• Title/Summary/Keyword: Water Network

Search Result 2,040, Processing Time 0.026 seconds

Automatic Control of Coagulant Dosing Rate Using Self-Organizing Fuzzy Neural Network (자기조직형 Fuzzy Neural Network에 의한 응집제 투입률 자동제어)

  • 오석영;변두균
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1100-1106
    • /
    • 2004
  • In this report, a self-organizing fuzzy neural network is proposed to control chemical feeding, which is one of the most important problems in water treatment process. In the case of the learning according to raw water quality, the self-organizing fuzzy network, which can be driven by plant operator, is very effective, Simulation results of the proposed method using the data of water treatment plant show good performance. This algorithm is included to chemical feeder, which is composed of PLC, magnetic flow-meter and control valve, so the intelligent control of chemical feeding is realized.

A Study on Coagulant Feeding Control of the Water Treatment Plant Using Intelligent Algorithms (지능알고리즘에 의한 정수장 약품주입제어에 관한 연구)

  • 김용열;강이석
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.1
    • /
    • pp.57-62
    • /
    • 2003
  • It is difficult to determine the feeding rate of coagulant in the water treatment plant, due to nonlinearity, multivariables and slow response characteristics etc. To deal with this difficulty, the genetic-fuzzy system genetic-equation system and the neural network system were used in determining the feeding rate of the coagulant. Fuzzy system and neural network system are excellently robust in multivariables and nonlinear problems. but fuzzy system is difficult to construct the fuzzy parameter such as the rule table and the membership function. Therefore we made the genetic-fuzzy system by the fusion of genetic algorithms and fuzzy system, and also made the feeding rate equation by genetic algorithms. To train fuzzy system, equation parameter and neural network system, the actual operation data of the water treatment plant was used. We determined optimized feeding rates of coagulant by the fuzzy system, the equation and the neural network and also compared them with the feeding rates of the actual operation data.

Hydraulic Analysis of Urban Water-Supply Networks in Marivan

  • Tavosi, Mohammad Ghareb;Siosemarde, Maaroof
    • Industrial Engineering and Management Systems
    • /
    • v.15 no.4
    • /
    • pp.396-402
    • /
    • 2016
  • In this study, hydraulic analysis of water-supply networks in Marivan was performed by modeling. WATERGEMS was used for modeling and it was calibrated using existing rules and regulations. The purpose of this research is modeling urban water network and its analysis based on hydraulic criteria and meeting pressure conditions at the nodes and complying the economic speed. To achieve this goal, first the pipelines of city streets was designed in AutoCAD on a map of the city. It should be mentioned that it was tried to prevent from creating additional loops in the network and the optimal network was designed by a combination of annular and branch loops. In the next step, the pipes were called in WATERGEMS and then we continue the operation by the allocation of elevation digits to the pipes. Since the topography of this city is very specific and unique, the number of pressure zones was increased. Three zones created only covers about 20% of the population in the city. In this dissertation, the design was performed on the city's main zone with the largest density in the Figures 1,320-1,340. In the next step, the network triangulation was conducted. Finally, the Debiw as allocated based on the triangulation conducted and considering the density of the city for year of horizon. Ultimately, the network of Marivan was designed and calibrated according to hydraulic criteria and pressure zoning. The output of this model can be used in water-supply projects, improvement and reform of the existing net-work in the city, and various other studies. Numerous and various graphs obtained in different parts of a network modelled can be used in the analysis of critical situation, leakage.

Simplified Analysis of Agricultural Water Network Model Using SWMM - A Case Study of Mandae Reservoir - (SWMM을 활용한 농업용수 네트워크 모형 단순화 분석 - 만대 저수지 사례를 중심으로 -)

  • An, Sung-Soo;Bang, Na-Kyoung;Lee, Jong-Seo;Bang, Sung-Soo;Nam, Won-Ho;Kim, Han-Joong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.27-37
    • /
    • 2022
  • This study established a water supply network based on the operation case of Mandae Reservoir in Yanggu-gun, Gangwon-do, to analyze the efficient distribution and management of agricultural water supplied from the reservoir to irrigation areas using the hydraulic analysis model SWMM. In order to construct a model to analyze the water canal network, network conditions needs to be simplified, and in particular, excessive detail or simplification of the irrigation area can lead to errors in the analysis results. Therefore, the effect of the water canal network model was analyzed by simulating the appropriate simplification process step by step. The results of simplifying the actual block shape of the analysis target area using SWMM showed that there was no significant difference in the results even if 7 lots were simplified to 2. Also, it was found that the construction and analysis of a simplified network model were reliable when the excess quantity was 2% or more compared to the required quantity for each case of analysis of the paddy field.

