• Title/Summary/Keyword: Water Network

Search Result 2,033, Processing Time 0.028 seconds

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor (오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

Implementation of a Display and Analysis Program to improve the Utilization of Radar Rainfall (레이더강우 자료 활용 증진을 위한 표출 및 분석 프로그램 구현)

  • Noh, Hui-Seong
    • Journal of Digital Contents Society
    • /
    • v.19 no.7
    • /
    • pp.1333-1339
    • /
    • 2018
  • Recently, as disasters caused by weather such as heavy rains have increased, interests in forecasting weather and disasters using radars have been increasing, and related studies have also been actively performed. As the Ministry of Environment(ME) has established and operated a radar network on a national scale, utilization of radars has been emphasized. However, persons in charge and researchers, who want to use the data from radars need to understand characteristics of the radar data and are also experiencing a lot of trials and errors when converting and calibrating the radar data from Universal Format(UF) files. Hence, this study developed a Radar Display and Analysis Program(RaDAP) based on Graphic User Interface(GUI) using the Java Programming Language in order for UF-type radar data to be generated in an ASCII-formatted image file and text file. The developed program can derive desired radar rainfall data and minimize the time required to perform its analysis. Therefore, it is expected that this program will contribute to enhancing the utilization of radar data in various fields.

Electrospun Non-Directional Zinc Oxide Nanofibers as Nitrogen Monoxide Gas Sensor (전기방사법에 의해 합성된 무방향성 산화아연 나노섬유의 일산화질소 가스 감지 특성)

  • Kim, Ok-Kil;Kim, Hyojin;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.609-614
    • /
    • 2012
  • We report on the NO gas sensing properties of non-directional ZnO nanofibers synthesized using a typical electrospinning technique. These non-directional ZnO nanofibers were electrospun on an $SiO_2$/Si substrate from a solution containing poly vinyl alcohol (PVA) and zinc nitrate hexahydrate dissolved in distilled water. Calcination processing of the ZnO/PVA composite nanofibers resulted in a random network of polycrystalline ZnO nanofibers of 50 nm to 100 nm in diameter. The diameter of the nanofibers was found to depend primarily on the solution viscosity; a proper viscosity was maintained by adding PVA to fabricate uniform ZnO nanofibers. Microstructural measurements using scanning electron microscopy revealed that our synthesized ZnO nanofibers after calcination had coarser surface morphology than those before calcination, indicating that the calcination processing was sufficient to remove organic contents. From the gas sensing response measurements for various NO gas concentrations in dry air at several working temperatures, it was found that gas sensors based on electrospun ZnO nanofibers showed quite good responses, exhibiting a maximum sensitivity to NO gas in dry air at an operating temperature of $200^{\circ}C$. In particular, the non-directional electrospun ZnO nanofiber gas sensors were found to have a good NO gas detection limit of sub-ppm levels in dry air. These results illustrate that non-directional electrospun ZnO nanofibers are promising for use in low-cost, high-performance practical NO gas sensors.

Self-Assembly of Three-Dimensional Copper(II) Macrocyclic Complex with 2,5-Pyridinedicarboxylate Linked by Hydrogen Bond (수소 결합에 의한 삼차원의 Copper(II) 거대고리 착물과 2,5-Pyridinedicarboxylate와의 자기조립)

  • Ki-Young Choi;Haiil Ryu;Yong-Son Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.104-108
    • /
    • 2003
  • The reaction of $[Cu(L)]Cl_2{\cdot}H_2O(L=3,14-dimethyl-2,6,13,17-tetraazatricyclo[14,4,0^{1.18},0^{7.12}]docosane)$ with 2,5-pyridinedicarboxylate(pdc) led to the formation of $[Cu(L)(H_2O)](pdc){\cdot}6H_2O(1)$. The structure was characterized by X-ray crystallography and spectroscopic method. The coordination geometry around the copper atom is a distorted square-pyramid with four secondary amines of the macrocycle occupying the basal sites and a water molecule at the axial position. Intermolecular hydrogen bonds in 1 form a three-dimensional molecular network.

Electroanalytical Applications Based on Carbon Nanotube/Prussian Blue Screen-printable Composite

  • Shim, Jun-Ho;Lee, Jae-Seon;Cha, Geun-Sig;Nam, Hak-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1583-1588
    • /
    • 2010
  • A single step fabrication process of carbon nanotube/Prussian Blue (CNT/PB) paste electrodes based on screen printing technology has been studied as an amperometric sensor for the determination of hydrogen peroxide and free chlorine. Compared to the classical carbon paste (CP) electrode, the CNT paste electrode greatly enhanced the response in the presence of hydrogen peroxide due to the electrocatalytic activity of the CNT. Based on the CNT/binder paste, PB was also incorporated into a network of CNT paste and characterized. The best electroanalytical properties of PB-mixed sensors to hydrogen peroxide were obtained with PB ratio of 10 wt % composition, which showed fast response time ($t_{90}{\leq}5$ s; 0.2 - 0.3 mM), low detection limit of 1.0 ${\mu}M$, good linear response in the range from $5.0{\times}10^{-5}$ - $1.0{\times}10^{-3}$ mol $L^{-1}$ ($r^2$ = 0.9998), and high sensitivity of -8.21 ${\mu}AmM^{-1}$. In order to confirm the enhanced electrochemical properties of CNT/PB electrode, the sensor was further applied for the determination of chlorine in water, which exhibited a linear response behavior in the range of 50 - 2000 ppb for chlorine with a slope of 1.10 ${\mu}Appm^{-1}$ ($r^2$ = 9971).

