• 제목/요약/키워드: Water Resistivity

검색결과 385건 처리시간 0.025초

부산지역의 해저용출수 전기비저항탐사 (Resistivity Exploration of Submarine Groundwater Discharge in Busan Area)

  • 박준규;김성욱;이진혁;김인수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.711-716
    • /
    • 2010
  • This study selected the promising area of submarine groundwater discharge(SGD) that flows into the sea following unconfined physical aquifer through the electrical resistivity survey of the land and sea. The submarine groundwater discharge(SGD) mostly flows into the sea following fracture zones, and the detection of the fault zone becomes the important guideline of groundwater discharge. Electrical sounding of the land assessed the groundwater flow and integration possibility according to the location of a fault that is a water path between underground reservoir and surface water as well as a rock fracture. In addition, the study conducted sea electrical resistivity to expand the area with high potential and selected the expected water potential groundwater area. The areas of the study were Busan and coastal areas, and for the terrain analysis, the candidates of the ground exploration were selected after analyzing lineaments that is expanded to coast direction.

  • PDF

모래의 수분함유량에 따른 비저항 및 비유전율의 주파수 의존성 (Frequency Dependent Resistivity and Relative Dielectric Constant with the Water Contents in Sand)

  • 이복희;차응석;최종혁;최영철;유양우;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.348-351
    • /
    • 2009
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than its ground resistance. Recently, some researches on the evaluation and modeling of the grounding impedances have been carried out but the results have not been yet sufficient. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of sand associated with water contents. As a result, the resistivity of sand is getting lower with increasing water content and it is nearly independent on the frequency in the range of less than 1MHz, and is decreased over the frequency range of above 1MHz. Also, the relative dielectric constant is rapidly decreased with the frequency in the range of less than 10kHz, but it is nearly not dependent on the frequency over the frequency range of 10kHz. It was found from this work that the frequency dependance of resistivity and relative dielectric constant of soil should be considered in designing the grounding systems for protection against lightning or surges.

  • PDF

전기비저항탐사에 의한 제당의 누수구간 탐지 (Delineation of water seepage in earth-fill embankments by electrical resistivity method)

  • 정승환;김정호;양재만;한규언;김영웅
    • 지질공학
    • /
    • 제2권1호
    • /
    • pp.47-57
    • /
    • 1992
  • 파쇄대 및 균열대를 따라 비교적 심부에 분포하는 우리나라 암반 지하수 탐지를 위한 효과적인 물리탐사방법과 농업용 제당의 누수구간 탐지를 위한 소위 비파괴적 탐지방법의 개발을 위한 연구를 실시하였다. 이를 위해 종래 사용하던 1차원적인 수직 비저항탐사(Vertical electrical sounding)보다 2차원적인 수평-수직 탐사를 동시에 수행할 수 있는 쌍극자 비저항배역(dipole-dipole array)탐사법을 이용하는 야외탐사방법의 확립과 획득된 자료의 정량해석을 위한 computer program을 개발하였다. 본 연구에서는 쌍극자배열탐사법과 정량해석 program의 효율성을 검증하기 위해 이미 지질 및 시추조사가 종료된 두 곳의 누수 제당에 대하여 야외탐사를 하였다. 야외조사를 통해 획득된 자료들에 대하여 본 연구를 통해 개발된 program을 활용하였던바, 제당누수구간 및 파쇄대 내지는 단층대내에 발달되는 암반지하수 탐지에 효율적임이 입증되었다. 본 연구에서는 개발된 쌍극자 비저항탐사법과 해석 program은 암반지하수 탐지는 물론 누수제당의 누수구간 탐지 및 안전성 진단 등에 적극 활용할 수 있으리라 판단된다.

  • PDF

The influence of EAF dust on resistivity of concrete and corrosion of steel bars embedded in concrete

