• Title/Summary/Keyword: Water Resistivity

Search Result 383, Processing Time 0.023 seconds

Thermoelectric characteristics depend on compositions of $Bi_2Te_3$ in mixed alloy with PbTe

  • Jung, Kyoo-Ho;Yim, Ju-Hyuk;Kim, Jin-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03a
    • /
    • pp.11-11
    • /
    • 2010
  • In order to design for nano structured materials with enhanced thermoelectric properties, the alloys in the pseudo-binary $Bi_2Te_3$-PbTe system were investigated for their micro structure and thermal properties. For this synthesis the liquid alloys were cooled by water quenching method. The micro structure images were taken by using electron probe micro analyzer (EPMA). Dendritic and lamellar structures were clearly observed with the variation in the composition ratio between $Bi_2Te_3$ and PbTe. It was confirmed that a metastable compounds is $PbBi_2Te_4$ in the The $Bi_2Te_3$-PbTe system. The change in the composition increasing $Bi_2Te_3$ ratio causes to change structure from dendritic to lamellar. Seebeck coefficient of alloys 5 which the mixture rate of $Bi_2Te_3$ is 83% was measured as the highest value. In contrast, the others decreased by increasing $Bi_2Te_3$. n-type characteristics was observed at all condition except alloy 6 which $Bi_2Te_3$ ration is 91%. The power factors of all samples were calculated with Seebeck coefficient and resistivity. Also the thermal conductivity was measured by using laser flash analyzer (LFA). In this work, the microstructures and thermal properties have been measured as a function of ratio of $Bi_2Te_3$ in the $Bi_2Te_3$-PbTe system.

  • PDF

Effect of Milled Glass Fibers on Corrosion Resistance of PSC Grout Mortar (초단유리섬유가 PSC 그라우트의 부식저항성능에 미치는 영향)

  • Moon, Do-Young;Kim, Sang-Woon;Kim, Dong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.37-45
    • /
    • 2015
  • In this experimental study, effect of milled glass fibers was investigated on corrosion resistance of PSC grout mortar. In order to check whether the mortar mixture with milled glass fibers satisfy the required properties as a PSC grout, time of flow, bleeding and compressive strength measured. The corrosion resistance were investigated through chloride ion migration test, mortar absorption test and surface resistivity measurement. It is confirmed that all proportions with milled glass fibers have better corrosion resistance than that with only OPC binder. Time of flow was reduced but the bleeding was increased to unacceptable level by using milled glass fibers. Consequently, the mix proportion with milled glass fibers for a PSC grout should be modified to have lower water/binder ratio.

Effects of Wood Flour Size on the Physical Properties of Polypropylene/Wood Flour Composites (목분의 크기가 폴리프로필렌/목분 복합재료의 물성에 미치는 영향)

  • Seo, Yong Won;Kim, Dae Su
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.327-332
    • /
    • 2014
  • Polymer/wood flour composites are recently attracting a lot of interest because they are economic and ecofriendly. In this study, the effects of wood flour size on the thermal and mechanical properties of a polypropylene/wood flour composite were investigated. Mechanical properties of the composite samples prepared by melt-mixing and compression molding were tested by UTM and an izod impact tester, and thermal properties of them were measured by TGA, DMA, DSC and TMA. The best coupling agent was selected by testing three kinds of maleic anhydride modified polypropylene coupling agents, and under the same condition, the effects of wood flour size on the physical properties of the composite were investigated. According to the test results for four different wood flour sizes of 600, 250, 180 and $150{\mu}m$, flexural strength, flexural modulus, crystallinity and water-resistivity of the composite increased with decreasing wood flour size.

Impact of quorum quenching bacteria on biofouling retardation in submerged membrane bioreactor (SMBR)

