• 제목/요약/키워드: Water Quality Improvement Plan

Search Result 89, Processing Time 0.087 seconds

Quality control plan for water leaks through step-by-step review of modular housing (모듈러 주택 단계별 검토를 통한 누수하자 품질관리 방안)

  • Cho, In-Su;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.169-170
    • /
    • 2023
  • Leakage defects account for a significant proportion of defect cases in modular homes. There are factors that can cause leakage defects at each stage, and quality control measures are required to minimize them. An improvement plan to prevent leakage defects was applied from the design drawings to the site of a modular public rental apartment complex in Sejong City 6-3, and a quality control plan was proposed to minimize leakage defects in the remaining process processes.

  • PDF

A Strategy for Improving the Sewerage Systems of Two Rural Areas in Gyeonggi Province (경기도의 2개 시.군 사례를 통한 농어촌지역 하수도 정비 추진 방안)

  • Moon, Chul-Hwan;Ahn, Ji-Hoon;Jang, Mi-Jeong;Lee, Sang-Hyup;Cho, Young-Moo;Kim, Yun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.6
    • /
    • pp.563-580
    • /
    • 2010
  • In 2009 the Korea Ministry of Environment announced 'A Comprehensive Plan for the Improvement of Sewer Service in Rural Area' aiming at reduction of the sewer service gap between urban and rural areas as well as improvement in the residential environment of the rural area. According to the plan, the sewer system supply rate for the rural area is expected to reach up to 75% until 2015 with the budget of 4.7 trillion won (Korean currency). It is not certain, however, that the increase in the sewer system supply rate will accompany improvement of water quality in receiving water because several veiled problems that can occur in small-scale sewer treatment plants are poorly addressed in the plan. In this study, those issues for the small-scale sewer treatment plants and their solutions were discussed based on a case study in which we investigated 19 treatment facilities at two rural regions in Gyeonggi province. This study also included strategies useful for the plan. From the results of investigation, some problems, e.g., high hourly variations but low in flowrates and low mass loading were commonly identified. Although operation parameters in sewer treatment plants require to be modified depending on the mass loading, most of the plants were operated with the initial design parameters which causes the decrease of removal efficiency. In the intensive diagnosis, we arranged and applied solutions (e.g., flow equalization, air on/off time control, etc) to the two selected plants and found out improvement of effluent water quality, especially organic matters (COD and SS) and T-N with better denitrification performance.

Future Direction of Water Quality Standards in Korea (우리나라 물환경 기준의 개선방향)

  • Lee, Jae-Kwan;Cho, Soon;Chung, Il-Rok;Hwang, Soon-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.737-747
    • /
    • 2006
  • Ministry of Environment (MOE) of Korea has been implementing the water quality management policy to focus on the control of organic matters (BOD and COD) for 28 years since 1978 when the water quality standards had been established. However, the government and the public have begun to recognize the necessity of creating the best water environment for people and aquatic life, and also formulating the various measures of water pollution, Consequently, MOE of Korea is establishing the basic plan of water environment management, with the vision of "Clean Water, Eco River 2015." The major targets of water environment management plan are to maintain ecosystem health and to protect water quality from various hazardous substances in water bodies. In order to achieve the major targets, it is essential to amend the water quality standards, which bring about the systematic management of various pollutants and healthy ecosystem. Introduction of the new techniques of water environment assessment is also prerequisite to maintain sustainable water environment. These can be accomplished under the consideration of following suggestions in environmental quality standards. First, several criteria should be complemented in water quality standards; they include the improvement of the current water quality classification system, the strengthening and supplement of relevant parameters considering human health in the standards, the introduction of biotic indices, and management standards on eutrophication. Secondly, it should be considered to introduce the biological water quality standards using biotic indices and the management standards for sediments. Lastly, it needs to introduce or develop an ecological status classification which could be used in the assessment of the water environment as a whole.

A Study on the Application and Assessment of Urban River Restoration in the Anyang River (안양천 도시하천 복원의 실행과 평가에 관한 연구)

  • Lee, Sam-Hee;Choi, Jung-Kwon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • The Anyang River which located in an urban area near Seoul had been managed focusing on supplying home and industrial water and preventing floods, coping with rapid industrialization and urbanization. Consequently, it was changed into a deadly river during 25 years. Its channel was straightened by concrete and water quality deteriorated to BOD 190mg/l. In addition, water quantity has been rapidly decreased and has been drying up. Also, as the river ecosystem, landscape, water-friendly function, and so forth were seriously deteriorated, people turn away from the urban river. From 2001, the master plan under the 10-year has been actively carried out centering on the preceding items, which are healthy river in which fishes inhabit, safe river free from floods and droughts, and pleasant river where citizens visit. As a result, its water quality was remarkably improved by BOD 5mg/l in 2005 and some upper zones were improved enough to allow people to swim. Moreover, various animals including fish and birds gather around the river. Now, the 'Anyang River Restoration Project' is recognized as the first comprehensive and systematic nature-friendly urban river improvement in Korea.

