• Title/Summary/Keyword: Water Quality Standards

Search Result 475, Processing Time 0.131 seconds

Forecasting of changes in the water quality in Sapgyo-Lake in accordance with implementation of Total Water Pollutant Load Management System (수질오염총량관리제 시행에 따른 삽교호의 수질변화 예측)

  • Kim, Hongsu;Cho, Byunguk;Park, Sanghyun;Lee, Mukyu;Kim, Changgi;Choi, Jeongho
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.3
    • /
    • pp.209-223
    • /
    • 2019
  • Broadly speaking, in order to analyze the water quality improvement effects of the implementation of the Total Water Pollutant Management System in the Sapgy-Lake waterways, a reference was made to the [Plans for implementation of the Total Maximum Daily Load(TMDL)] in 3 cities (Cheonan, Asan, Dangjin). The results of the investigation into the plans to reduce the pollutant load show in that region show that there are plans to reduce pollution for a total of 16 reduction facilities. As for the result of the computation of the reduction in the load, these measurements were computed at the Gokgyo-stream basin and Namwon-stream basin, with BOD and T-P at the Gokgyo-stream basin reduced by 13.9 % and 13.3 %, respectively, while BOD and T-P at the Namwon-stream were reduced by 3.7 % and 3.3 %, respectively. In this way, thus using the results of the water quality forecast of Sapgyo-Lake in measures for the improvement of water quality (in accordance with the implementation of the TMDL), and using the QUAL-MEV model and EFDC model, it is noted that BOD will be improved by 26.4 % from 6.1 mg/L to 4.5 mg/L 0.0 %, T-P by 36.7 % from 0.168 mg/L to 0.107 mg/L and TOC by 26.4 % from 7.7 mg/L to 5.6 mg/L. However, it is forecasted that the targeted standards for the medium influence area will not be achieved. Evidently, Gokgyo-stream and Namwon-stream have been implementing the Total Water Pollutant Management System for the BOD items since January 1, 2019, but the Sapgyo-stream and Muhan-stream were excluded from being designated as subject regions. As such, it is noted now that it is necessary to implement the TMDL for the entire Sapgyo-Lake water systems including Sapgyo-stream and Muhan-stream in order to improve the water quality of Sapgyo-Lake, and likewise the T-P should be designated as the substance subjected to management in addition to BOD.

Field Applications on Groundwater Management Scheme of Subwatershed Unit in Hampyeong-Gun (단위유역 단위의 지하수 관리기법 현장적용성 검토 (함평군 중심으로))

  • Jung, Chan Duck;Song, In sung
    • Economic and Environmental Geology
    • /
    • v.46 no.6
    • /
    • pp.545-559
    • /
    • 2013
  • Until now, research achievements of groundwater such as groundwater to depth distribution, usage, the available amount of development, water quality have been written in the watershed units($25{\sim}250km^2$). However, complex topography and geology, and the rivers of our country does not fit. And a clear management standards have not been able to present measures in groundwater quantity, water quality management such as rainfall, groundwater, utilization, water quality, pollution, etc. Therefore, in this study, the classification criterion of subwatershed unit($2.5{\sim}25km^2$), which is suitable for topography and geology of Korea, for rainfall-rating, groundwater level-rating, groundwater pollution-rating, groundwater quality-rating presented and proved its efficiency by applying in Hampyeong-Gun area.

Chemical Ranking and Scoring Methodology for the Drinking and non-drinking Groundwater pollutants: CROWN (Chemical Ranking of Groundwater PollutaNts) (음용 및 비음용 지하수 우선관리대상 항목 선정기법: CROWN (Chemical Ranking of Groundwater PollutaNts))

  • An, Youn-Joo;Lee, Woo-Mi;Jeong, Seung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.16-25
    • /
    • 2013
  • The Korean groundwater law regulates 20 groundwater contamination parameters, including 14 specific harmful substances. Expanding the number of groundwater quality standards are needed to cope with recent groundwater quality deterioration due to the use of various chemicals. Chemical ranking and scoring system (CRS) is a scientific tool to sort priority chemicals by considering exposure and toxicity potentials. In this study, we developed a CRS for scoring and ranking of possible groundwater pollutants and screened priority substances to be later considered in the Korean standard expansion. Chemical Ranking Of groundWater pollutaNts (CROWN) incorporates important parameters consisting of exposure potential, human and water ecotoxicity, interests, and certainty. Furthermore, CROWN additionally evaluated existence of other media standards to consider impacts by contamination of other media. The 197 substances that were common to 9 countries were selected first. CROWN evaluated and ranked each chemical, and finally suggested priority substances. Suggested priority substances were classified into two groups according to the groundwater use purposes: drinking and non-drinking. The priority substances were further classified into $1^{st}$ and $2^{nd}$ group priorities. The $1^{st}$ group consists of 75 substances, including the all the Korean groundwater standard parameters. CROWN will be used in selecting groundwater pollutants for possible inclusion in the Korean standard expansion.

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

Temporal Trend Analysis of Contamination using Groundwater Quality Monitoring Network Data (지하수 수질측정망 자료를 활용한 시간적 오염도 추이변화 분석)

  • Bang, Sara;Yoo, Keunje;Park, Joonhong
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.120-128
    • /
    • 2011
  • Korea Groundwater Quality Monitoring Network is a database of annual groundwater quality survey results to prevent groundwater pollution. We estimated contamination index (CI) values for each type of land use, and analyzed temporal trends of pollutant concentration data in the Groundwater Quality Monitoring Network from 2001 to 2009. Among the pollutants considered in the database, the concentrations of nitrate and chloride were higher than their standards. In the case of nitrate, recreation parks, golf courses and general waste dumping regions showed increasing trends according to linear regression analysis, whereas industrial complexes and residential regions of urgan and recreation parks showed increasing trends in the chloride concentration data. According to multiple variable linear regression analysis, EC, pH and topography were major factors influencing CI values. These results suggest that groundwater with a high CI value and increasing trend is vulnerable for potential contamination, which requires more careful groundwater pollution control.

