• Title/Summary/Keyword: Water Recycling Facility

Search Result 30, Processing Time 0.023 seconds

Construction Method of Zero Discharge System for Environmental Energy Complex in Landfill (매립지내 환경에너지단지의 무방류 시스템 구축방안)

  • Chun, Seung-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.581-590
    • /
    • 2013
  • A research was performed for zero discharge system of waste water which is produced from energy recovery process of waste and biomass. Leachate and all kinds of waste water should be separated and integrated into three categories in addition to converting existing leachate treatment facility into waste water treatment facility as well as introducing a management system of reverse osmosis membrane facility and bioreactor landfill. Following these conditions to better water treatment process, it was likely to produce over 3,000 tons of low-grade recycling water and 2,000 tons of high-grade recycling water per day when zero discharge system of waste water is applied starting from 2016. Economical efficiency was also surveyed in total treatment fee. Present system costs 18,129 million won per year, and suggested zero discharge system would cost 15,789 million won per year.

Recycling of a discarded septic tank as a rainwater management system and it's economic feasibility analysis (폐정화조를 재활용한 다목적 빗물관리시스템 구상 및 경제성 분석)

  • Kim, Mikyeong;Kwak, Donggeun;Han, Mooyoung;Yang, Jichung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.647-654
    • /
    • 2009
  • Since the end of the 1990s, sewer pipe improvement works have been going on: most septic tanks have been thrown away and discarded. These discarded septic tanks amounts up to 370,000 based on the project plan 2005-2008: it is a serious squander of nation's resources, a contaminating means that buries toxins under soil, and a cause of a expensive waste. Research on recycling of discarded septic tank as a new resource is in urgent need. This research suggests plans to recycle discarded septic tank as a rainwater management facility, solutions to water cycle recovery in the limelight, and economic analysis of the plan. In the case of a recycling discarded septic tank as a rainwater management facility will socially benefit to support economical adequacy, discard cost saving of septic tank and water supply and sewage cost reduction will come out. Consequently a rainwater management facility converted from a discarded septic tank leads to decentralization of the rainwater management system, which anticipates a positive effect on recovery of urban water cycle.

Study on the Improvement of Water Regeneration Center by Using Non-water-soluble Sanitary Products: Focusing on the case of Seoul City (비수용성 위생용품 사용에 따른 물재생센터 개선방안: 서울시를 중심으로)

  • Choong-Gon Kim;Yoon-Hwan Bae;Hyun-Gon Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.2
    • /
    • pp.39-44
    • /
    • 2023
  • This study was conducted to analyze problems related to non-water-soluble sanitary products during the treatment of water regeneration centers in E.T.F. and S.T.F. at a time when the demand and supply of non-water-soluble sanitary products are increasing. As a result, the improvement plan of the W.R.C. should focus on pretreatment facilities. When replacing facilities in the future, various dust removers suitable for the facility's reality will be installed in the pretreatment of S.T.F., and it is proposed to link a bar-racks screen with a comprehensive treatment device or install a comprehensive treatment device for impurities alone in the pretreatment of E.T.F.. In addition, a microscreen screen must be installed on the front end of the excretory treatment unit. to separate non-water-soluble materials, and it is necessary to secure a maintenance space for the excretory treatment unit.

Development of a Micro-Bubble System for Ozone Off-Gas Recycling in the Ozone Treatment Process (오존처리공정의 배오존 재활용 마이크로버블시스템 개발)

  • Young-Man, Cho;Jae-Ouk, Jung;Kwang-Heon, Lee;Yong-Jun, Jung
    • Journal of Environmental Science International
    • /
    • v.31 no.12
    • /
    • pp.1061-1068
    • /
    • 2022
  • The purpose of this study was to develop a recycling system for ozone off-gas. Although the ozone transmission rate of the injector method differs slightly depending on the ozone injection rate, it reaches approximately 99%, which is very high. During the increase in water inflow to the ozone recycling system from 2 L/min to 10 L/min, the average ozone recycling rate was 99.4% at a 1 ppm ozone injection rate, 98.6% at a 2 ppm ozone injection rate, 98.1% at a 3 ppm ozone injection rate. Ozone treatment facility operating costs can be divided into the costs of pure oxygen production, ozone production, and maintenance. The annual operating costs of ozone treatment facilities in Korea are estimated to be approximately 38.9 billion won. The annual savings are estimated to be approximately 5.8 billion won when the ozone transfer rate of the diffuser method, which is mostly employed in domestic water treatment plants, is 85% and 15% of the ozone is recycled.

Assessment of GHG Reduction Strategy - A Case of Environmental Facilities of Incheon City - (온실가스 감축 전략의 성과평가 - 지자체 환경기초시설 사례 -)

  • Jang, Jong-Ok;Lee, Sung Wook;Kim, Jong Dae
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.509-519
    • /
    • 2017
  • The study focuses on 32 environmental facilities in Incheon Metropolitan City, South Korea, categorizes them by sector: sewage treatment, wastewater treatment, incineration, landfill, water purification, and water supply. Their GHG reduction results are analyzed through quantitative and qualitative measures for 2012 to 2015. The study surveys and examines GHG reductions of the environmental facilities for two categories - facility operation and management. The findings are as follows: First, the GHG reduction rate, an emission-to-allocation ratio, from 2012 to 2015 is 89.67%. Second, GHG reductions coming from qualitative measures of facility management are even greater than those from quantitative measures of facility operation. Third, GHG reductions through facility operation are mostly attributable to overhauls, less use of facilities, resources recycling, process improvement rather than the betterment of fuels, facilities and energy efficiency. Fourth, higher reduction can be achieved by effective facility management, qualitative measures.