  • Almutlaq, Fahad M.
    • Advances in concrete construction
    • /
    • 제2권3호
    • /
    • pp.163-176
    • /
    • 2014
  • Essentially, when electrical current flows easily in concrete that has large pores filled with highly connective pore water, this is an indication of a low resistivity concrete. In concrete, the flow of current between anodic and cathodic sites on a steel reinforcing bar surface is regulated by the concrete electrical resistance. Therefore, deterioration of any existing reinforced concrete structure due to corrosion of reinforcement steel bar is governed, to some extent, by resistivity of concrete. Resistivity of concrete can be improved by using SCMs and thus increases the concrete electrical resistance and the ability of concrete to resist chloride ingress and/or oxygen penetration resulting in prolonging the onset of corrosion. After depassivation it may slow down the corrosion rate of the steel bar. This indicates the need for further study of the effect of electric arc furnace dust (EAFD) addition on the concrete resistivity. In this study, concrete specimens rather than mortars were cast with different additions of EAFD to verify the electrochemical results obtained and to try to understand the role of EAFD addition in influencing the corrosion behaviour of reinforcing steel bar embedded in concrete and its relation to the resistivity of concrete. The results of these investigations indicated that the corrosion resistance of steel bars embedded in concrete containing EAFD was improved, which may link to the high resistivity found in EAFD-concrete. In this paper, potential measurements, corrosion rates, gravimetric corrosion weight results and resistivity measurements will be presented and their relationships will also be discussed in details.

오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가 (Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination)

  • 오명학;김용성;유동주;박준범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF

Prediction model of resistivity and compressive strength of waste LCD glass concrete

  • Wang, Chien-Chih
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.467-475
    • /
    • 2017
  • The purpose of this study is to establish a prediction model for the electrical resistivity ($E_r$) of self-consolidating concrete by using waste LCD (liquid crystal display) glass as part of the fine aggregate and then, to analyze the results obtained from a series of laboratory tests. A hyperbolic function is used to perform nonlinear multivariate regression analysis of the electrical resistivity prediction model, with parameters such as water-binder ratio (w/b), curing age (t) and waste glass content (G). Furthermore, the relationship of compressive strength and electrical resistivity of waste LCD glass concrete is also found by a logarithm function, while compressive strength is evaluated by the electrical resistivity of non-destructive testing (NDT). According to relative regression analysis, the electrical resistivity and compressive strength prediction models are developed, and the results show that a good agreement is obtained using the proposed prediction models. From the comparison between the predicted analysis values and test results, the MAPE value of electrical resistivity is 17.0-18.2% and less than 20%, the MAPE value of compressive strength evaluated by $E_r$ is 5.9-10.6% and nearly less than 10%. Therefore, the prediction models established in this study have good predictive ability for electrical resistivity and compressive strength of waste LCD glass concrete. However, further study is needed in regard to applying the proposed prediction models to other ranges of mixture parameters.

Evaluation of strength characteristics of cement-stabilized soil using the electrical resistivity measurement

  • Kean Thai Chhun;Chan-Young Yune
    • Geomechanics and Engineering
    • /
    • 제33권3호
    • /
    • pp.261-269
    • /
    • 2023
  • In this study, the compressive strength of cement stabilized soil was predicted using the electrical resistivity measurement. The effects of the water to cement (w/c) ratio and recovered Carbon Black (rCB) contents were examined. A series of electrical resistivity and compressive strength tests were conducted on two types of stabilized soil after 28 days of curing. Multiple nonlinear regression (MNLR) analysis was used to evaluate the relationship between the compressive strength and the electrical resistivity in terms of the rCB, Cu (uniformity coefficient), and w/c ratio. The results showed that the w/c ratio and Cu have a strong influence on the compressive strength and electrical resistivity of the cement stabilized soil compared to the rCB content. The use of a small amount of rCB led to a decrease in the void space in the specimen and was attributed to the increase strength and decrease electrical resistivity. A high w/c ratio also induced a low electrical resistivity and compressive strength, whereas 3% rCB in the cemented soil provided the optimum strength for all w/c ratios. Finally, a prediction equation for the compressive strength using the electrical resistivity measurement was suggested based on its reliability, time effectiveness, non-destructiveness, and cost-effectiveness.

수상환경의 대지저항률 및 접지저항 측정의 실험적 연구 (An Experimental Study on Ground Resistivity and Grounding Resistance of Water Environment)

  • 최영관
    • 한국산학기술학회논문지
    • /
    • 제15권4호
    • /
    • pp.2343-2348
    • /
    • 2014
  • 지락사고 시 지락전류에 의한 전위경도 상승으로부터 인체를 보호하기 위하여 발전소의 주 접지망을 구성한다. 이를 위한 접지설계시 일반적으로 IEEE Std-80-2000(한전설계기준 2602)에 의하여 계산한다. 그러나 이는 수상환경에서 적용하기 힘들어 수상태양광의 접지저항 확보를 위한 접지기술이 명확하지 않다. 그런데 500kW 수상태양광의 모듈표면 및 금속덕트에 정전기가 발생하고 있고, 안정적인 접지확보를 위해서는 수상환경의 접지방식에 대한 구체적인 방안이 필요한 실정이다. 따라서 본 논문에서는 수상환경에서 Wenner 4 전극법으로 대지저항률을 조사.분석하였으며, 현재 운영중인 수상태양광의 접지저항을 국제규격(IEEE std-81)에서 제시하는 전압강하법으로 측정 분석하여 안정적인 접지확보를 위한 수상태양광 접지방안을 제시하였다. 수면 1m 수중의 저항률이 ($126.3969[{\Omega}{\cdot}m]$) 하상의 저항률($97.5713[{\Omega}{\cdot}m]$)보다 대체로 높은 것을 측정 분석되었고, 제시한 접지앵커 접지방안은 수상태양광의 더욱 안정된 접지저항 확보를 위해 경제적으로 가장 효과적인 방법으로 판단되며, 향후 수상태양광 발전의 접지방법으로 활용될 것으로 기대된다.

원격탐사, 전기탐사, 전자기탐사 및 시추공영상의 융합적 분석을 통한 서산지역 방조제 누수구역 판별 (Investigation of Water Leakage in Seosan A-Region Sea Wall using Integrated Analysis of Remote Sensing, Electrical Resistivity Survey, Electromagnetic Survey, and Borehole Survey)

  • 홍성인;이동익;백광현;유영철;임국묵;유재형
    • 자원환경지질
    • /
    • 제46권2호
    • /
    • pp.105-121
    • /
    • 2013
  • 본 연구에서는 원격탐사, 전기비저항탐사, 전기전도도탐사(전자기탐사), 시추공 영상촬영법을 융합하여 효과적인 제방의 안정성 및 누수 평가 방법을 서산 A지구 방조제에 적용하여 제시하였다. Landsat ETM+열적외선 밴드를 사용하여 방조제 부근에서 다른 온도의 해수와 담수가 혼합되는 양상을 통해 누수의 존재, 규모 및 기간을 유추하였다. 전기비저항탐사를 방조제를 따라 실시하여 평균비저항 값 83.197 ${\Omega}$-m이하를 보이는 이상대의 수평적 수직적 분포를 확인하였다. 간조와 만조 시의 전기전도도 값의 분석을 통해 배경치의 영향을 최소화한 수평적 이상대 분포를 확인하였다. 시추공영상촬영을 통해 파쇄대의 수직적 분포양상과 기존 탐사법의 정확도를 확인하였다. 그 결과 전체 제방의 연장 중 41.7%에서 세 수평적 이상대 탐사법의 중첩구간이 확인되었으며, 시추공에서 확인된 수직적 파쇄양상을 고려할 때 누수구간이 제방단면의 중심부를 따라 상당부분 수평적으로 연장이 되어 방대한 양의 누수가 존재할 가능성이 높을 것으로 사료된다. 네 탐사법의 융합적 접근은 각 탐사방법이 가지고 있는 장점을 부각하고 단점을 보완하여 수평적 및 수직적인 누수구간과 기간의 확인 및 판별이 가능하고, 시추공에서 확인된 수직적 파쇄양상의 수평적 연장성을 예측하는데 높은 신뢰도를 보인다 할 수 있다.

Monitoring of artificial infiltration using electrical resistivity method

  • Nakazato Hiroomi;Kuroda Seiichiro;Okuyama Takehiko;Takeuchi Mutsuo;Park Mikyung;Kim Hee Joon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.362-369
    • /
    • 2003
  • A infiltration experiment of river water has been conducted to evaluate the applicability of electrical resistivity monitoring methods in an area containing gravelly deposits in Nagaoka, Japan. Apparent resistivity data, which are inverted to obtain the resistivity distribution, are measured with a newly developed system. This system can collect 490 data in an hour and be controlled with PC to store the data. Subsurface resistivity sections, which are obtained from two-dimensional nonlinear inversion of time-lapse apparent resistivity data, enable us to estimate the direction of the flow and the rate of infiltration. The infiltration rate is estimated to be $4.4{\times}10^4m/s$ in the early stage of the experiment when the infiltration process is dominant.

  • PDF