• Title/Summary/Keyword: Water Pipeline

Search Result 383, Processing Time 0.031 seconds

Extended inverse impedance method for multiple branches or loops pipeline systems (복합 관수로에서 인버스 임피던스 확장연구)

  • Dongwon Ko;Sanghyun Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.437-446
    • /
    • 2023
  • We propose a transient evaluation scheme using a pressure measurement in a complicate pipeline systems. Conservation of mass and momentum equations in time domain can be transformed into a pressure head and flowrate relationship between upstream and downstream point in frequency domain. The impedance formulations were derived to address measured pressure at downstream to evaluate of flowrate or pressure head at any point of system. Both branched pipeline element and looped pipeline element can be generally addressed in the platform of the basic reservoir pipeline valve system. The convolution of time domain response function with measured pressure head from a downstream point provides flowrate or pressure head response in any point of the designated pipeline system. The proposed method was validated through comparison between traditional method of characteristics and the proposed method in several hypothetical systems.

Sensitivity Analysis of Pipeline Rehabilitation Model According to Initial Year Break Rate and Growth Rate Coefficient (초기파손율과 성장계수에 따른 상수관 개량모델의 민감도 분석)

  • Chung, Won-Sik;Kim, I-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1302-1306
    • /
    • 2005
  • This study has Performed to develop rehabilitation model for determination of optimal rehabilitation time on the Cast Iron Pipes (CIP) with diameter less than 300 mm in water pipeline network and to analysis the sensitivity on the rehabilitation times of developed model. In the result from the application of the field, the renovation time was faster about 10 years than the replacement time. Especially, as the difference between rehabilitation and replacement time on E-CIP was about from 3 to 5 years, and it was thought that the replacement was effective on E-CIP. To sensitivity analysis, the discount rate of coefficient was fixed at 0.08, and the values of initial year break rate(N($t_o$) and growth rate coefficient(A) were adjusted in values of 0.0009, 0.0018, 0.0027, and 0.05, 0.10, 0.15 respectively. When the values of N($t_o$) and A was increased, the results from the time of rehabilitation and replacement was faster It was thought that N($t_o$), 0.018 was reliable values on the applied pipeline through the result of the study. In case of A, the values of A above 0.1 was thought to be Proper.

  • PDF

Transient Analysis and Experiment Considering Unsteady Friction and Leakage in a Pipeline System (단일관망에서 누수효과를 고려한 천이류 분석 및 실험)

  • Lee, Mi-Hyun;Song, Yong-Sok;Kim, Sang-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1395-1399
    • /
    • 2006
  • The current paper focuses the analysis of leakage detection in water pipeline systems by means of the transient analysis. In order to obtain pressure variation for evaluation the existing methodology, an extensive experimental process has been carried out in a single pipeline system. Several experimental tests were performed with and without a leakage in the system. Using the unsteady friction and improved unsteady friction factors, reasonable match between the computed and measured pressure were presented on the condition of the flow situations. The transient method attempts to estimate the leakage in water pipelines using observed pressure data collected during transient events on the system.

  • PDF

Comparison of the Node Method and the Pipeline Method for the Analysis of Water Distribution Systems (배수관망해석(配水管網解析)에 있어서 절점유출법(節点流出法)과 관로유출법(管路流出法)의 비교(比較))

  • Lee, Sang Mok;Lyu, Jong Hyun;Hyun, In Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.85-93
    • /
    • 1996
  • This study is to make a comparison between the node method and the pipeline method for the analysis of the water distribution systems. For these purposes, the two methods were applied to a pipeline system in series, an artificial distribution network and a real distribution network. The results are as follows. 1. The difference between the results of the two methods was increased with the increase of the hydraulic gradient and the length between two adjacent nodes. 2. When all pipe lengths between two adjacent nodes were larger than 200~300m and have the steep hydraulic gradient, it was found that the results of the two methods showed high differences. 3. The difference between the results of the two methods were negligible in the case of the real distribution system in which only 12% whole pipelines were longer than 30m and the longest pipe length was 850m.

  • PDF

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

Expert System for Emergency Decision Making for Metro Water Supply Systems (광역상수도 시설의 비상시 의사결정을 위한 전문가시스템)

  • Kim, Eung Seok;Kim, Joong Hoon;Baek, Chun Woo;Lee, Jung Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.103-110
    • /
    • 2007
  • An efficient operational strategy using expert system for metro water supply systems in case of emergency situations is developed in this study. The emergency situations of the water supply systems are classified into three categories : pipeline system accident, machinery and electric facility accident and water quality accident. A PC-based expert system is developed using CLIPS for Seoul metro water supply system, Phase 1 & 2 system and Phase 3 & 4 system. Broad professional knowledges and experiences from the experts in the water supply systems have been collected systematically to construct the knowledge base. Decision-making in case of an emergency is based upon the professional knowledge so that a rational and efficient operational management can be available even in the absence of experienced expert. Especially the expert model developed in this study also provides a guide for pumping operation in case of pipeline accident to confirm that the proper pressure to all nodes in the system is supplied. The pipe network simulator KYPIPE has been consecutively executed by trial and error fashion for each pipeline in the system. The results from KYPIPE were included in the knowledge base to supplement the knowledge of the field engineers.

