• Title/Summary/Keyword: Water Sprays

Search Result 46, Processing Time 0.025 seconds

Comparison of the Characteristics of Sprays between Water and Nanofluid Sprays (물과 나노유체의 분무 특성 비교)

  • Kang, B.S.;Lee, S.P.
    • Journal of ILASS-Korea
    • /
    • v.19 no.2
    • /
    • pp.82-87
    • /
    • 2014
  • Nanofluids are that metallic or nonmetallic nanometer-sized particles are dispersed in liquid. They can be used in various fields to increase the heat transfer rate because the thermal conductivity of nanofluids can be increased significantly. Nanofluids may be used as a good alternative of coolants in spray cooling. This study conducted experiments to compare the characteristics of sprays between water and nanofluid sprays. The radial distributions of droplet velocities and diameters of water, 0.2% wt.(weight), and 0.5% wt. $Al_2O_3$ nanofluids at the pressure of 0.2 and 0.3 MPa were measured by laser doppler instruments. The radial distributions of droplet diameters and velocities at two axial positions with water and 0.2% wt. nanofluid sprays didn't show much difference. A big difference, however, was observed between 0.5% wt. nanofluid and water sprays. With the increase of the mass of nano-particles, the average droplet diameters were increased and the average droplet velocities were decreased.

Extingushiment by the Colling Effect of the Fuel Surface with Pool Fires (Pool 화재에서의 표면 냉각에 의한 소화)

  • 한용식;김명배;신현동
    • Fire Science and Engineering
    • /
    • v.11 no.4
    • /
    • pp.15-23
    • /
    • 1997
  • A series of measurements and visualization to investigate the extingushiment of water sprays with pool fires is presented. Fire source is a small-scale pool burner with methanol, ethanol and gasoline. Measurements of temperature, O2, CO2, and CO concentrations along the plume centerline are carried out to observe pool structures without water sprays. Visualization by the Ar-ion laser sheet flow pattern of droplets of the sprays above the pool fires. It is observed than in the case of methanol and ethanol, water sprays continuously penetrate into the center of fuel surfaces. The gasoline pool fire allows intermittent penetration of water sprays because of pulsating characteristics of the gasoline flame. To evaluate the cooling effect of the fuel surface by the sprays, the temperature was measured at the fuel surface. As soon as the mists reach the fuel surface of methanol and ethanol, the temperatures of the fuel surface decrease rapidly below the boiling point, and then the fires are extinguished. Due to the application of mist upon the gasoline fire, though the fuel temperature decrease abruptly at the time of the injection, such a repid decrease do not continue till the extinction point.

  • PDF

EXPERIMENTS ON THE INTERACTION OF WATER SPRAYS WITH POOL FIRES

  • Han, Yong-Shik;Kim, Myung-Bae;Shin, Hyun-Dong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.518-525
    • /
    • 1997
  • A series of measurements and visualization to investigate the interaction of water sprays with pool fires is presented. Fire source is a small-scale pool burner with methanol, ethanol and gasoline. Measurements of temperatures, $O_2$, $CO_2$, and CO concentrations along the plume centerline are carried out to observe pool fire structures without water sprays. Visualization by the Ar-ion laser sheet shows flow pattern of droplets of the sprays above the pool fires. It is observed that in the case of methanol and ethanol, water sprays continuously penetrate into the center of fuel surfaces. The gasoline pool fire allows intermittent penetration of water sprays because of pulsating characteristics of the gasoline flame. To evaluate the cooling effect of the fuel surface by the sprays, the temperature was measured at the fuel surface. As soon as the mists reach the fuel surface of methanol and ethanol, the temperatures of the fuel surface decrease rapidly below the boiling point, and then the fires are extinguished. Due to the application of mist upon the gasoline fire, though the fuel temperature decrease abruptly at the time of the injection, such a rapid decrease do not continue till the extinction point.

  • PDF

Effects of Water-misting Sprays with Forced Ventilation after Transport during Summer on Meat Quality, Stress Parameters, Glycolytic Potential and Microstructures of Muscle in Broilers

  • Jiang, N.N.;Xing, T.;Wang, P.;Xie, C.;Xu, X.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.12
    • /
    • pp.1767-1773
    • /
    • 2015
  • Effects of water-misting sprays with forced ventilation after transport during summer on meat quality, stress parameters, glycolytic potential and microstructures of muscle in broilers were investigated. A total of 105 mixed-sex Arbor Acres broilers were divided into three treatment groups: i) 45-min transport without rest (T group), ii) 45-min transport with 1-h rest (TR group), iii) 45-min transport with 15-min water-misting sprays with forced ventilation and 45-min rest (TWFR group). The results showed the TWFR group significantly increased (p<0.05) initial muscle pH ($pH_i$) and ultimate pH ($pH_u$) and significantly reduced $L^*$ (p<0.05), drip loss, cook loss, creatine kinase, lactate dehydrogenase activity, plasma glucose content, lactate and glycolytic potential when compared with other groups. Microstructure of the muscle from TWFR group broilers under light microscopy showed smaller intercellular spaces among muscle fibers and bundles compared with T group. In conclusion this study indicated water-misting sprays with forced ventilation after transport could relieve the stress caused by transport under high temperature, which was favorable for the broilers' welfare. Furthermore, water-misting sprays with forced ventilation after transport slowed down the postmortem glycolysis rate and inhibited the occurrence of PSE-like meat in broilers. Although rest after transport could also improve the meat quality, the effect was not as significant as water-misting sprays with forced ventilation after transport.

