• Title/Summary/Keyword: Water Quality Standards

Search Result 475, Processing Time 0.021 seconds

The studies about cutting, processing and decokting methods of oriental medicinal plants II : Rehmanniae Radix Preparata (한약재의 절단, 수치, 전탕법에 관한 연구II : 숙지황)

  • Kim, In-Rak;Hwang, Keum-Hee;Joo, Hea-Jung;Ma, Jin-Yeul
    • Korean Journal of Oriental Medicine
    • /
    • v.4 no.1 s.4
    • /
    • pp.115-127
    • /
    • 1998
  • To improve the quality control of frequently used oriental medicinal plants, the storage, cutting, processing and decokting methods of Rehmannia glutinosa Libosch. var. purpurea Makino(熟地黃) were examined. The contents of 5-hydroxymethyl-2- furaldehyde(5-HMF) of Rehmannia glutinosa Libosch. var. purpurea Makino were analysed by HPLC at various conditions as the standard component. Raw materials were classified into 3 groups with their specific gravity(天 地 人黃) and determined the ding weights and the contents of water, the solid component of Ji-Hwang(地黃) was the most. Rehmannia glutinosa Libosch. var purpurea Makino was steamed and dried nine times and analysed the content of 5-HMF on every time. In the case of Ji-Hwang, the standard component of the ninth sample was produced the most. But which of the tenth samples of Chun-Hwang and Yin-Hwang(天黃 人黃) were the most. The best decokting conditions which were determined by the yield of 5-HMF were as follows : non cutting, soaking time was 0 minutes, decokting time was 75 minutes after boiling. The contents of sugar on each of samples were determined. The contents of standard component increased by steaming number and the contents of sugar decreased.

  • PDF

Study on the Improvement of Water Quality by the strengthening of T-P effluent standard for Environmental Facilities in Paldang Basin (환경기초시설의 인 기준 강화에 따른 팔당호 유입 수계의 수질개선 효과분석)

  • Jeong, Won-Gu;Han, Young-Han;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.30 no.B
    • /
    • pp.125-135
    • /
    • 2010
  • The influences on water quality of each river by effluents from environmental facilities $located^{*}$ in 14 unit watersheds of North- and South-Han River, and Gyungan-cheon were analyzed. Also, the water quality modeling for study area was carried out to analyze the improvement effect of water quality by the strengthening of T-P effluent standard of environmental facilities. For the calibration and verification of model, water quality data and effluent loading calculated for 2006 were used. Data of low water period were used for calibration, and normal water period for verification. The results of calibration and verification were well matched with the real water quality dataset of revers. Also, the validity of the results were estimated using RI (Reliability Index) method. When the T-P effluent standards for environmental facilities were strengthened, T-P concentrations were predicted to improve from $0.025mg/{\ell}$ to $0.023mg/{\ell}$ in the outlet location of North-Han River, from $0.056mg/{\ell}$ to $0.040mg/{\ell}$ for South-Han River,and from $0.233mg/{\ell}$ to $0.146mg/{\ell}$ for Gyungan-cheon. Also, the T-P concentrations of tributaries including Jojong-cheon, Dal-cheong, Sumgang, Chungmi-cheon, Bokha-cheon, Heuk-cheon, and Wonju-cheon were predicted to improve from $0.063mg/{\ell}$ to $0.010mg/{\ell}$, from $0.091mg/{\ell}$ to $0.053mg/{\ell}$, from $0.199mg/{\ell}$ to $0.100mg/{\ell}$, from $0.168mg/{\ell}$ to $0.148mg/{\ell}$, from $0.186mg/{\ell}$ to $0.105mg/{\ell}$, from $0.019mg/{\ell}$ to $0.013mg/{\ell}$, and from $0.822mg/{\ell}$ to $0.236mg/{\ell}$, respectively.