Evaluation of Corrosion Index by Water Quality Parameters in Korea (국내 수질에 적합한 부식성지수 선정 연구)

  • Ahn, Kyunghee;Yu, Soonju;Park, Sujeong;Kwon, Ohsang
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.4
    • /
    • pp.615-623
    • /
    • 2012
  • In this study, we evaluate the corrosion indexes (CI) such as Langelier Index (LI), Larson ratio (LR), Ryznar saturation index (RSI), Aggressiveness index (AI) of water quality for raw water, treated water and water in distribution reservoir at major eight drinking water treatment plants (DWTPs) in Korea. By analyzing secondary contamination of tap water, the variation of secondary contaminants was investigated with regard to pipe materials, aging and corrosion index (CI). In addition, we suggested an appropriate CI applicable water quality and the management plan for CI monitoriing. All CI showed corrosive water quality, and they did not change significantly in the distribution network. However, Copper (Cu), iron (Fe) and zinc (Zn) concentrations as secondary contaminants increased through the distribution network. Among CI, LI was most sensitive to changes in raw water quality and drinking water treatment. Also, it has high correlations with other indexes such as RSI, AI. Therefore, LI is considered as an appropriate CI to the domestic water quality. Based on these result, we propose LI as a drinking water quality standard to control the pipe corrosion from DWTPs.

A Study on Water Network Modeling System Based Upon GIS (지리정보시스템 기반의 상수관망 모델링 시스템 연구)

  • Kim, Joon-Hyun;Yakunina, Natalia
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.315-321
    • /
    • 2010
  • ArcView and water network models have been integrated to develop the water network modeling system based upon GIS. To develop this system, pre, main, and post processing systems are required. GIS programming technique was adopted by using the ArcView's script language Avenue. The input data of models have been prepared by using the AutoCAD Map3D through the conversion of modeling input data to GIS data for A city. The modeling has been implemented by using EPANET, WaterCAD, InfoWorks. To develop the post processing system, the modeling results of the water network models have been analyzed by using GIS. During the application process of the developed system to B city with 300,000 population, main problems were found in the constructed GIS DB of that city. Thus, pilot study area of B city has been constructed, and pre-, main, and post-processing techniques were invented based upon GIS. Finally, the problems related to waterworks GIS projects in Korea were discussed and solutions were suggested.

Development of integrated marine monitoring network on southern coastline of Caspian sea

  • Najafi-Jilani, A.;Nik-Khah, A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.3 no.2
    • /
    • pp.136-140
    • /
    • 2011
  • Monitoring of water surfaces through permanent measurement of hydrodynamic and meteorological data is one of the main requirements in safe and sustainable water management. The Caspian Sea, the major surface water body in Iran, significantly affects more than 600 km of urban and industrial coastline. In the present work, an integrated marine monitoring network for the entire southern coastline of the Caspian Sea was developed. The main design concerns centered on the network measuring components and data recording, checking, filtering, gap recognition, and transferring systems. Four coastal monitoring stations were assigned, along with two regional collecting stations and one central data station for gathering, checking and delivering recorded data at different access levels. Applicable guidelines on selection of measuring devices for both shallow and deep water zones are presented herein.

Real-time Water Monitoring System for Small Water Supply Facility using High Reliable Wireless Sensor Network (고신뢰 무선센서네트워크를 이용한 실시간 수질 모니터링 시스템)

  • Kang, Hoyong;Jang, Youn-Seon
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.331-341
    • /
    • 2015
  • In this paper, real-time water quality monitoring system of small water supply facilities based on IEEE 802.15.4e-2012 DSME MAC and IEEE 802.15.4g-2012 PHY standard is presented, which is capable to acquire for highly reliable water quality information in the wide outdoor areas for effective water quality management of small water quality facilities is distributed in the long distance and remote areas. Previously, Long distance transmission is difficult in most water quality sensor module is using RS-485 protocol. But with this system, even in harsh outdoor environment, it is possible to establish a radio wave sensor in a wide area network, and not only water quality sensor shall be connected to the wireless system, but also wireless integrated management system shall provide more effective way of management of the numerous small water supply facilities spread throughout the community, so that the administrator can remotely monitor the data of water turbidity, pH, residual chlorine in the water-supply, water-level, and generate alarm to cope with risks. The management of small water facilities is done by residents will be very effective to notice water quality information of small water facilities to residents.

Thermal Analysis of IPMSM with Water Cooling Jacket for Railway Vehicles

  • Park, Chan-Bae
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.882-887
    • /
    • 2014
  • In this paper, the water cooling method among the forced coolant cooling methods is considered to be applied to the 110kW-class IPMSM for railway vehicles. First, basic thermal property analysis of the IPMSM is conducted using the three-dimensional thermal equivalent network method. Then, based on the results of the basic thermal property analysis, some design requirements for the water cooling jacket are deduced and a basic design of the water cooling jacket is carried out. Finally, thermal equivalent circuit of the water cooling jacket is attached to the IPMSM's 3D thermal equivalent network and then, the basic thermal and effectiveness analysis are conducted for the case of applying the water cooling jacket to the IPMSM. In the future, the thermal variation trends inside the IPMSM by the application of the water cooling jacket is expected to be quickly and easily predicted even at the design step of the railway traction motor.