the Long-term Water Demand Using System Dynamics in Seoul (시스템 다이내믹스법을 이용한 서울특별시의 장기 물수요예측)

  • Kim, Shin-Geol;Pyon, Sin-Suk;Kim, Young-Sang;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.187-196
    • /
    • 2006
  • Forecasting the long-term water demand is important in the plan of water supply system because the location and capacity of water facilities are decided according to it. To forecast the long-term water demand, the existing method based on lpcd and population has been usually used. But, these days the trend among the variation of water demand has been disappeared, so expressing other variation of it is needed to forecast correct water demand. To accomplish it, we introduced the System Dynamics method to consider total connections of water demand factor. Firstly, the factors connected with water demand were divided into three sectors(water demand, industry, and population sectors), and the connections of factors were set with multiple regression model. And it was compared to existing method. The results are as followings. The correlation efficients are 0.330 in existing model and 0.960 in SD model and MAE are 3.96% in existing model and 1.68% in SD model. So, it is proved that SD model is superior to the existing model. To forecast the long-term water demand, scenarios were made with variations of employment condition, economic condition and consumer price indexes and forecasted water demands in 2012. After all scenarios were performed, the results showed that it was not needed to increase the water supply ability in Seoul.

A Study on Water Demand Forecasting Methods Applicable to Developing Country (개발도상국에 적용 가능한 물수요 예측 방법 연구)

  • Sung-Uk Kim;Kye-Won Jun;Wan-Seop Pi;Jong-Ho Choi
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.75-84
    • /
    • 2023
  • Many developing countries face challenges in estimating long-term discharge due to the lack of hydrological data for water supply planning, making it difficult to establish a rational water supply plan for decision-making on water distribution. The study area, the Bandung region in Indonesia, is experiencing rapid urbanization and population concentration, leading to a severe shortage of freshwater. The absence of water reservoir prediction methods has resulted in a water supply rate of approximately 20%. In this study, we aimed to propose an approach for predicting water reservoirs in developing countries by analyzing water safety and potential water supply using the MODSIM (Modified SIMYLD) network model. To assess the suitability of the MODSIM model, we applied the unit hydrograph method to calculate long-term discharge based on 19 years of discharge data (2002-2020) from the Pataruman observation station. The analysis confirmed alignment with the existing monthly optimal operation curve. The analysis of power plant capacity revealed a difference of approximately 0.30% to 0.50%, and the water intake safety at the Pataruman point showed 1.64% for Q95% flow and 0.47% for Q355 flow higher. Operational efficiency, compared to the existing reservoir optimal operation curve, was measured at around 1%, confirming the potential of using the MODSIM network model for water supply evaluation and the need for water supply facilities.

Influences of pH on Heavy Metal Leaching in Water Supply Pipelines (상수도관내 중금속 용출에 대한 수소이온농도의 영향 평가 연구)

  • Lee, Jeongwon;Noh, Yoorae;Park, Joonhong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.73-82
    • /
    • 2017
  • In Korea, previous certification of water supply infrastructure was mainly focused on economical and physical aspects. Recently, hygienic safety of water supply service has become a sensitive and important issue to our people for evaluating the water quality with growth of economy and education system. According on water quality in 497 Korean water supply facilities, pH values in the supplied water have ranged between 5.8-8.5. However, little is known about metal leachability at the pH conditions observed in the real water supply systems because a fixed pH condition (pH 7.0) has been used in the current standard method, 'Hygienic Safety Testing Method', in water supply. In this work, we examined the effects on heavy metal leachability with pH differences in the water supply pipes which are typically used in Korea. As a result, the amounts of metal leachability were tended to increase when pH levels were decreased. Especially at pH 5.8, Cu leachability from Cu pipes was found to exceed the public health standard level even after applying a normalization factor (NF) given by the current Korea standard method. The Cr and Cu leached from stainless steel pipes, Cd, Pb, Cu, and Zn from Cu-based pipe fittings, and Zn from Zn-based pipe fittings were exceeded the Korean hygienic safety standards while, after applying the NF, concentrations of the leached metals were satisfied with the current Korean standard. The findings from this work provide implications on the needs of reforming the current hygienic safety standard methodology.

A survey on the application of ICTs in automated water level gauges for agricultural reservoirs

  • Min-Gi Jeon;Jin-Taek Kim;Won-Ho Nam
    • Korean Journal of Agricultural Science
    • /
    • v.51 no.2
    • /
    • pp.217-225
    • /
    • 2024
  • Timely and appropriate water supply to paddy fields is crucial for efficient agricultural water management. In South Korea, 17,240 agricultural reservoirs supply approximately 60% of the agricultural water and play a pivotal role in irrigation and drought mitigation. These reservoirs are managed by the Korea Rural Community Corporation (KRC), which oversees 3,411 reservoirs, and various local governments, which manage 13,829 locations. Guidelines from the Ministry of Agriculture, Food and Rural Affairs (MAFRA) mandate the installation and operation of water level measurement instruments. Currently, automated water level facilities are installed in 1,734 reservoirs and 1,880 irrigation canals, generating water level data at ten-minute intervals. In this study, a survey was conducted to enhance the management of agricultural reservoirs by integrating advanced information and communications technology (ICT) into existing automated water level gauge systems. We propose directions for enhancing the automated water level gauges in agricultural reservoirs. The findings would provide foundational data for stable and systematic management of these gauges.

Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants (공공하수처리시설 수질기준 선진화 방안)

  • Yu, Soon-Ju;Park, Sang-Min;Kwon, Oh-Sang;Park, Su-Jeong;Yeom, Ick-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.

Implication of the Saemaul Undong on water resources development in rural communities during 1970's (농촌지역 수자원개발에 있어 새마을 운동의 역할과 의의에 대한 실증적 연구)

  • Hwang, Junshik;Seo, Yongwon;Jung, Jin Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.699-705
    • /
    • 2016
  • Although it has been well known that the Saemaul Undong had a direct relation with the water resources development during 1970's, its contribution to the water resources and increased income in rural communities has not been thoroughly quantified so far. In order to assess the contribution of the Saemaul Undong in terms of rural water resources development, we investigated various historical data produced by the central and local governments in relation to water resources development. The results show the direct and indirect contribution of the Saemaul Undong to the water resources development in rural communities such as sewage works, water supply facilities, shared wells, and river works. The results also showed a positive relation between per-house income in rural communities and areas of irrigated paddies, which were rapidly increased during 1970's. These results can be utilized to transplant the positive aspect of the Saemaul Undong to developing countries focusing on water resources development in rural areas.

A Study on the Pollution Sources of Simple water Supply Piped System using Statistical Analysis (통계적 분석을 이용한 간이급수시설의 오염원에 관한 연구)

  • 이홍근;김현용;백도현;김지영;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.2
    • /
    • pp.56-67
    • /
    • 1999
  • This study was performed to suggest the basic data and plans for the establishment of safe water supply plans in simple water supply piped system in the rural areas. In 4 different places, 24 points of water sources 36 points of taps from water sources were sampled. Of the whole 60 points, 55 points were ground water and 5 points were surface water. 14 items were measured for the analysis of water quality on each samples. The measured items were analyzed again by statistical method ; cluster analysis and principle components analysis. The results of this study are as followed. 1) In water quality analysis on water sources, 4 items, bacteria, E.coli, NH3-N and Fe exceed the standard. Of 24 points, 20 points(83%) on bacteria, 1 point(4%) on NH3-N and Fe exceed the standard. 2) In water quality analysis on near and remote taps, 4 items, bacteria, E.coli, NH3-N and Fe , exceed the standard. Of 36 points, 20 points (81%) on bactria, 1 pint(3%) on NH3-N and Fe exceed the standard. 3)Cluster analysis on water quality shows the differences by the kinds of water sources, geographical characteristics and distance from water sources. 4) Principle components analysis on ground water shows that Factor 1 and Factor 3 are natural fluctuation by the content of soil. Also, Factor 2 and Factor 4 are penetration of pollutants to underground. Therefore, it is needed to take deeper ground water in order to prevent from pollution in the areas which have ground water as water source . 5) Principle components analysis on surface water shows that Factor 1 is penetration of vacteria from surface to water source when rainfalls. Also, Factor 2 is fluctuation of water quality by the geographical characteristics. Therefore, the counterplans against non-point pollution source must be taken. Filtration and disinfection facilities are needed in the areas which have surface water as water source.

  • PDF

Marginal Benefit-Cost Analysis of Irrigation Water in Rice Production (미곡생산(米穀生産)에 있어서 관개용수(灌漑用水)의 한계편익(限界便益)·비용분석(費用分析))

  • Lim, Jae-Hwan;Lee, Min-Soo
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.2
    • /
    • pp.132-146
    • /
    • 2001
  • Rice cultivation is not only the main resource of farm income and staple food but also the root of cultural life of Korean people. Korean government has carried out irrigation water development with heavy investment to cope with water shortage in rice fanning as a link of the five years economic development plans. In spite of the continuous accomplishment of irrigation water development, the marginal benefits-costs of irrigation water has not been studied. Owing to the government full support for the operation and maintenance of irrigation facilities, price of irrigation water as a membership fee could not be formed as the municipal and industrial water prices. Accordingly this study is aimed at identifying firstly the marginal benefits-cost of irrigation water, secondly deriving the macro-econometrics models as supply and demand functions of irrigation water and thirdly examining the marginal benefits-cost ratio. The trends of supply and demand prices of irrigation water were estimated annually. Considering the marginal benefits-cost ratio as 1.3, it was identified that additional irrigation water development projects still have an economic feasibility under the present economic situation in Korea.

  • PDF

Revealing Geography of Water in Taebaek City through Actor-Network Theory (행위자-연결망 이론을 통해서 본 태백시 물 공급의 지리학)

  • Kim, Na Hyeung;Kim, Sook-Jin
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.3
    • /
    • pp.366-386
    • /
    • 2013
  • This paper analyzes the drought and restriction on water supply in Taebaek City during the winter season in 2008 using Actor-Network Theory. Actor-Network Theory emphasizes and brings into view the role and act of non-human actors as well as human actors in various environmental issues. The fact that only Taebaek experienced restriction on water supply for 88 days although the winter season drought in 2008 affected the whole nation, requires a synthetic analysis of both human and non-human actors and their relationships and networks embedded in Taebaek City at that time. This paper shows that both human and non-human actors including Taebaek City Hall, Korea Water Resource Corporation, Taebaek citizen, the water supply facilities, Gwangdongdam, obsolete water pipes, the topography of Taebaek, soil, the change of industry, and population interact one another transforming the geography of water in Taebaek. This study helps to understand the complex processes related to drought disasters at a specific local scale and to provide appropriate measures to drought.

  • PDF