  • PDF

Pond System for Further Polishing of Constructed Wetland Effluent during Winter Season (연못을 이용한 동절기 인공습지 오수처리수의 추가 처리)

  • Yoon, Chun-Gyeong;Jeon, Ji-Hong;Kim, Min-Hee;Ham, Jong-Hwa
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.44 no.4
    • /
    • pp.139-148
    • /
    • 2002
  • Pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent from December 2000 to June 2001. The wetland system used for the experiment was highly effective to treat the sewage during the growing season, but it was less effective and its effluent was still high to discharge to the receiving water body. Therefore, the wetland effluent may need further treatment to prevent water quality degradation. Pond system could be used to hold and further polish the wetland effluent during the winter season and ots feasibility was evaluated in this study. Additional water quality improvement was apparent in the pond system during winter season, and the pond effluent could be good enough to meet the effluent water quality standards if it is properly managed. Timing of the pond effluent discharge appears to be critical for pond system management because it is a closed system and whole water quality constituents are affected by physical, chemical, and biological pond environments. Once algae started to grow in mid-April, constituents in the pond water column interact each other actively and its control becomes more complicated. Therefore, upper layer of the pond water column which is clearer than the lower layer my need be discharged in March right after ice cover melted. In the experiment, water quality of the upper water column was markedly clear in March than ant other times probably because of freezing-thawing effect. The remaining lower water column could be further treated by natural purification as temperature goes up or diluted with better quality of wetland effluent for appropriate water uses. This study demonstrated the feasibility of pond system for subsequent management of wetland effluent during the winter season, however, more study is needed for field application.

The Characteristics of Drinking Groundwater Quality in Daejeon reclamation (대전광역시 음용지하수 수질의 특성)

  • Han, Woon Woo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.3
    • /
    • pp.37-45
    • /
    • 2001
  • The characteristics of drinking groundwater quality was analyzed by investigating observed data during 1995-1997 in Daejeon city. As the analysis of observed data, the 30.1% of them were over the drinking water quality standards in Daejeon city and the unfit ratios of each region were 36.4% at Dong-Gu, 32.3% Daedeog-Gu, 31.2% Jung-Gu, 30.0% Seo-Gu and 25.2% at Yusoung-Gu. It was found that the items over the drinking water quality standards were 24 items and all of the mean concentration of water quality items were under the drinking water quality standard except Fe and Mn in 1997. The mean concentration of Fe was $1.31mg/{\ell}$ over the water quality at Daedeog-Gu and that of Mn was $0.53mg/{\ell}$ at Jung-Gu. The concentrations of $NH_3$-N, Mn, Fe, Al and F were increased rapidly in 1997, so that the cause of increasing also must be examined closely. It was found that the rainfall and unfit ratio(unfit frequency/test frequency) of E-coli and bacteria had the hydrologic persistance. The coefficient of correlation between them was 0.525. On the rainfall over 100mm, it was 0.673 and on the rainfall over 150mm, it was 0.641. The correlation between E-coli and rainfall was higher than that between bacteria and rainfall.

  • PDF

A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area (일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구)

  • 김영규
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF

An Application of Toxicity Test to Water Management and Water Treatment (수질관리와 수처리에의 독성시험의 응용)

  • Kim, Berm-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.639-646
    • /
    • 2005
  • In this research, we tried to develop the application method to water management and treatment using toxicity test method. When we measure the toxicity of environmental samples, we have to decide whether we take some countermeasures to reduce the toxicity or not. The first issue is how to set these action levels in each bioassays. A new idea was attempted to authorize indirect approach of each bioassays through the response characteristics against mixture of chemicals in water quality standard. The significant response in the cell-growth-inhibition bioassay was detected for standards-mixture(STDs). For acute toxicity assay, STDs-based implicit correlation between risks to humans and bioassay data showed a rational approach to set action levels in practical management. A simple model was proposed to describe and predict the changes in the total toxicity based on the concentrations of toxic-controlling chemicals during the ozonation of landfill leachates. On the basis of this simple model, toxicity reduction was predicted for pre-aggregation treatment before ozonation and ozone concentration during the ozonation. The method proposed in this study would be useful in optimizing water treatment processes and their running conditions in terms of the toxicity reduction efficacy.