Characteristics of Compost Produced from the Composting Facility at Nanjido (난지도 퇴비화시범시설에서 생산되는 퇴비의 품질특성)

  • Namkoong, Wan;Kim, Joung-Dae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.5 no.2
    • /
    • pp.57-64
    • /
    • 1997
  • This study was performed to investigate the characteristics of compost produced from the composting facility at Nanjido. The capacity of the facility is 10 ton/day. Feed material was food waste generated in Seoul. Moisture content of the compost product was 31% and conductivity was 2.6 mmhos/cm. The compost product met Korean quality standards and EC quality standards for VS and C/N ratio. In case of TOC and TKN, they were met with Japan quality standards. The water soluble-C/N ratio finally reached about 5 based on dry compost. The color of compost product was dark brown. The product had earthy smell. Heavy metal contents of the compost were below Korean quality standards by wet basis.

  • PDF

Waterproof Characteristic for Environmental Water Flows in Small Streams (소규모 하천 친환경 물흐름을 위한 차수특성)

  • Park, Min-Cheol;Kim, Seong-Goo;Lee, Song
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.192-199
    • /
    • 2010
  • This research produced internal model tester ($2.0m{\times}2.0m{\times}1.0m$) to evaluate the field application of Paju Unjeong District water recycling system for small streams eco-friendly river bed disparity method for the first time in Korea and conducted comparative analysis of the Paju Unjeong District water recycling system field test results and infiltration rate result of internal tests by each rainfall intensity following surface material. Infiltration rate result of internal tests concrete pavement by rainfall intensity following surface material, asphalt pavement, bentonite mate, stabilized soil construction and mixed soil construction manifested low infiltration rate. On the contrary, compaction soil, grassland and water permeable packaging materials resulted in significant amount of infiltration rate. As for the field permeability test results, they were manifested similar tendency as indoor permeability test results and they satisfied the standard for standard of water permeability of domestic disparity facility (less than $1.0{\times}10-7cm$/sec). As compaction rate increased, unconfined compression strength increased as well while coefficient of water permeability decreased.

  • PDF

A Study on Pre-treatment Facility for Foodwaste and Sewage Sludge Mixture (음식폐기물과 하수슬러지 병합처리를 위한 전처리시설에 관한 연구)

  • Kim, Jong-Oh;Lee, Chang-Ho;Kim, Ji-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.1
    • /
    • pp.84-89
    • /
    • 2003
  • The purpose of this study was to evaluate and improve the pre-treatment facility for foodwaste and sewage sludge mixture treatment. The process of foodwaste pre-treatment consists of storage, classification with crushing, and thickening. The effluent of sewage treatment facility was used as the diluting and washing water. The panicle size of foodwaste after pre-treatment was almost under 2mm, the mixture of foodwastes and sewage sludge showed an advantage to the anaerobic digestion. The amount of gas production increased from 0.8ton/day ($CH_4$ : 0.5ton/day) to 3.5ton/day ($CH_4$ : 2.3ton/day) after the anaerobic digestion of the foodwastes and sewage sludge mixture. The amount of sludge cake increased from 11.2ton/day to 21.2ton/day. Therefore, the proper operation of the foodwaste pre-treatment facility was contributed to the efficient anaerobic digestion of foodwaste and sewage sludge mixture treatment.

  • PDF

Study on the Improvement Process for the Food Waste Resource Facility (II) - Focus on Deodorization Facility of DDM Environment Resource Center - (음식물류 폐기물 자원화시설의 공정개선에 관한 연구(II) - DDM환경자원센터의 탈취시설 사례를 중심으로 -)

  • Kim, Choong-Gon;Bae, Yoonhwan;SHIN, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • This study refers to the deodorization of DDM Environmental Resource Center, which is operating abnormally in the food waste public-resource facilities that are operating nationwide, in accordance with the initial operating conditions. Issues concerning the abnormal deodorization facilities of DDM Environment Resource Center were the deodorization of composting facilities, indoor air quality problems, and overall deodorization of facilities, especially the phenomenon of stopping while operating the RTO and the phenomenon of poor spray in the wet scrubber etc. As an alternative and improvement method for converting such abnormal operation facilities into normal operation facilities, It is proposed to remove the front filter of the upper part of the fermentation tank, and to install scrubbers, air and water separator, and roll filters for dust removal etc.

Total assessment for phosphorus input load of public wastewater and livestock manure treatment facilities in Korea (우리나라 공공하수처리시설 및 가축분뇨공공 처리시설의 인(P) 유입부하량에 대한 총량평가)

  • Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.4
    • /
    • pp.325-335
    • /
    • 2018
  • The annual total phosphorus load caused by public wastewater, nightsoil and livestock manure treatment facilities in Korea has been examined macroscopically. Annual domestic average phosphorus (P) inflows through the income of phosphate rock for the last five years (2012 - 2016) were analyzed as 76,598 tons/year. As of the year 2015, the total loadings of phosphorus attributed to public wastewater treatment facilities, nightsoil treatment facilities and livestock wastewater were estimated as 30,269 tons/year, 1,909 tons/year and 18,138 tons/year, respectively. Considering the amount of phosphorus imports, the annual phosphorus load from wastewater, livestock wastewater and excretions is equivalent to 39.5%, 23.7%, 2.5% and totally 65.7%(39.5% + 23.7% + 2.5%). Therefore, the introduction of phosphorus recovery and recycling processes for the public wastewater and livestock manure treatment facilities has been found to be effective because it could reduce the import amount of phosphate rock by up to 60% or more.