Models for drinking water treatment processes

  • Jusic, Suvada;Milasinovic, Zoran;Milisic, Hata;Hadzic, Emina
    • Coupled systems mechanics
    • /
    • v.8 no.6
    • /
    • pp.489-500
    • /
    • 2019
  • With drinking water standards becoming more rigorous and increasing demands for additional water quantities, while water resources are becoming more polluted, mathematical models became an important tool to improve water treatment processes performance in the water supply system. Water treatment processes models reflect the knowledge of the processes and they are useful tools for water treatment process optimization, design, operator training for decision making and fundamental research. Unfortunately, in the current practice of drinking-water production and distribution, water treatment processes modeling is not successfully applied. This article presents a review of some existing water treatment processes simulators and the experience of their application and indicating the main weak points of each process. Also, new approaches in the modeling of water treatment are presented and recommendations are given for the work in the future.

Applicability of SBR and MBR Combined Process Meets the Water Quality Standards of MEPC. 227(64) (MEPC. 227(64) 수질기준에 의한 SBR 및 MBR 복합공정 적용 가능성 평가)

  • Jung, Jin-Hee;Lee, Seung-Chul;Lee, Seul-Kee;Han, Young-Rip;Youn, Young-Nea;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1609-1616
    • /
    • 2015
  • The objective of this study was to make a SBR+MBR complex process to evaluate the possible use of the advanced water treatment system for ships (SBR+MBR complex process) in accordance with the amendments MAPOL 73/78 that went into effect. The conditions 1 and 2 did not show the quick reduction in anaerobic condition while in the precipitation and stirring stages of the SBR treatment which was determined to be ineffective denitrification, same as with the ORP. Removal of organic matters such as $BOD_5$ and $COD_{Cr}$ in the SBR treatment was observed to happen smoothly and going through the MBR treatment as well would provide a stable water quality. However, the results were not satisfactory in accordance with $BOD_5$ 25 mg/L and $COD_{Cr}$ 125 mg/L. Thus, the operating conditions improvement is deemed necessary. Likewise for the nutrients (T-N and T-P), the nitrification in bioreactor, denitrification and phosphorus absorption in aerobic tank due to phosphorus release in anaerobic tank had not been proceeded effectively. It was concluded that the improved operating conditions and structural changes would provide more effective treatments since the removal rates of T-N and T-P were less than 70% and 80%, respectively, which were standards specified by the MEPC. 227(64).

Physical and Mechanical Properties of Board Made from Carbonized Rice Husk (왕겨숯을 이용하여 제조한 보드의 물성)

  • Hwang, Jung-Woo;Oh, Seung-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.62-71
    • /
    • 2017
  • This study was investigated on the properties of board made from carbonized rice husk differed in density of board, resin addition ratio and sawdust addition ratio. Water absorption is showed the lowest value to 80.09% when the resin addition ratio of 25%, as the density increased and sawdust addition ratio decreased, the water absorption was decreased. The measured thickness swelling satisfied with the quality standards of KS F 3104, so the feasibility of building interior has been confirmed in the dimensional stability. In case of resin addition ratio of 25%, the internal bond strength was satisfied quality standards of KS F 3104 to $0.244N/mm^2$. With increasing the density, resin and sawdust addition ratio, brinell hardness increased.

A Survey on the Quality Characteristics of Dried Ginseng Products (건조인삼제품의 품질 특성 조사)

  • Gil, Bog-Im
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.1003-1006
    • /
    • 2003
  • The quality of dried ginseng products (white ginseng, red ginseng, and taeguk ginseng) was investigated according to the National Standards. All the dried ginseng products met the general quality standard established: moisture content of 14.0% or less, ash content of 5.0% or less, and water-saturated n-butanol extracts of 2.0% or more. Ginsenoside $Rb_1$, Rf, and $Rg_1$, the effective components of Korean ginseng were detected by HPLC analysis. However, uniformity of individual products within a package was not kept for almost all of the products except for red ginseng products.

Chemically Enhanced Primary Treatment at D Wastewater Treatment Plant (화학적 처리에 의한 1차 하수처리장의 처리효과 개선 -현장시험을 중심으로-)

  • Kwak, Jong W.;Kim, Seung H.;Lee, Chan W.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.99-108
    • /
    • 1997
  • This study examined the feasbility of upgrading D waste water treatment plant which treats incoming wastewater by primary sedimentation only. By adding 20-40 ppm of Hi-PAX into the outlet of the aerated grit chamber, BOD and SS removal efficiences were improved from 29% and 36% to 53 % and 73%,respectively. However, chemically enhanced primary treatment failed to meet the upcoming wastewater quality standard(BOD and SS <20 mg/l) consistently. This was suspected to result from the deteriorated plant return stream. The wastewater treatment by chemical treatment should have increased the amount of the sludge to be removed as the sludge production was increased. Chemically enhanced primary treatment is anticipated to consistently produce effluent of the 1996 standards quality by adjusting the amount of the sludge to be removed. Besides BOD and SS removal, chemically enhanced primary treatment resulted in the improved T-P removal from 30% to 64-74%. However, such benefit was not observed in T-N removal. Improved T-P removal will be expected to help control water pollution in Masan bay.

  • PDF