• Title/Summary/Keyword: Water Plan

Search Result 1,687, Processing Time 0.025 seconds

Investigation and Analysis of Unit Industrial Water Usage Considering Latest Industrial Trend (최신 산업동향을 고려한 공업단지 사용량 원단위 분석 연구)

  • Kim, Kibum;Yu, Youngjun;Choi, Woojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.447-457
    • /
    • 2017
  • This study derived the unit of industrial water usage reflecting the latest industry trends. Available for establishing plans such as the master plan for water supply system and analyzed changes in the basic unit by a comparison with the current basic unit values. This study analyzed 4,038 samples with a sampling error of less than 1.5 % at the 95 % confidence level after removing outliers according to a log-normal distribution. As a result, the unit of industrial water usage per site area in the whole manufacturing industry was 7.11 m3/1,000m2/d. The ten industrial categories (C10, C13, C20, C21, C22, C25, C27, C30, C32, C33) showed a similar unit value compared to before, and the four industrials categories (C11, C17, C22, C31) showed a more unit value than before. With regard to the nine industrial categories (C14, C15, C16, C18, C19, C24, C26, C28, C29), the unit value decreased. Cases that companies examined before were the same as the companies examined in this study were analyzed. The result that the changes in the unit industrial water usage were reasonable was obtained. However, in some industrial categories (C17, C14, C24, C29), the unit value was changed by a small number of companies with large-scale water use or unit value of sampling had a large deviation. It was considered necessary to survey them periodically. The unit of industrial water usage derived by the survey in this study reflects the current industrial trends in 2016. Water use in manufacturing companies has continuously changed by the development of manufacturing technologies and simplification of manufacturing processes. In order to deal with this, it is considered necessary to survey the usage of industrial water periodically from a long-term perspective.

Effect of Residual Chlorine Concentration on Water Pipe Corrosion and Corrosion Control Plan (수도관 부식에 대한 잔류염소 농도 영향 및 부식제어 방안)

  • Han, Keum-Seok;Park, Ju-Hyun;Park, Young-Bok;Kim, Seong-Jae;Kim, Hyen-Don;Choi, Young-June;Choi, In-cheol;Hong, Seong-Ho
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • Langelier Index (LI) is used as a tap water corrosiveness index. Residual chlorine in tap water induces corrosion inside water pipes. This study takes a deeper look into the effect of residual chlorine in water pipes. Comparison between tap waters of Y and K water treatment plant (WTP) shows that the LI index of K WTP is lower than that of Y. However, the corrosion rate of Y WTP is higher than that of K WTP. This means that the higher the concentration of residual chlorine in tap water, the higher the corrosion rate of pipe materials. When calcium hydroxide was added to tap water, the corrosiveness index was improved and thus the corrosion rate reduced. It is possible to increase the disinfection efficiency by increasing the duration of residual chlorine and suppressing the rust generation of water pipes and to supply minerals. A guideline for corrosion control with residual chlorine should be set up. The effects of residual chlorine should be included in the corrosiveness index of tap water.

Comparison of Water Supply Reliability by Dam Operation Methods (댐 운영방식에 따른 이수안전도의 비교)

  • Choi, Si Jung;Lee, Dong-Ryul;Moon, Jang Won
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.6
    • /
    • pp.523-536
    • /
    • 2014
  • A water supply reliability is mainly influenced by water demand, reservoir storage, and inflow change caused from drought. The water supply reliability can vary depending on the method of dam operation. In Korea, the deficit-supply method which complements water deficit as water shortage occurs in downstream areas has been used for the national water resources master plan using K-WEAP, but the prime flow method, an alternative approach, would show different results of water supply reliability in comparison to the deficit-supply method. The objective of this research is to compare and analyze differences in water supply reliability according to dam operation methods. These results can be used to re-evaluate water supply reliability of dam in a circumstance considering steady dam release for instreamflow in downstream and hydroelectric power generation.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

Economic analysis of irrigation facilities for securing water for field crops

  • Hyung Jin Shin;Jae Young Lee;Jae Nam Lee;Han Na Lee;Sang Hyeon Park;Bum Soo Shin;Sang Sun Cha;Se Myung Kwon;Jung Il Seo;Chan Gi Park
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.785-798
    • /
    • 2023
  • Considering irrigation facilities are currently insufficient and drought vulnerability due to climate change is high, efficient measures are required to secure water supply for field crops. This study, therefore, calculated the water shortage to secure water for representative field crops. An economic analysis was further conducted by comparing the production income to the input cost for each method. Here, five distinct regions were selected to represent each crop-Cheongyang-gun for chili peppers, Yesan-gun for apples, Dangjin-si for cabbages, Seosan-si for garlic, and Goesan for beans. The regions with insufficient water supply were estimated by calculating the water requirements and the supplied water from public groundwater wells for each area. A comprehensive set of four scenarios was presented as a strategy to ensure water security and manage irrigation facilities. These scenarios comprised the maintenance of existing groundwater wells, the construction of new water storage tanks, the installation of additional groundwater wells, and the utilization of surface water. B/C (benefit/cost) analysis was conducted for each scenario. As a result, the construction of water storage tanks was selected as a facility and water management plan in Cheongyang-gun, Dangjin-si, and Seosan-si. The analysis additionally indicated the economic viability of installing surface water utilization facilities in Yesan-gun and developing water storage tanks and groundwater (aquifer) wells in Goesan-gun. The results of this study are considered to serve as foundation data that may be utilized in the selection of water management plans for drought-prone areas in the future.