Characterization of Sprays used Ultrasonic Vibrant Plate with the Surface roughness (초음파 진동판의 표면조도에 따른 분무특성에 관한 연구)

  • Lee, Jun-Baek;Jeon, In-Kon;Jeon, Heung-Shin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.732-737
    • /
    • 2000
  • The purpose of this study is to compare the SMD(Sauter mean diameter) with different vibrant plates. Each vibrant plates have different surface roughness. Also liquid film thickness are measured for explanation how to concern atomization. Ultrasonic waves is used for vibration. Immersion liquid method is used for the measure of SMD and also liquid film thickness is measured using of point needle method. Distilled water and gasoline fuel are used to liquids. Supplied liquid flow rates are $18{\sim}296cc/min$. Centerline average roughness of vibrant plates are 0.5, 2.0, 4.7, $9.5\;{\mu}m$ and diameter of vibrant plate is 60mm. In result, good atomization of liquid is obtained in widen flow rates. The mean droplet size is increased in orders of 4.7, 2.0. 9.5, $0.5\;{\mu}m$ surface roughness. Distilled water has a big mean droplet size than gasoline fuel in low flow rate. Above the 78cc/min flow rates, distilled water has a small mean droplet size than gasoline fuel. Liquid films changes are measured with ultrasonic power. Also, cavitation effect on sprays is observed.

  • PDF

Effects of Spray Surfactant and Particle Charge on Respirable Coal Dust Capture

  • Tessum, Mei W.;Raynor, Peter C.
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.296-305
    • /
    • 2017
  • Background: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. Methods: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. Results: The diameter of the tested coal dust aerosol was $0.89{\mu}m{\pm}1.45$ [geometric $mean{\pm}geometric$ standard deviations (SD)]. Respirable particle mass was collected with $75.5{\pm}5.9%$ ($mean{\pm}SD$) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. Conclusion: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

Effect of liquid viscosity on the degree of uniformity of drops from swirl spray nozzles (와류 분무 노즐에 의해 형성되는 액적들의 균일도에 액체의 점도가 미치는 영향)

  • 이상용;김인구;조한권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.538-546
    • /
    • 1989
  • Effect of liquid viscosity was studied experimentally on the drop size distributions of the liquid sprays from swirl atomizers. Glycerine-Water mixtures were used as test fluids for the experiments. Drop sizes of the liquid sprays were measured with the light scattering method. The concept of the standard deviation was introduced to represent the degree of uniformity of the drop size distributions. Experimental results show that the spray drops become coarser and less uniform with the liquid of higher viscosity. The effect of viscosity on the Sauter mean diameter and the standard deviation appeared to be more significant with the lower injection pressure. It was also confirmed that the Sauter mean diameter increases with the increase of the liquid viscosity and with the decrease of the injection pressure.

Insecticidal Effect of Neem Cake Extracts on Cabbage Pests, Aphis gossypii and Pluetella xylostella

  • Lee. HoYong;Kim, Won-Rok;Min, Bong Hee
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.4
    • /
    • pp.501-506
    • /
    • 2004
  • In organic agriculture, choose of effective and cheap bio-pesticide is very important. The authors developed an insecticidal extract from neem cake, waste of neem oil from kernel, and applied as a bio-pesticide. Bio-pesticide neem cake extracts experiment on cabbage pest was carried out at Wonju Agricultural Technology and Extension Center from 11 March to 30 May 2003. There were six treatments with three replications, using completely randomized design. Treatments involved three and six sprays of synthetic pyrethroid pesticide cypermethrin 10 EC at the dilution rate of 2.2 mL $L^{-1}$ of distilled water and four, five and six sprays of bio-pesticide neem at the dilution rate of 13.3 mL $L^{-1}$ of distilled water, and untreated control. For each treatment, designated sprayings were done at 7 days interval. Pre-spray data showed that the plants in all the experimental plots were already infested with aphid (Aphis gossypii), and diamondback moth (Pluetella xylostella). The results indicated that all neem pesticide treatments were more effective in insecticidal activity than the untreated control and the chemical treatments in controlling aphids and diamondback moth. Among the three neem treatments, there were no significant differences between them.

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

A study on the Water Mist Fire Suppression Performance (미세 물 분무 소화 성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF