• Title/Summary/Keyword: Water Quantity

Search Result 1,454, Processing Time 0.025 seconds

A Study on the status of unit water content control of the Ready-Mixed Concrete plants in the country (국내 레미콘 플랜트의 단위수량관리 현황 검토에 관한 연구)

  • Jung, Yang-Hee;Kim, Yong-Ro;Choi, Il-Ho;Lee, Do-Bum;Hong, Kyung-Seon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.606-609
    • /
    • 2006
  • In this study, it was selected that in order to make an investigation into the status of the unit water content control of the ready-mixed concrete plants in the country, Capacitance Measurement Method out of various methods which are able to gauge the amount of unit water content in fresh concrete. Then, it were estimated that the quantity of unit water in fresh concrete and the technical standard of every mixture design of the six ready-mixed concrete plants chosen at random in the country. Finally, based on this study, it was proposed as fundamental data to utilize measurement techniques of the quantity of unit water for the quality control of the ready-mixed concrete in construction field.

  • PDF

A Study on Daily Water Demand Prediction Model (급수량(給水量) 단기(短期) 수요예측(需要豫測)에 대한 연구(硏究))

  • Koo, Jayoug;Koizwui, Akirau;Inakazu, Toyono
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.109-118
    • /
    • 1997
  • In this study, we examined the structural analysis of water demand fluctuation for water distribution control of water supply network. In order to analyze for the length of stationary time series, we calculate autocorrelation coefficient of each case equally divided data size. As a result, it was found that, with the data size of around three months, any case could be used as stationary time series. we analyze cross-correlation coefficient between the daily water consumption's data and primary influence factors. As a result, we have decided to use weather conditions and maximum temperature as natural primary factors and holidays as a social factor. Applying the multiple ARIMA model, we obtains an effective model to describe the daily water demand prediction. From the forecasting result, even though we forecast water distribution quantity of the following year, estimated values well express the flctuations of measurements. Thus, the suitability of the model for practical use can be confirmed. When this model is used for practical water distribution control, water distribution quantity for the following day should be found by inputting maximum temperature and weather conditions obtained from weather forecast, and water purification plants and service reservoirs should be operated based on this information while operation of pumps and valves should be set up. Consequently, we will be able to devise a rational water management system.

  • PDF

Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path (사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안)

  • Kim, Jung-Soo;Song Ju-Il;Rim Chang-Soo;Yoon, Sei-Eui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.

Numerical Simulation of water quality by ${\Delta}COD$ method for Inner Productivity Estimation of Yeong-Il Bay (간이변환 수질예측모델에 의한 영일만 내부생산성 평가)

  • Yoon, Han-Sam;Ryu, Cheong-Ro;Lee, In-Cheol;Kim, Heon-Tae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.99-104
    • /
    • 2003
  • This study investigated the yearly variation of pollutant loads outflowing from six watershed of Yeong-il Bay and compared the relationship of pollutant load and water quality, and estimated the Inner productivity of Yeong-Il Bay by using ${\Delta}COD$ method which analysis nonlinear process of water quality. As the estimated results for the pollutant loads of Yeong-Il Bay, total COD load outflowing from Hyeong-san river in flood season(summer) of 2001 year was 2275.0 kg/hr and in dry(low water) season(winter) 852.8 kg/hr, respectively. Load quantity in flood season was about 2.67 times than that in dry season. And as the calculated results of the net-flux of water for seven divisions, it showed that the net-flux of water increased for the divisions of the north coast and inner sea of Yeong-Il Bay but decreased for the south coast. On the contrary, for the cases which water quantity increase from land, the net-flux of water in estuary front of Hyeong-san river decreased but outflowing quantity of that though division of the south coast of Homi-got increased. Finally, this study compared the Inner productions for flood and dry season of Yeong-il Bay by using ${\Delta}COD$ method.

  • PDF

An Experimental Study on the Improvement of Durability of Dam Concrete (댐콘크리트의 내구성 향상에 관한 실험적 연구)

  • 윤영수;원종필;송영철;우상균;송유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.415-420
    • /
    • 1999
  • Dam concrete should have sufficient durability in wet and dry repetition and abrasion due to water lever variance and also in freezing and thawing resistance as well as water penetration capacity. This study presents various experimental performance to enhance the durability of face slab concrete in concrete face rockfill dam by varying the fly ash substitution of 0%, 10%, 15% and 20% in cement quantity. The effect on durability corresponding to the increasing amount of fly-ash was evaluated and the optimum quantity of fly-ash subtitution was finally recommended. The results show that 15% fly-ash substituion was found out to be an optimum quantity and demonstrated an excellent performances in durability.