A Study on the Rainwater Quality Monitoring and the Improvement, Collection and Storage System (빗물 집수 및 저장 시스템 개선과 수질 분석 모니터링)

  • Kim, Chul-Kyung
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.353-362
    • /
    • 2011
  • In our nature, the utilization of rainwater is essential for healthy water recirculation. This is one of the solutions of the increment of impermeability surface according to the development of new cities; this study of the improvement of rainwater quality has been carried on through the improvement of collecting and restoring system of rainwater. The southwestern region of Daejeon City, the rainwater coefficient of run off was 0.40 and this number had computed to 0.59 after the development. After filtration of rainwater, the heavy metal (Cu, As, Cr, Fe, Mn) contents level were lower than underground water. Moreover, collected rainwater showed better quality than underground water in following criteria; hardness, permanganate consumption quality, chloride, evaporation residue, sulfates and nitrate nitrogen. This water quality met the gray water quality standards. The rainwater quality was still suitable to use as bathroom flushing and gardening after 100 days of storage. This study proved that modification (installation of cover with gutter to existing rainwater collection system, proper filtering, and installation of underground storage tank) of collection system could improve quality of water and maintain this approximately 100 days.

Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir (회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가)

  • Maeng, Minsoo;Shahi, Nirmal Kumar;Kim, Donghyeun;Shin, Gwyam;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Research on the development law of karst fissures and groundwater characteristic in Xintian County

  • Xin, Zhou;Tengfei, Yao;Can, Wang;Jian, Ou;Pengfei, Zheng;Kaihong, Chen;Xiting, Long
    • Membrane and Water Treatment
    • /
    • v.13 no.6
    • /
    • pp.303-312
    • /
    • 2022
  • The natural hydrology and geological conditions of Xintian County was investigated, the development law of regional karst fissures was studied, the groundwater was collected and tested through a large-scale collection of groundwater to obtain the change law of chemical characteristics and water quality characteristics of groundwater, and the water quality evaluation was carried out for the regional karst groundwater in this paper. The results show that, the whole area is dominated by carbonate rock distribution areas, and the distribution of water systems is relatively developed. The strata are distributed from the Lower Paleozoic Cambrian to the Cenozoic Quaternary, and contain multiple first-order folds. The regional karst dynamic action is strong, and many tunnels or caves of different scales were shown, which are conducive to the enrichment of groundwater. Karst groundwater is neutral and alkaline water, the water is clear and transparent with good taste, and meets the national drinking water hygiene standards. The content of toxic trace elements and fluoride in the water source is generally lower than the limit value specified by the national standard and the accumulated toxic heavy metals is never found. The overall water quality is of good quality and suitable for the development and utilization of various purposes.

Water Quality of Agricultural Groundwater in Western Coast Area and Eastern Mountain Area of Jeollabuk-do (전라북도 서부 해안지역과 동부 산악지역 농업용 지하수 수질 평가)

  • Jo, Jae-Yeong
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.3
    • /
    • pp.218-224
    • /
    • 2011
  • This study was conducted to estimate the water quality of agricultural groundwater well located in Buan-gun, Jinan-gun, Sunchang-gun, and Jangsu-gun of Jeollabuk-do. The groundwater samples were collected at 328 sites (Buan-gun: 158, Jansu-gun: 45, Sunchang-gun: 32, Jinan-gun: 93, respectively). We measured 4 kinds of general contaminants (pH, $NO_3-N$, $Cl^-$, and COD) and 10 kinds of specific contaminants (Cd, As, $CN^-$, Hg, phenol, Pb, $Cr^{+6}$, organophosphorus, trichloroethylene, and tetrachloroethylene). Generally, the level of general contaminants and specific contaminants in the agricultural groundwater was suitable for water quality standard in all sites for agricultural irrigation water. Exceptionally, chloride concentrations were exceeded water quality standard of agricultural groundwater at some sites in western coast area of Jeollabuk-do. Although water quality standards in agricultural groundwater have been suitable, the water contaminants of agricultural groundwater in western coast area were gradually increased than eastern mountain area.