  • Pervez, Saimar;Khan, Sher Jamal;Waheed, Hira;Hashmi, Imran;Lee, Chung-Hak
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.279-284
    • /
    • 2018
  • Membrane biofouling is a critical operational problem that hinders the rapid commercialization of MBRs. Quorum quenching (QQ) has been investigated widely to control membrane biofouling and is accepted as a promising anti-fouling strategy. Various QQ strategies based on bacterial and enzymatic agents have been identified and applied successfully. Whereas, this study aimed to compare indigenously isolated QQ strain i.e., Enterobacter cloaca with well reported Rhodococcus sp. BH4. Both bacterial species were immobilized in polymeric beads and introduced to two different MBRs keeping the overall beads to volume ratio as 1%. Efficiencies of these strains were monitored in terms of prolonging the membrane filtration cycle of MBR, release of extra-cellular polymeric substances, membrane resistivity measurements and mineralization of signal molecules and permeate quality. Indigenous strain (Enterobacter cloaca) was added to $QQ-MBR_E$ while Rhodococcus sp. BH4 was introduced to $QQ-MBR_R$. QQ bacterial embedded beads showed enhanced filtration cycles up to 1.4 and 2.3 times for $QQ-MBR_E$ and $QQ-MBR_R$ respectively as compared to control MBR (C-MBR). Soluble EPS concentration of 52 mg/L was observed in C-MBR while significantly lower EPS concentration of 20 and 10 mg/L was witnessed in $QQ-MBR_E$ and $QQ-MBR_R$, respectively. Therefore, substantial reduction in biofouling showed the effectiveness of indigenous strain.

A Pole-pole Electrical Survey for Groundwater (2극법 전기비저항 탐사에 의한 지하수탐사)

  • Cho Dong-heng;Jee Sang-keun
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.88-93
    • /
    • 2000
  • The present study may be summarized as follows. By means of a pole-pole electrical survey, major geological features, i.e, fresh rocks, fractured & weak & saturated rocks, fresh water bearing aquifer, were successfully delineated in the surveyed area of a granite region in Korea. The subsequent Schlumberger sounding and drilling confirmed the existence of the acquifer at 60 m depth as expected. But one more minor acquifer which does not show up in the resistivity depth section was met at 100 m depth. A simple forward modelling leads the authors to believe that any other electrode configuration, e.g., Wenner, Schlumberger, dipole-dipole, pole-dipole, would not detect the deeper aquifer. Under these circumstances, further studies remain to be done in connection with the spatial resolution in the vertical direction.

  • PDF

Ionization Behaviors in Various Soils Subjected to Impulse Currents (임펄스전류에 의한 토양의 종류별 이온화 특성)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Geon-Hun;Baek, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.87-94
    • /
    • 2008
  • This parer presents the soil ionization phenomena and parameters associated to characterize the transient performances of grounding system under lightning impulse Currents. Ionization properties in occurring some soil media were experimentally investigated. The cylindrical test cell was employed in order to facilitate the analysis of soil breakdown field intensity and ionized radius. The soil breakdown field intensity, dependence of impedance on the amplitude of impulse current, V-I curves and transient impedances were discussed based on the voltage and current oscillograms. It was found that the ionization process and dynamic behaviors were strongly dependent on the types of soil and two current peaks were not observed in highly water-saturated soils. The results presented in this paper will provide useful information on the improvement of transient performance of a grounding system subjected to lightning impulse Current considering the soil ionization.

Evaluation of Dynamic Ground Properties of Pohang Area Based on In-situ and Laboratory Test (현장실험 및 동적실내실험을 이용한 포항지역 동적 지반특성 평가)

  • Kim, Jongkwan;Kwak, Tae-Young;Han, Jin-Tae;Hwang, Byong-Youn;Kim, Ki-Seog
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.5-20
    • /
    • 2020
  • In 2017, after the Pohang earthquake, liquefaction phenomena were firstly observed after the observation of domestic earthquake by epicenter. In this study, various in-situ tests and laboratory tests were performed to determine the dynamic properties in (1) Songlim Park, (2) Heunghae-eup, Mangcheon-ri and (3) Heungan-ri, Pohang. As a site investigation, the standard penetration test (SPT), cone penetration test (CPT), multichannel analysis of surface wave (MASW), density logging, downhole test, and electrical resistivity survey were performed. In addition, cyclic triaxial test against sampled sand from site was also conducted. Based on the result, high ground water level and loose sand layer in shallow depth were observed for all sites. In addition, liquefaction resistance ratio of soil sampled from Songlim park was lower than those of Jumunjin sand, Toyoura sand, and Ottawa sand.