  • PDF

Properties of Boards Prepared From Woody of Broussonetia Kazinoki Sieb. (닥나무 목질부로 제조된 보드의 성질(I))

  • Oh, Seung Won;Park, Seong Cheol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.216-221
    • /
    • 2009
  • This study was investigated the properties of boards prepared from woody of Broussonetia Kazinoki differed in density of board and mixed quantity of powdered phenolic resin. Water absorption decreased as the density of boards and resin content increased, but bending strength and brinell hardness increased as the density of board and the quantity of resin added increased. Thickness swelling increased as the density of boards went up, and that, in contrary, decreased as the quantity of resin added to the boards.

Development and Application of Rainwater Collection Model by the Ground (우수의 지표 포집 모델의 개발 및 적용)

  • Lee, Dong-Kon;Lee, Kil-Soo;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.173-180
    • /
    • 2005
  • In this study, quantity and quality of collected rainwater by the ground collection system were investigated and the Rainwater Collection Prediction Model was developed to predict the amount of collected rainwater. The quantity of collected rainwater in the collection system was 9516 L(38.2%) and the quantity of infiltrated rainwater in the collection system was 9946 L(40.2%) through $25m^2$ area for the study period, respectively. Average turbidity of collected rainwater in collection system was 2.2 NTU, and average turbidity of infiltrated rainwater in collection system was 2.3 NTU for study period, respectively. The predicted amount by the model and the actual collected amount were 9842.4 L and 9516 L, which were very close showing that prediction was excellent. The optimal rainwater storage tank volume was simulated with a certain consumption condition for various cities with different rainfall patterns.

Study on decentralized options of the in-stream flow for restoring the Gyobang cheon: application of the Urban Volume and Quality (UVQ) model to examine feasibilities in water quantity and quality (교방천 복원을 위한 분산형 유지유량 확보 방안 연구 (I): 수량.수질 타당성 검토를 위한 도시 물순환 모형 적용)

  • Shin, Sang-Min;Choi, Go-Eun;Lee, Sang-Eun;Park, Hee-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.699-706
    • /
    • 2011
  • This study has a purpose of examining technical feasibility of supplying the in-stream flow for the Gyobang cheon by using treated water from small wastewater treatment facilities as a decentralized option. To do this, the water and contaminant flow in study areas of the Gyobang cheon are defined from the context of the integrated urban water cycle, and analyzed by using the Urban Volume and Quality (UVQ) model. First, the UVQ model was built for the study areas of the Gyobang cheon and calibrated with observation data. Second, the decentralized options of the in-stream flow was explored with consideration of availability of water sources. The UVQ simulation then led to selecting the best option which would meet the criteria of water quantity and quality. It was finally concluded that using water sources out of study areas 1 and 2, adjoining the upper part of the Gyobang cheon, in the decentralized manner can be a feasible option for in-stream flow. It also seems that the UVQ model is useful to understand the water cycle in study areas of the Gyobang cheon.

A Study on Design Area of Fire Sprinkler System (스프링클러설비의 설계면적에 대한 연구)

  • Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.93-98
    • /
    • 2010
  • Even though the sprinkler system is a essential fire suppression system, the design engineers do not fully understand the concept of design area which sprinklers operate. They frequently made a mistake to form design area and calculate it. The shape of design area is a square or a rectangle which branch side line is a little longer than the cross main side. NFPA demands to lengthen the branch side to 1.2 times than the cross main side and FM demands 1.4 times. The longer the branch side at the same design area is, the bigger the water quantity and pressure is. At the results of hydraulic calculation of design areas, when the branch side is longer 1.2 times, the water quantity became 4.6% bigger than exact square and the pressure came to 4.67% bigger. When it is longer 1.4 times, the water quantity and the pressure are bigger 7.52%, 14.51%. Therefore, the sprinkler design engineers should follow the general rule of design area, exact square or rectangle which length along the branch line is a little longer than length along the cross main, to design more stable system.

A Study on the Cooling Heating Performance Experiment by Refrigerant Auto Control of Geothermal Heat Pump (지열히트펌프 냉매자동조절에 따른 냉·난방 성능실험에 관한 연구)

  • Koo, Nam-Yeol;Seo, Seung-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • This study presents analysis of the experimental data meeting conditions of several applications in real time. The results of this experimental study are as follows: Respectively in cooling and heating performance, a refrigerant charge tank can take automatic control of variation of the refrigerant quantity by controling pressure and temperature of system and outlet water temperature. The COP shows 3.5 in cooling operation and 3.2 in heating operation. The refrigerant quantity increases 0.69 kJ/h. When the outdoor temperature decreases $1^{\circ}C$, Therefore if the temperature become lower from $25^{\circ}C$ to $-16^{\circ}C$, the refrigerant quantity increases about 9.5%. Compared to the normal state experiment results, the COP in automatic control of the refrigerant quantity rises roughly 10%.