A Study on Greenhouse Farmers' Willingness to Pay of Agricultural Water Supply through Pipeline (관수로 농업용수 공급에 대한 시설재배 농가의 비용 지불의사 연구)

  • Lim, Cheong-Ryong;Park, Seong-gyeong;Chung, Won-ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.2
    • /
    • pp.109-114
    • /
    • 2018
  • In this study, we estimate the greenhouse farmers' willingness to pay of agricultural water supply through pipeline. First, in the questionnaire design, orthogonal design and block design were used to enhance the ease of survey. Second, the theoretical model was constructed through the setting of the probability utility function, and the parameters were estimated by using the conditional logit model. Third, all of the estimation coefficients were statistically significant at the 1% significance level. The results of analysis are summarized as follows. First, the probability of selection is increased when maintenance is carried out by Korea Rural Community Corporation or local government. Second, the probability of selection is increased when agricultural water supply through pipeline is higher than the current level. Third, if the Korea Rural Community Corporation carries out maintenance management, the marginal willingness to pay is 44 won per ton. And if the local government carries out maintenance management, the marginal willingness to pay is 25 won per ton. Fourth, according to the quality level of agricultural water supply, the marginal willingness to pay is 101 won, 114 won and 120 won per ton, respectively. This study can be used as a basic data on the cost setting for agricultural water supply through pipeline.

Data Analysis of First Leak Time of Water Pipeline (상수도용 Pipeline의 누수고장 자료 분석)

  • Na, Myung-Hwan;Ham, Sang-Min
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.213-224
    • /
    • 2011
  • In this paper, we analyze statistically the data set of first leak time of water pipeline. We classify first the leak time data by pipe type, location, diameter of pipe and, length of pipe. We perform the analysis of variance to indicate that there are significant difference of mean of the time between levels of the factor and also compare the distribution of levels using the multiple box-plot. When there are the difference of the mean, we perform the least significant test to find out what levels of the facor has a different mean.

A comprehensive approach to flow-based seismic risk analysis of water transmission network

  • Yoon, Sungsik;Lee, Young-Joo;Jung, Hyung-Jo
    • Structural Engineering and Mechanics
    • /
    • v.73 no.3
    • /
    • pp.339-351
    • /
    • 2020
  • Earthquakes are natural disasters that cause serious social disruptions and economic losses. In particular, they have a significant impact on critical lifeline infrastructure such as urban water transmission networks. Therefore, it is important to predict network performance and provide an alternative that minimizes the damage by considering the factors affecting lifeline structures. This paper proposes a probabilistic reliability approach for post-hazard flow analysis of a water transmission network according to earthquake magnitude, pipeline deterioration, and interdependency between pumping plants and 154 kV substations. The model is composed of the following three phases: (1) generation of input ground motion considering spatial correlation, (2) updating the revised nodal demands, and (3) calculation of available nodal demands. Accordingly, a computer code was developed to perform the hydraulic analysis and numerical modelling of water facilities. For numerical simulation, an actual water transmission network was considered and the epicenter was determined from historical earthquake data. To evaluate the network performance, flow-based performance indicators such as system serviceability, nodal serviceability, and mean normal status rate were introduced. The results from the proposed approach quantitatively show that the water network is significantly affected by not only the magnitude of the earthquake but the interdependency and pipeline deterioration.

A study on the economical life of large-diameter water pipe: case study in P waterworks (대구경 상수도관로의 경제적수명 산정 연구: P상수도 사례연구)

  • Kim, Kibum;Seo, Jeewon;Choi, Taeho;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2018
  • This study develops a model to estimate the economic life of the large-diameter water supply pipeline in Korea by supplementing existing methods used to perform similar calculations. To evaluate the developed methodology, the model was applied to the actual target area with the conveyance pipe in P waterworks. The application yielded an economic life computation of 39.7 years, considering the cost of damages, maintenance, and renewal of the pipeline. Based on a sensitivity analysis of the derived results, the most important factor influencing the economic life expectancy was the predicted failure rate. The methodology for estimating the economic life of the water supply pipeline proposed in this study is one of the core processes of basic waterworks facility management planning. Therefore, the methods and results proposed in this study may be applied to asset management planning for water service providers.