• 제목/요약/키워드: Water Supply Facilities

검색결과 417건 처리시간 0.069초

Comparison of Alternatives of Water-Friendly Facilities in an Industrial Complex (산업단지내 친수시설 대안의 비교)

  • Chung, Sang-Ok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.1570-1576
    • /
    • 2008
  • Construction of the water-friendly facilities in the apartment complex and industrial complex became popular these days. In planning water-friendly facilities, kinds, layouts, water sources, water quality and water circulation system should be studies. In this study, several alternatives for a regional industrial complex project were studies and a most reasonal alternative was selected. A main canal across the central part of the complex is the principle facility with ponds and parks. The water source alternatives were a river nearby, a reservoir, ground water and urban water supply system. For each system, water quantity and quality, circulation system, permit and maintenance were compared. The facilities should be constructed with natural material such as rock and gravel. Average depth and velocity in the canal should be 10 cm and 0.15 m/s, respectively in order to people can feel the water flow in the canal. Based on the comparison, it is found that using the ground water, and water circulation system with storage tanks at the upper and lower ends of the canal system is the best alternative.

  • PDF

A Study on Geo-Spatial Information System Database Establishment for Urban Information Analysis -With Emphasis on Water Supply Facilities- (都市情報解析을 위한 地形空間情報體系의 資料基盤部 構築에 關한 硏究 -上水道 施設物管理 中心으로-)

  • Yeu, Bock-Mo;Youn, Kyung-Chul;Choi, Chul-Soon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • 제10권2호
    • /
    • pp.31-36
    • /
    • 1992
  • Geo-Spatial Information Systems(GSIS) are being used in various urban municipalities as a tool in decision making. Efforts are being made to implement geo-spatial information system databases to systematically and effectively carry out planning, management and monitoring in various fields. This study is about the database establishment of geo-spatial information systems. The study was then applied to water supply facilities management, where the functions and data used in water management were identified through system analysis and the geo-spatial database was designed based on this analysis. Also four application programs were developed to support departments which used various maps and drawings.

  • PDF

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Proceedings of the SAREK Conference
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.510-515
    • /
    • 2007
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows ; 1) On the whole, typical rates of water-use was founded out 15 L / stu. d in pirmary school, 10 L / stu. d in middle school and 30L / stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking pick load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

  • PDF

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • 제38권5호
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

The deployment Advanced Technology of Water supply line breakage detection system in Songsan Green City (송산그린시티(동측)내 선진 상수관로파손감시시스템 구축기술)

  • Kwag, Jun keun;Park, Ji Young;Yoon, Sang Jo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.291-295
    • /
    • 2022
  • This paper deal with the advanced thchnology of water supply line breakege detection system in singsan green city. the technology apply for construction eco oriented high-tech city to merge residant, industial, tour reasure parts for songsan green city furture direction achivement and response for a life style change of people in the city. Breakege detection system consist of smart prevention seat, pipeline breakege detection sensor, analysis software, server. etc.. Central control unit sent the data to hwa sung city water supply office by WCDMA in SKY. the data are states about water supply pipeline, Location.etc. This system maintain the long term life cycle of water supply plpeline by the prevention the leakege event through ackonwledge information of evnet occurrence locaion. and used to realtime sense method about demage information of the pipeline and prevent to brekege facilities during excavation work.

  • PDF

Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province (제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제32권6호
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

A Field Study on the Facilities and Equipments of the Traditional Farmhouse in Lungching, China (중국 연변 조선족 전통농가의 시설설비 실태조사)