A Study on the Planning Elements for Ecological Restoration of Urban Stream through Present Condition Analysis - focused on the Yeocheon and the Mugeo stream - (현황분석을 통한 도시 소하천의 생태하천 계획요소에 관한 연구 -울산광역시 무거.여천천을 중심으로-)

  • Kim, Seong Cheol;Lee, Cheol Yeong
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.747-757
    • /
    • 2004
  • The objectives of this study were to investigate the physical, chemical, and structural characteristics of the stream, especially Mugeo and Yeochon which are being changed to ecological stream by Ulsan city, and to acquire the considerations such as the planning element and plan criteria of the streams for making ecological stream system. Water quality, water quantity, vegetation, in stream structures and facilities, and land usage of the streams were investigated and the build up capabilities of ecological stream for the two streams were also analyzed. Planning elements for restoration to ecological stream included physical and biological purification methods in water quality, short term water acquire alternatives in water quantity, and vegetation recovery plan and improvement of habitation environment in ecological system, respectively. Planing elements in physical structures and facilities also included recovery of concrete levee and removal and recovery of covered channel.

A Study on the Improvement of Water Quality according to the Pollution Management Plan of Seomjin River Water System (섬진강수계의 오염원 관리방안에 따른 수질 개선에 관한 연구)

  • Won, Chan-Hee
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.514-527
    • /
    • 2018
  • This study formed a scenario to improve a water quality by expecting and analyzing a water quality of Jeollabuk-do Seomjingang water system, so calculated a result. As a result, it was analyzed that a water quality is improved at 15.32 % of the maximum BOD, 7.17 % of T-N, and 62.86 % of T-P according to domestic and livestock cut amount by reinforcing discharge water of sewage disposal plant and improving pollutant management plans. It was analyzed that supplementing various cut plans such as establishment of efficient cut plans, plans to decrease pollution loading amount, plans to increase sewage disposal efficiently, pollutant decrease through an expansion of sewage disposal area, and energy recovery from animal dung of Total Pollutant Load Management System, and developing a study on more efficient improvement plans of water quality by considering natural increase and economic development are efficient in an improvement in a water quality.

A Study on the Quality Improvement of Raw-Water Using Submerged Biofilter (생물막공정에 의한 상수원수의 수질개선에 관한 연구)

  • Lee, Soo-sik;Ahn, Seung-seop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.81-94
    • /
    • 1999
  • This study aims at a proposal of the plan that can improve raw water quality by an experimental study using influent water of Nak-dong river, which has been used as raw water for drinking in U-city, through the establishment of the submerged biofilter process PILOT PLANT of media packing channel method. From the analysis of removal efficiency for each water quality item of the collected sample, following results are obtained. First of all, the removal rate of suspended material, BOD, COD, T-N, TOC, turbidity, and $NH_3$ -N appear 82%, 78%, 42%, 15%, 57%, 43%, 54%, and 55% respectively and it is known that the submerged biofilter process of media packing channel method takes effects on water quality improvement from the above analysis results of water treatment efficiency. And the analyzed results for water temperature, residence time, and activities of microorganism, which can be the factors affect on water quality improvement, are as follows. 1) The removal rate variation of SS, BOD, and COD attendant on water temperature change is examined and it is known that the removal rate increases at $13^{\circ}C$ or above. 2) The removal rate of SS, BOD, and COD attendant on residence time is most active in the range of 0~18hr, 0~1.8hr, 0~2.7hr respectively, so it is found that the removal rate becomes smaller after 2.7hr. 3) From the examination of microorganism activity with the abundance of normal bacteria, it is found that the floating bacteria decrease as the flow distance from raw water inflow point of PILOT PLANT increases, and the adhesive bacteria have no concern with the flow distance. And it its known that the biomass of fine algae decreases as the flow distance from the raw water inflow point of PILOT PLANT increases from the examination with Chl-a.

