• 제목/요약/키워드: Water Plant

검색결과 6,610건 처리시간 0.038초

Comparative performance evaluation of two UF pilot plants at the Alto da Boa Vista WTP (São Paulo, Brazil)

  • Oliveira, T.F.;Mierzwa, J.C.
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.175-185
    • /
    • 2011
  • Ultrafiltration is an emerging technology for drinking water treatment because it produces better water quality as compared with conventional treatment systems. More recently, the combination of UF technology with other processes in order to improve its performance has been observed. These associations aim to maximize the contaminants removal and reduce membrane fouling. The operational performance of contaminants removal and water production of two UF pilot plants was compared. The first plant (Guarapiranga) was fed with raw water and the second plant (ABV) with pre-treated water by the coagulation, flocculation and sedimentation processes at Alto da Boa Vista WTP (Sao Paulo, Brazil). Both units operated continuously for approximately 2,500 hours, from September/2009 to January/2010. The results showed that the ABV UF pilot plant was able to operate at higher specific fluxes (6.2 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$) than Guarapiranga (3.1 $L.d^{-1}.m^{-2}.kPa^{-1}$ @ $25^{\circ}C$). However, the number of chemical cleanings conducted in both pilot units during the considered operation period was the same (4 chemical cleanings for each plant), which shows that the pre-treatment reduced the membrane fouling. The water quality at ABV for all the variables analyzed was better, but the feed water quality was also better due to pretreatment. The rejection values for the different contaminants were higher at Guarapiranga mainly because of a pollution load reduction after pre-treatment at ABV. Even with the better performance of the ABV UF pilot plant, it is necessary to take into consideration the complexity of the complete treatment system, and also the costs involved in the construction and operation of a full-scale treatment unit.

전력계통안정화장치(PSS) 수력발전소 적용분석 (The Application Analysis of Power System Stabilizer in Hydraulic power plant)

  • 옥연호;임재일;박지군;곽원구;이광연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.63-65
    • /
    • 2007
  • Recently with increase consumption of electric power, the scale of the electric system becomes bigger and complex. Then, it is increasing the hardship in the operation of electric system and the continuance of stability. Especially, as the differences between demand and supply in electric power keeping low frequency oscillating attenuation from electric power have been very important in the continuance part of stability. The more control time of electricity system is getting faster with digitalization the more stability of electricity system is getting worse. As solutions of these problems, by establishing Power System Stabilizing Controller putting PSS output signal and putting damping to vibration of the rotor at generators's AVR in area where is oscillated, We are willing to contribute the electricity system by holding in generator output vibration.

  • PDF

시화조력발전소 수차발전기 제어시스템의 동적 특성 해석 (Dynamic Characteristic Analysis of Water-Turbine Generator Control System of Sihwa Tidal Power Plant)

  • 안상지;반우현;박철원
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.180-185
    • /
    • 2012
  • Tidal power is one of new and renewable energy sources. The seawater is stored inside a tidal embankment built at the mouth of a river or bay, where tides ebb and flow. The water turbine-generators produce power by exploiting the gap in the water level between the water outside and inside the embankment. Tidal power plant is a large plant that is installed on the sea. And then, the facility's operations and a separate control system for monitoring and maintenance is required. However, this plant predictive control of building systems and technologies have been avoided the transfer of technology from advanced global companies. Accordingly, the control system for core technology development and localization is urgently needed. This paper presents modeling and simulation using by PSS/E about generator, governor, exciter, and power system stabilizer for control system in Sihwa tidal power plant to improve the efficiency and develope of core technology. And the dynamic characteristics of governor and exciter were analyzed.

인삼의 연생, 생육시기 및 식물체 부위별 수용성과 불수용성 탄수화물 함량과 합성저장량 비교 (Comparative Analysis on Concentration and Synthetic Amount of Water Soluble and Water Insoluble Carbohydrates with Different Plant Tissues, Growth Stages and Years Old of Panax ginseng C. A. Meyer)

  • 박성용;안복주;안희정;이경아;허수정;정햇님;송범헌
    • 한국약용작물학회지
    • /
    • 제23권4호
    • /
    • pp.292-297
    • /
    • 2015
  • This study was carried out to have the basic and applied informations relating to develop the cultivation methods and to increase the productivity and quality of ginseng. 1 to 6 year old ginsengs of Jakyung cultivar were cultivated and the content and synthetic amount of carbohydrates were investigated with different plant tissues, growth stages, and years old. The concentration of total carbohydrates at six year old ginseng including water soluble and water insoluble carbohydrates was about 18.9%, 42.9%, and 43,6% in leaves, tap roots, and lateral roots, respectively. Water soluble carbohydrate of tap and lateral roots was slightly decreased from August until September, and then increased on November, whereas its water insoluble carbohydrate was increased from August to September and then decreased on November. Comparing with the content of carbohydrates of 1 to 6 year old ginsengs, it was continuously increased from one year old ginseng until five year old ginseng, however it was not increased much in six year old ginseng. The highest content of carbohydrates was at five year-old in all tissues of ginseng. Water soluble and water insoluble carbohydrates were significantly shown different in leaves, stems, tap roots, and lateral root at different growth stages and with different years old. The content of water soluble carbohydrate in the leaves was remarkedly higher compared to that of water insoluble carbohydrate, while in the root the content of water insoluble carbohydrate was clearly higher compared to the water soluble carbohydrate. Comparing with the synthetic amount of carbohydrates, water soluble carbohydrates was higher in the shoot than that in the root, whereas water-insoluble carbohydrates higher in the root than that in the shoot. Carbohydrates which would be utilized in ginseng tissues for short and long-term periods as major energy were appeared differently in between shoot and root, with different growth stages, and years old.