SIMULTANEOUS OBSERVATIONS OF H2O AND SIO MASERS TOWARD KNOWN EXTRAGALACTIC WATER MASER SOURCES

  • CHO, SE-HYUNG;YOON, DONG-HWAN;KIM, JAEHEON;BYUN, DO-YOUNG;WAGNER, JAN
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.6
    • /
    • pp.357-364
    • /
    • 2015
  • We observe ten known 22GHz H2O maser galaxies during February 19-22, 2011 using the 21 m Tamna telescope of the Korean VLBI Network and a new wide-band digital spectrometer. Simultaneously we searched for 43GHz SiO v = 1, 2, J = 1-0 maser emission. We detect H2O maser emission towards five sources (M 33, NGC 1052, NGC 1068, NGC 4258, M 82), with non-detections towards the remaining sources (UGC 3193, UGC 3789, Antennae H2O-West, M 51, NGC 6323) likely due to sensitivity. Our 22GHz spectra are consistent with earlier findings. Our simultaneous 43GHz SiO maser search produced non-detections, yielding - for the first time - upper limits on the 43GHz SiO maser emission in these sources at a 3 σ sensitivity level of 0.018K-0.033K (0.24 Jy-0.44 Jy) in a 1.75 km s−1 velocity resolution. Our findings suggest that any 43GHz SiO masers in these sources (some having starburst-associated H2O kilomasers) must be faint compared to the 22GHz H2O maser emission.

DSP-Based Micro-Modem for Underwater Acoustic Communications (DSP 기반 초소형 수중 음향통신 모뎀)

  • Lee, Dongsoo;Lee, Sangmin;Park, Sung-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.275-281
    • /
    • 2014
  • Recently, the need for various underwater application systems targeting efficient resource exploration and aquatic ecosystem monitoring is rapidly increasing in littoral sea and inland waters. In this paper, we focus on the research and development of digital module of acoustic micro modem which can be used for underwater mobile communication systems and underwater sensor network systems. Specifically, a digital module of acoustic modem embedding digital signal processor is designed and implemented. On top of the developed hardware platform, physical layer frame generation and recovery and channel coding algorithms are mounted and tested in a water tank and a pond to verify its functionality and performance. According to experimental results, less than 1 percent of total computational power is consumed in the processing of frame control and convolutional code with the data rate of 1 kbps. Thus, the performance of micro modem could be improved by loading efficient baseband algorithms into the processor while maintaining the implemented hardware.

The Morphological Characteristics of Anaerobic Granular Sludge (혐기성 입상슬러지의 형태학적 특성)

  • Shin, Hang Sik;Bae, Byung Uk;Paik, Byung Cheon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.91-98
    • /
    • 1991
  • In this paper, the microscopic results of granular sludge from the two-phase UASB reactors are presented, particularly on the acidogenic phase where the distillery waste water is directly delivered. Distillery wastewater as a feed contained SS of 3.6~10.6 g/l and COD of 17.3~30.4 g/l. A 12.5 l and a 4.7 l UASB reactors were used for acidogenic and methanogenic phases, repectively. Morphological studies on the granular sludge consortia were made with both scanning and transmission electron microscopies. It was interesting enough to find the different colored and shaped granules at the acidogenic on the 90th day and at the methanogenic phase on the 120th day. The acidogenic granular sludge mainly consisted of acidogenic bacteria, such as long chains of large rods, short plump rods, and various size of cocci. Whereas the filamentous bacteria of Methanothrix spp. prevail in the methanogenic granule, with dirverse bacteria entrapped therein.

  • PDF

Hybrid ANN-based techniques in predicting cohesion of sandy-soil combined with fiber

  • Armaghani, Danial Jahed;Mirzaei, Fatemeh;Shariati, Mahdi;Trung, Nguyen Thoi;Shariati, Morteza;Trnavac, Dragana
    • Geomechanics and Engineering
    • /
    • v.20 no.3
    • /
    • pp.191-205
    • /
    • 2020
  • Soil shear strength parameters play a remarkable role in designing geotechnical structures such as retaining wall and dam. This study puts an effort to propose two accurate and practical predictive models of soil shear strength parameters via hybrid artificial neural network (ANN)-based models namely genetic algorithm (GA)-ANN and particle swarm optimization (PSO)-ANN. To reach the aim of this study, a series of consolidated undrained Triaxial tests were conducted to survey inherent strength increase due to addition of polypropylene fibers to sandy soil. Fiber material with different lengths and percentages were considered to be mixed with sandy soil to evaluate cohesion (as one of shear strength parameter) values. The obtained results from laboratory tests showed that fiber percentage, fiber length, deviator stress and pore water pressure have a significant impact on cohesion values and due to that, these parameters were selected as model inputs. Many GA-ANN and PSO-ANN models were constructed based on the most effective parameters of these models. Based on the simulation results and the computed indices' values, it is observed that the developed GA-ANN model with training and testing coefficient of determination values of 0.957 and 0.950, respectively, performs better than the proposed PSO-ANN model giving coefficient of determination values of 0.938 and 0.943 for training and testing sets, respectively. Therefore, GA-ANN can provide a new applicable model to effectively predict cohesion of fiber-reinforced sandy soil.