  • PDF

The Outline of Han River Basin Environmental master Plan Project (한강유역 환경보전 종합계획 사업의 개요)

  • 이선환
    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.1
    • /
    • pp.46-50
    • /
    • 1982
  • Following rapid industrial development and urbanization in Korea, there is a need for the Government to implement effective control of pollution and to undertake specific schemes in areas where pollution of the environment is severe. In response to this need, Government of Korea prepare Han River Basin Environmental Master Plan Project for water, air, solid waste to cover environmental protection of the Han River Basin. The Project area is approximately 27,000 sq. Km extending over Seoul, Kyunggi, Kwangwon, Chungbuk Province. The total population of Master Plan Project area is approximately 11.6 million, or one-third of the total population of Korea. There are about 8,000 industries, including those located in 16 industrial complexes, in the project area. The scope of work and terms of reference are the following: (1) A Summary of existing land use and forecasts for changes in land use by the year 2,000. (2) Emission inventories for air, waste water, and solid wastes. (3) Forecasts of future population growth patterns and pollution loadings. (4) Identification of specific projects needs to reduce pollution levels and satisfy the environmental quality standards. (5) A Program of enforcement to include (i) self monitoring, and (ii) governmental inspections and surveillance. (6) A program for quality improvement and quality assurance of environmental measurements. (7) Reports summarizing all data collected analyzed during the study. (8) Conceptual design and feasibility studies, including cost estimates, for needed pollution control projects. (9) A financial plan for future detailed design and construction of public facilities, for financial incentives to industry, and for user charges for industrial use of public treatment of disposal works.

  • PDF

Establishment of Role Between Central and Local Government for Implementation of Total Maximum Daily Load (수질오염총량관리제 시행에 있어서 중앙정부와 지방자치단체 간 역할정립)

  • Yi, Sang-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.378-383
    • /
    • 2011
  • The policy of total maximum daily load (TMDL) was adopted to manage water pollutants so as to keep the total amount of pollutants in the watersheds within established target water quality. While the TMDL was implemented in all four major river basins, various problems occurred. Even though the corrections for problems were conducted, the role between central and local government was not established exactly. This study was presented to suggest a role between central and local governments for effective implementation of TMDL. When the central government establishes the environmental criteria with water quality standards and pollutants in the main rivers, the local government should establish the level of target pollutants in the watershed. Also, the local government should be continuously implementing the water quality and flowrate monitoring of the tributaries to find out the degree of water quality improvement in the tributaries. Especially, the basic plan of TMDL for the whole watershed should be established by the river basin environmental office at the central government. The local government should be established the implementation plan of TMDL for the watershed where exceeds the established target water quality. The performance assessment of TMDL should be implemented every year to the water quality and flowrate monitoring of the tributaries for satisfaction assessment of target water quality in the watershed by the lower-lever government. The performance assessment report of TMDL included with an analysis of causes for the excess water quality in the watershed should be submitted to the river basin environmental office at the end of the TMDL planning period.

Water Quality Improvement Plans based on the Analysis of Pollutant Discharge Characteristics and Water Quality Modelling of Seokmun Reservoir Watershed (석문호 유역 오염물질 배출특성 분석 및 수질모델링에 기초한 수질개선방안 연구)

  • Choi, Moojin;Jung, Woohyeuk;Choi, Jaehun;Kim, Youngil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.10
    • /
    • pp.581-590
    • /
    • 2017
  • For effective improvement of water quality in Seokmun reservoir, this study implemented various analyses including the tributary water quality and flowrate monitoring, contamination of sediment, investigation of pollution source, selection of priority management target tributary by stream grouping method. The COD concentration of the majority of tributaries in Seokmun reservoir watershed was relatively higher than BOD concentration. The concentration of water pollutants regardless of water quality parameters in Yeokcheon, Dangjincheon, Sigokcheon, Baekseokcheon, small stream in Jinkwanri and Janghangri were higher than the other tributaries. The pollution sources in the Seokmun reservoir watershed were mostly distributed in the population, livestock, and industry. The pollutants, which located in Yeokcheon, Dangjincheon, Baekseokcheon, and small stream in Janghangri selected as priority management target tributary, should be preferentially reduced for improving the water quality in Seokmun reservoir. As the evaluation results of water quality in Seokmun reservoir for the effect of water quality improvement according to various scenarios using water quality model, it was found that the water quality in Seokmun reservoir due to the construction of a wastewater treatment plant for management of pollutants in the watershed would be satisfied the class V of water environment standard in reservoir.