Superoxide Dismutase와 Ascorbate Peroxidase를 엽록체에 과발현하는 형질전환 담배의 수분스트레스에 대한 반응 (Responses of Transgenic Tobacco Plants Overexpressing Superoxide Dismutase and Ascorbate Peroxidase in Chloroplasts to Water Stress)

  • 최선미;권석윤;곽상수;박용목
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.79-84
    • /
    • 2001
  • To assess resistance of transgenic tobacco plants which overexpress superoxide dismutase (SOD) and ascorbate peroxidase (APX) in chloroplasts to water stress, changes in leaf water potential, turgor potential, stomatal conductance and transpiration rate were measured. Leaf water potential in all plants remained high up to day 4 after withholding water but thereafter decreased markedly. In spite of a remarkable decrease in leaf water potential, some of transgenic plants maintained higher turgor potential compared with control plant on day 12. In particular, the transgenic plant expressing MnSOD showed an outstanding maintenance in turgor pressure by osmotic adjustment throughout the experiment, resulting in high stomatal conductance and transpiration rate. However, among transgenic plants, osmotic potential was reduced more effectively in multiple transformants such as the double transformant expressing both MnSOD and APX, and the triple transformant expressing CuznSOD, MnSOD and APX than single transformants. Consequently, further research is needed to get general agreement on the tolerance of transgenic plants to water stress at different growth stages for each transgenic plant.

  • PDF

비상시 열원중단에 따른 데이터센터의 냉각시스템 열성능 평가에 관한 사례연구 (A Study on Thermal Analysis for a Data Center Cooling System under Fault Conditions at a Chilled Water Plant)

  • 조진균;강호석
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.178-185
    • /
    • 2016
  • This study describes the analysis of a 20 MW chilled water plant used for the IT cooling of a recently constructed data center in Korea. The CFD model was developed with the aim of evaluating the impact of problems such as chiller failure on the water and air temperatures in the cooling system. The numerical model includes the chilled water hydraulic network and individual water-to-air CRAC units. The coupling between the IT server room air temperature levels and the cooling plant has enabled a full assessment of the cooling system design in response to system fault conditions to be performed. The paper examines an emergency situation involving the failure of the cooling plant, and shows how the inherent thermal inertia of the system along with additional inertia achieved through buffer systems allowed a suitable design to be achieved.

스마트 워터 그리드 내에서 워터 블렌딩을 고려한 역삼투 해수담수화 플랜트 설계 (Design for seawater reverse osmosis plant using water blending in smart water grid)

  • 이홍주;박한배;우달식;김수한
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.89-96
    • /
    • 2015
  • Smart water grid is a water network with communication to save water and energy using various water resources. In smart water grid, water product from the various sources can be blended to be supplied to end-users. The product water blending was reported by literatures while feed water blending has been rarely reported so far. In this work, a commercial reverse osmosis (RO) system design software provided by a membrane manufacturer was used to elucidate the effect of feed water blending on the performance of seawater reverse osmosis (SWRO) plant. Fresh water from exisiting water resource was assumed to be blended to seawater to decrease salt concentration of the RO feed water. The feed water blending can simplify the RO system from double to single pass and decrease seawater intake amount, the unit prices of the RO system components including high pressure pump, and operation risk. Due to the increase in RO plant capacity with the feed water blending, however, the RO membrane area and total power consumption increase at higher water blending rates. Therefore, a specific benefit-cost analysis should be carried out to apply the feed water blending to SWRO plants.

농업용수 수질기준 T-P 항목에 대한 검증실험(I) (An Evaluation study on Total Nitrogen(T-P) Item of Agricultural Water Standards)

  • 최선화;김호일;윤경섭;이봉훈
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.603-606
    • /
    • 2003
  • This study was carried out to investigate the effects of T-P concentrations in irrigation water on the growth, yield, and grain quality of rice. It acquire fundamental knowledges to set up irrigation water quality standards. The pot experiment was conducted with 5 treatments using irrigation waters. It consisted of various total phosphorus concentrations(control, 1, 2, 5, 10mg/L) and replicated four times with randomized block design. The results of this study showed that as T-P concentrations in irrigation water increases, plant height tended to increase. Dry weight of rice plant at T-P 10mg/L was significantly higher than the control. However, T-P in irrigation water did not affect plant height, tiller number, plant dry weight, yield, and quality of rice.

  • PDF

원자력발전소 기기냉각수계통의 판형열교환기 적용성 (Applicability of Plate Heat Exchanger to Plant Cooling Water Systems in Pressure Water Reactor)

  • 임혁순
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.505-510
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. Due to the increased electric power, In Nuclear Power plant huge quantities of heat are generated in the thermo-dynamic process used for producing electrical energy. So, There is considerationly additional cooling, Heat transfer area and increased cooling water of Heat Exchanger which take care of the different smaller cooling duties within the nuclear power plant. We review applying to PRE instead of Shell-and-Tube Heat exchanger. In this paper, we describe the major design features of PRE, Comparison between a PHE and a Shell-and-Tube Heat Exchanger, and then Applicability of Plate Heat Exchanger in Nuclear Power Plant Component Cooling water systems.

  • PDF

수력발전소 물 공급 설비에 대한 FTA 모형 (FTA Modeling of Water Supply System for Hydro-power Plant)

  • 전태보;권창섭
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.145-155
    • /
    • 2006
  • High level of reliability in facility operation is specifically required these days. The goal of this study is to secure a methodology for reliability analysis of hydro-power plant so that an appropriate decision for operation and investment can be made. Fault tree analysis of water supply system within hydro-power plant has been performed in this study. We briefly examined the electric power generation facility and water supply system. We then developed fault tree for the water supply system based on failure modes and effects analysis. We conclude this study and provided future research areas.

  • PDF