  • 고도임
    • Journal of the Korean Home Economics Association
    • /
    • 제36권6호
    • /
    • pp.123-132
    • /
    • 1998
  • This paper is a part of "The Study of the Traditionla Korean Ethnic Farmhousing in Yanbian, China" The purpose of this study is to investigate the facilities and equipments of the traditional farmhouse in the villages of Lungching China. The data is collected from 124 households in the villages based on the survey conducted using questionnaire and photograph. The major findings are: 1) The people in farmhouse use wood as a fuel for cooking and the method of cooking is traditional style using their iron pots. 2) Heating system of the house is ondol type of heating using. wood which is also traditional type. This means that the floor heating of the house and cooking food can be carried out simultaneously. 3) Even though pump system and running water system are the two kinds of water supply that are available in the villages, majority of people use pump system. Many houses have no drainage facilities but few houses have got bad drainage system. 4) From the planning stage of the farm house facilities and equipments for ventilation is not considered and hence it is not provided in most of the houses. 5) Farmhouses are oriented to the south and the windows and the doors are covered either with viny1 or cloth during winter time effecting the lighting system of the house. 6)Many of the houses use incandescent lights. But the switchs and the electric Outlets are short in number. 7) Sanitation facilities are worst equipped compared to other facilities present in Lungching villages of China. of China.

  • PDF

Assessment of GHG Reduction Strategy - A Case of Environmental Facilities of Incheon City - (온실가스 감축 전략의 성과평가 - 지자체 환경기초시설 사례 -)

  • Jang, Jong-Ok;Lee, Sung Wook;Kim, Jong Dae
    • Journal of Environmental Science International
    • /
    • 제26권4호
    • /
    • pp.509-519
    • /
    • 2017
  • The study focuses on 32 environmental facilities in Incheon Metropolitan City, South Korea, categorizes them by sector: sewage treatment, wastewater treatment, incineration, landfill, water purification, and water supply. Their GHG reduction results are analyzed through quantitative and qualitative measures for 2012 to 2015. The study surveys and examines GHG reductions of the environmental facilities for two categories - facility operation and management. The findings are as follows: First, the GHG reduction rate, an emission-to-allocation ratio, from 2012 to 2015 is 89.67%. Second, GHG reductions coming from qualitative measures of facility management are even greater than those from quantitative measures of facility operation. Third, GHG reductions through facility operation are mostly attributable to overhauls, less use of facilities, resources recycling, process improvement rather than the betterment of fuels, facilities and energy efficiency. Fourth, higher reduction can be achieved by effective facility management, qualitative measures.

Nitrate Contamination of Shallow Groundwater in an Agricultural area having Intensive Livestock Facilities (축사가 밀집된 농촌지역 천부지하수의 질산염 오염특성)

  • 김연태;우남칠
    • Journal of Soil and Groundwater Environment
    • /
    • 제8권1호
    • /
    • pp.57-67
    • /
    • 2003
  • Nitrate contamination by human activities is a serious problem to water-supply in agricultural area. Shallow groundwater is the main source of water-supply, but it is very sensitive to contamination. Study area for nitrate contamination is a region of Iljuk, Kyunggi where is an agricultural area having many livestock facilities in various scales. As a result, the points having availability of incoming of external contaminant are 77%, and the ones over the Drinking Water Limit (DWL) are 32~42%. For a nitrogen isotope analysis, all the points having availability of incoming of external contaminant have $\delta$$^{15}$ N-NO$_3$ values over 5$\textperthousand$, and the points of 59% are strongly affected by nitrogen originated from animal wastes. The major source of nitrate in this area is intensive livestock facilities. Even though a livestock facility had enclosed, it affects groundwater quality for a long time. The chemical property of contaminant source is various according to animal species in surface water, but not in groundwater since some solutes are removed by reactions during an inflow to subsurface.

Correlation analysis between TOC and organic matter indices in influent and effluent of public sewage treatment facilities (공공하수처리시설 유입수 및 방류수에서 TOC와 유기물질 관리지표간의 상관성 분석)

  • Son, Dong-Jin;Jeong, Dong-Hwan;Park, Kyoo-Hong
    • Journal of Convergence for Information Technology
    • /
    • 제11권4호
    • /
    • pp.122-129
    • /
    • 2021
  • As the total organic carbon (TOC) becomes a new water quality standard as an organic matter (OM) index for public sewage treatment facilities (PSTFs) in Korea from 2021, a comparison study needs to be conducted by examining the correlation between TOC and the existing OM indices (DOC, BOD5, CODMn, CODCr). 500 PSTFs were categorized by process configuration and capacity, and correlation between OM indices in influent and effluent was analyzed. The CODMn/TOC showed higher correlation than other OM indices. This results can be used to basic data for various research associated with TOC.