Development of a Nondestructive Seismic Technique for Flexural Rigidity of Concrete Track as Slab Displacement Index (콘크리트 슬래브궤도의 휨강성 평가를 위한 비파괴 탄성파 기법의 개발)

  • Cho, Mi-Ra;Joh, Sung-Ho;Lee, Il-Wha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.905-913
    • /
    • 2008
  • Recently, concrete tracks are introduced into high-speed railroads as an alternative to ballast tracks. Concrete tracks are superior to ballast tracks in the aspect of durability, maintenance and safety. However, deteriorated stiffness of railroad bed and settlement of soft ground induced by trapped or seepage water lead to problems in safety of train operation. In this research, flexural rigidity of concrete tracks was employed as an index of track displacement and a new seismic technique called FRACTAL (Flexural-Rigidity Assessment of Concrete Tracks by Antisymmetric Lamb Waves) method was proposed to delineate flexural rigidity of concrete tracks in a 2-D image. In this paper, to establish theoretical background, parametric research was performed using numerical simulations of stress-wave tests at concrete tracks. Feasibility of the FRACTAL technique was proved at a real concrete track for Korean high-speed trains. Validity of the FRACTAL technique was also verified by comparing the results of impulse-response tests performed at the same measurement array and the results of DC resistivity survey performed at a shoulder nearby the track.

A Feasibility Study of AMT Application to Tidal Flat Sedimentary Layer (갯벌 지역의 하부퇴적층에 대한 AMT 탐사의 적용 가능성 평가)

  • Kwon, Byung-Doo;Lee, Choon-Ki;Park, Gye-Soon;Choi, Su-Young;Yoo, Hee-Young;Choi, Jong-Keun;Eom, Joo-Young
    • Journal of the Korean earth science society
    • /
    • v.28 no.1
    • /
    • pp.64-74
    • /
    • 2007
  • The marine seismic prospecting using a research vessel in the shallow sea near the coastal area has certain limits according to the water depth and survey environment. Also, for the electrical resistivity survey at seashore area, one may need a specially designed high-voltage source to penetrate the very conductive surface layer. Therefore, we have conducted a feasibility study on the application of magnetotelluric method (MT), a passive geophysical method, on investigating of shallow marine environment geology. Our study involves both theoretical modeling and field survey at the tidal flat area which represent the very shallow marine environment. We have applied the audio-frequency magnetotelluric (AMT) method to the intertidal deposits of Gunhung Bay, west coast of Korea, and analysed the field data both qualitatively and quantitatively to investigate the morphology and sedimentary stratigraphy of the tidal flat. The inversion of AMT data well reveals the upper sedimentary layer of Holocene intertidal sediments having a range of 13-20 m thickness and the erosional patterns at the unconformable contact boundary. However, the AMT inversion results tend to overestimate the depth of basement (30-50 m) when compared with the seismic section (27-33 m). Since MT responses are not significantly sensitive to the resistivity of middle layer or the depth of basement, the AMT inversion result for basement may have to be adjusted using the comparison with other geophysical information like seismic section or logging data if possible. But, the AMT method can be an effective alternative choice for investigating the seashore area to get important basic informations such as the depositional environment of the tidal flat, sea-water intrusion and the basement structure near the sea shore.

The Effect of Residual H2Pressure on Gallium-doped ZnO Films Deposited by Magnetron Sputtering (마그네트론 스퍼터링에 의해 제작한 Gallium-doped ZnO 박막에 있어서 잔류 H2O 분압의 영향)

  • Song, Pung-Keun;Kwon, Young-Jun;Cha, Jae-Min;Lee, Byung-Chul;Ryu, Bong-Ki;Kim, Kwang-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.10
    • /
    • pp.928-934
    • /
    • 2002
  • Gallium doped Zinc Oxide(GZO) films were deposited by dc magnetron sputtering using a GZO ceramic target at various conditions such as substrate temperature (RT, 400), residual water pressure ($P_{H_2O}$; 1.61${\times}10^{-4}∼2.2{\times}10^{-3}$ Pa), introduction of $H_2$ gas (8.5%) and different magnetic field strengths(250, 1000G). GZO films deposited without substrate heating showed clear degradation in film crystallinity and electrical properties with increasing $P_{H_2O}$. The resistivity increased from 3.0${\times}10^{-3}$ to 3.1${\times}10^{-2}{\Omega}㎝$ and the grain size of the films decreased from 24 to 3 nm when PH2O was increased from 1.61${\times}10^{-4}$ to 2.2${\times}10^{-3}$ Pa. However, degradation in electrical properties with increasing $P_{H_2O}$ was not observed for the films deposited with introduction of 8.5% $H_2$. When magnetic field strength of the cathode increased from 250G to 1000G, crystallinity and electrical properties of GZO films improved remarkably about all the $P_{H_2O}$. This result could be attributed to the decrease in film damage caused by the decrease in plasma impedance.