A Proposal on Waterfront Development Reflecting the Placeness of Pusan Port Area (부산항의 장소적 특성에 따른 워터프런트 개발방향)

  • 조은석;이호수;조용수
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.109-117
    • /
    • 2000
  • This study aims at advancing waterfront of Pusan Port and attempting to establish an identity through studying characteristics of place in Pusan Port. The place is consisted of two elements ; orientation and identity, which is expressed clearly the environmental totality including the character and space. The urban waterfront is also one of the place pattern, and that is consist of land area, water area, and transit zone combining two areas. Although there are a lot of primary factors to be able to make the most of the character and identity in Pusan port, badly planned development prevents the plan promoting the sense of place in urban waterfront. The point in the waterfront development plan of Pusan Port is how to secure aminities based on Identity and Orientation; node, landmark, edge, path, district. The result of this study is for planners to develop more and systematic approaches which could utilize waterfront.

  • PDF

The Land Canal Construction of Korea in the Vision of the National Land Development (국토개발측면에서 구상해본 한국의 "내륙운하"건설)

  • Chung, Moo-Yong
    • Journal of the Korean Professional Engineers Association
    • /
    • v.39 no.6 s.189
    • /
    • pp.51-56
    • /
    • 2006
  • The important role of canal is moving goods and the canals from all over the world has contributed much to method of transporting goods. But, the canal system accounts rfor 25% of the total moving goods. One of its main goals is to reduce overland transportation costs were 30% more expensive than moving goods over water. We plan to build a Korea inland canal system and need to from a scheme of building a multi canal. We should consider positive aspect of this plan, on the other hand a study of the conal's environmental impact is required prior to beginning any construction. Finally, offer our opinion on the vision of Korea inland canal that aspect5 of national land development.

  • PDF

A Study on Environment Change According to Land Development Plan of Cheju Island Using GSIS Technique (GSIS를 이용한 제주도 국토개발에 따른 환경변화에 관한 연구)

  • 이병걸;강인준
    • Journal of Environmental Science International
    • /
    • v.9 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • The purpose of this paper is to present the environment change of Cheju Island as land development process using GSIS(Geo-Spatial Information System) technique. We implemented the process based on the maps of soil color, underground water pollution points, land use, land development planning and land sight seeing supported by Cheju Province Office. To use the maps for GSIS data, first we transformed the picture data of the office into raster structured picture data using scanner. Second, the coordinate system was added to raster data using 1/50000 geographic map. Third, we estimated land planning process using GSIS technique(overlay and reclass technique). The results showed that land development effected the natural environment(forest, green field, farm land). However, the chemical pollution and land sight seeing was not so much effected by the land development that was found.

  • PDF

A Study on the Importance Analysis of Environmentally-Friendly Planning Factors Using Analytic Hierarchy Process (계층분석법을 이용한 환경친화 계획요소의 중요도 분석에 관한 연구)

  • 류지원;김정환;정응호
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.897-903
    • /
    • 2003
  • This study focuses on importance level analysis of environmentally-friendly planning factors using Analytic Hierarchy Process(AMP). This study verify different planning principle makes comparison matrix by a relative comparison value, verified consistency after yield weight to analyze more objective importance for apartment complex estate environmentally-friendly planning factor. In order to decide importance of apartment complex estate environmentally-friendly planning factors multiplying weight of verified planning principle with weight of planning factors. The results are as follows; First, importance of preservation of green tract of lands, Preparation of Biotop, Tree planting of sites, Propriety of development density high except Circulation and practical use of water. Next, valued planning factors constituent appeared to Energy efficient building plan, Rubbish recycling, thermal utilization of solar energy, Artificial tree planting of buildings etc. importantly. Finally, plan constituent that importance is underrated most appeared by Practical use of building materials and equipment, Centralization of energy and resources, Preservation of corridor etc.

Water-Simulant Facility Installation for the Sodium-Cooled Fast Reactor KALIMER-600 and Global Flow Measurement (소듐냉각고속로 KALIMER-600 축소 물모의 열유동 가시화 실험장치 구축 및 거시 유동장 특성 측정)

  • Cha, Jae-Eun;Kim, Seong-O
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.54-62
    • /
    • 2011
  • KAERI has developed a KALIMER-600 which is a pool-type sodium-cooled fast reactor with a 600MWe electric generation capacity. For a SFR development, one of the main topics is an enhancement of the reactor system safety. Therefore, we have a long-term plan to design the large sodium experimental facility to evaluate the reactor safety and component performance. In order to extrapolate a thermal hydraulic phenomena in a large sodium reactor, the thermal hydraulics phenomena is under investigation in a 1/$10^{th}$ water-simulant facility for the KALIMER-600. In this paper, we shortly described the experimental facility setup and the measurement of the isothermal global flow behavior. For the flow field measurement, the PIV method was used in a transparent Plexiglas reactor vessel model at around $20^{\circ}C$ water condition.