• 제목/요약/키워드: Water Pressure

검색결과 6,417건 처리시간 0.033초

해수냉각시스템 성능에 미치는 냉매배관길이의 영향 (Effect of Refrigerant Pipe Length on Sea Water Cooling System Performance)

  • 윤정인;조영제
    • 수산해양기술연구
    • /
    • 제34권3호
    • /
    • pp.346-351
    • /
    • 1998
  • The purpose of this study is analyzing the performance of sea water cooling system under various refrigerant pipe length. In sea water cooling system, the increase of refrigerant pipe length cause increases of pressure drops. These pressure drops cause fresh gas in liquid pipe and increase specific volume in gas pipe outlet, so sea water cooling system capacity is decreased by decrease of refrigerant mass flow rate. Sea water cooling system capacity in refrigerant pipe length 70m is decreased more than 30% when compared with pipe length 10m and the decrease of the coefficient of performance is nearly 20%.

  • PDF

구기자(枸杞子) 전탕액(煎湯液)이 실험적(實驗的) 신성(腎性) 고혈압(高血壓) 백서(白鼠)의 혈압(血壓)과 혈장(血漿) Renin 활성도(活性度) 및 ANP 농도(濃度)에 미치는 영향(影響) (Effects of Lycii Fructus Water Extracts on the Blood Pressure, Plasma Renin Activity and Plasma Levels of Atrial Natriuretic Peptide in Two-Kidney One Clip Goldblatt Hypertensive Rats)

  • 이호섭;류도곤;윤용갑;유윤조
    • 대한한의학회지
    • /
    • 제17권1호
    • /
    • pp.37-46
    • /
    • 1996
  • The aim of this experiments was to investigate the effect of Lycii Fructus water extracts on the blood pressure, plasma renin activity and plasma levels of atrial natriuretic peptide in two-kidney one clip Goldblatt hypertensive rats. Systolic blood pressure was decreased significantly after administration of Lycii Fructus water extracts. Plasma levels of atrial natriuretic peptide was increased significantly after adminstration of Lycii Fructus water extracts. Plasma renin activity was not changed after adminstration of Lycii Fructus water extracts. Thease results suggested that the depressor response after adminstration of Lycii Fructus water extracts were related with the changes of the plasma levels of atrial natriuretic peptide.

  • PDF

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • 제2권2호
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

상수관망에서 누수탐지를 위한 역추적계산법 (Back Tracing Calculation Method for the Leakage Detection in Water Distribution System)

  • 권혁재
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.611-619
    • /
    • 2013
  • In this study, Back Tracing Calculation Method was developed to determine the leakage location and leakage amount. Previously developed determination method of monitoring location and newly developed Back Tracing Calculation Method were applied to the sample pipe network and real size pilot plant. After leakage was assumed in the pilot plant, leakage location and leakage amount could be traced by Back Tracing Calculation Method. From the results, it was found that Back Tracing Calculation Method can be applied for the leakage detection in water distribution system. Furthermore, this method can be applied for the pressure management or leakage detection as a pressure control method in water distribution system.

저감속 회수장비 시험조건에 따른 초음속 시험탄 감속특성에 대한 수치해석적 연구 (Numerical Studies on the Deceleration Characteristics of Supersonic Projectile According to the Test Condition Parameters in a Soft Recovery System)

  • 송민섭;김재훈
    • 한국군사과학기술학회지
    • /
    • 제23권5호
    • /
    • pp.485-493
    • /
    • 2020
  • Numerical analyses were performed using a one-dimensional Euler equation and Godunov Harten-Lax-Van Leer(HLL) Riemann solver in order to study the deceleration characteristics of a 155 mm projectile in a soft recovery system. The soft recovery system consisting of a series of pressure tubes is a system that decelerates the test projectile fired at supersonic speed using a high-pressure gas and filled water inside. Therefore, depending on the gas pressure and the amount of water filling, the deceleration and the exit velocity of the test projectile inside the pressure tube are determined. In this paper, the deceleration characteristics of the test projectile were analyzed according to the gas pressure and water mass filled.

과잉 간극 수압 모형 개발 및 적용 (Development and application of pore pressure generation 모형)

  • 한정우;이승찬;박두희
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.546-550
    • /
    • 2007
  • High excess pore water pressure may develop when loose saturated sand is subjected to earthquake excitation, resulting in reduction in the shear strength and stiffness, and ultimately can result in liquefaction. It is very important to accurately assess the level of the pore pressure generation for seismic design and to perform effective stress analysis. A simple numerical 모형 is developed for estimating the development of pore water pressure due to seismic loading. The method only uses two parameters and the length of the accumulated shear strain. The accuracy of the proposed 모형 is verified through a series of laboratory test data. Comparisons show that the modified 모형 is an improvement over existing 모형s.

  • PDF

메탄 하이드레이트의 부존 가능성과 평형조건

  • 류병재;허대기;선우돈;정태진;김현태;김세준;이호섭
    • 한국석유지질학회:학술대회논문집
    • /
    • 한국석유지질학회 1998년도 제5차 학술발표회 발표논문집
    • /
    • pp.56-65
    • /
    • 1998
  • Methane hydrate is ice-like solid compound consisting of mainly methane and water, and is stable under specific low temperature and high pressure conditions (HSZ : methane hydrate stability zone) that occurs in permafrost regions and in the ocean floor sediments. Geophysical survey was implemented in the southern area of the East Sea, and the HSZ of the study area is determined by the temperature, pressure and local heat flow obtained from the survey and well data. In the study area, methane hydrates could exist in the sediments below the water depths of about $300{\cal}m$, and the base of HSZ is about 600m beneath the seafloor. The acoustically blanking zones in the sediment and phenomena of gas seepage were detected from the seismic section. These sediments have the sufficient physical condition for the formation of methane hydrate. The temperature and pressure conditions were experimentally measured for the dissociation of methane and propane hydrates in Pure water. Equilibrium conditions of methane and propane hydrates were obtained in the pressure range up to 19050Kpa and 401.3Kpa. Under same temperature condition, propane hydrate was dissociated at lower pressure than that of methane hydrate.

  • PDF

다목적 유전자 알고리즘을 이용한 상수관망에서 스프링 서지 완화 밸브의 최적화 (Optimum design of direct spring loaded pressure relief valve in water distribution system using multi-objective genetic algorithm)

  • 김현준;백다원;김상현
    • 상하수도학회지
    • /
    • 제32권2호
    • /
    • pp.115-122
    • /
    • 2018
  • Direct spring loaded pressure relief valve(DSLPRV) is a safety valve to relax surge pressure of the pipeline system. DSLPRV is one of widely used safety valves for its simplicity and efficiency. However, instability of the DSLPRV can caused by various reasons such as insufficient valve volume, natural vibration of the spring, etc. In order to improve reliability of DSLPRV, proper selection of design factors of DSLPRV is important. In this study, methodology for selecting design factors for DSLPRV was proposed. Dynamics of the DSLPRV disk was integrated into conventional 1D surge pressure analysis. Multi-objective genetic algorithm was also used to search optimum design factors for DSLPRV.

Development of an automated system for water-hydraulic and leakage test of pressure vessels

  • Kim, Dong-Soo;Lee, Won-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권1호
    • /
    • pp.55-59
    • /
    • 2004
  • This study developed a fully automated test system for pressure vessels, containing such as oxygen, nitrogen, which is widely used in many industries. The pressure vessel test has three major parts including weight measurement test, water-hydraulic test and leakage test followed by cleaning and drying. The control system for these tests consists of three parts: a PLC, a monitoring system and a database management system. The PLC oversees overall control of test machines, while the monitoring system measures and displays weight, pressure, flow etc. for every situations, and the database management system stores test data. These three modules are designed to communicate with one another at 1 Hz frequency alerting problematic situations to the operator. The system has gone through actual field tests for verification of performances.

폴리부틸렌 이중관에서의 워터 햄머 현상에 관한 연구 (The Study of Water Hammer in Polybutylene Double Piping System)

  • 김용봉;양찬모;이용화
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.511-516
    • /
    • 2005
  • This study is to investigate the pressure wave characteristics and the maximum pressure rise generated by instantaneous valve closure at the end of the straightening polybutylene double piping system with header. Experiments were conducted under the following conditions: initial pressure $1{\sim}5$ bar, flow velocity $0.5{\sim}3.0$ m/s and water temperature $25^{\circ}C$.

  • PDF