• Title/Summary/Keyword: Water Level Monitoring

Search Result 648, Processing Time 0.037 seconds

Suppression Design of Smart Room Garden·Aquaculture System using PIC (스마트 Aquaponix 시스템 설계)

  • Choi, Yang-il;Kim, Byeong-Jun;Jeong, Hui-Tae;Shin, Kyoo-Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.350-352
    • /
    • 2018
  • In this paper, we propose a smart indoor garden aquaculture system using PIC. In the proposed smart indoor garden aquaculture system, the aquaphonics system circulates the nutrient solution of the aquarium, the filtrate tank, and the flowerpot. The automated control system that controls the state of the nutrient solution through the various sensors and controls the pump and valve is designed. As a result of the verification of the smart indoor garden aquaculture system proposed in this paper, it was confirmed that the environment suitable for the survival of fish and plants was maintained by monitoring water temperature, DO, pH measured in real time. The water level in aquarium and flower pot was controlled through automatic operation of the Electric vale and pump.

Post-disturbance Recovery Pattern in the Soft Corals-Macroalgae Mixed Habitat in Jeju Island, Korea

  • Kim, Junsu;Hong, Seokwoo;Yang, Kwon Mo;Macias, Daniela;Kim, Jeong Ha
    • Journal of Marine Life Science
    • /
    • v.6 no.2
    • /
    • pp.117-123
    • /
    • 2021
  • Post-disturbance recovery pattern of subtidal soft corals-macroalgae mixed community and the role of water depth were investigated. The experiment was conducted in a subtidal rock wall of Munseom, Jeju Island, Korea for 2.5 years. Artificial disturbance was done at established treatment plots at depths of 10, 15 and 20 m and were then compared with undisturbed control plots. After disturbance, recovery of soft corals was very slow, whereas macroalgae quickly occupied the plots and reached a similar level as the control in 6 months, and this pattern was consistent at all water depths. This unbalanced speed of recovery caused higher macroalgae establishment than soft corals in treatment compared to control plots, indicating a possible phase shift in the community structure. This study provides an important implication for the necessity of monitoring the influence of disturbance at a larger scale, from a conservation perspective of soft corals in Jeju coast.

Characteristics of Level of Perchlorate Pollution near Military Facility Areas (군사시설물 인근지역에서의 퍼클로레이트 오염수준 및 특성)

  • Choi, Jinsu;Um, Chul Yong;Chu, Kyoung Hoon;Ham, Seok Heon;Lee, Jong Hyeok;Yoo, Sung Soo;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.460-466
    • /
    • 2012
  • Perchlorate is used in a number of applications as an oxidizer in solid propellants, munitions and fireworks and is one of the endocrine disrupting chemicals, which interferes with iodide uptake into the thyroid gland. The purpose of this study was to investigate perchlorate occurrence and distribution with a results of analysis of 94 samples collected from military facilities in Korea from October 11 to October 23, 2011. Overall, among all of the 94 samples analyzed, perchlorate was detected in 6.4% of the total number of samples above $4{\mu}g/L$ (minimum reported limit) and the average concentration was $26.1{\mu}g/L$ and the maximum concentration was $107.7{\mu}g/L$ which was observed in surface water near manufacturing site of ammunition. By site classification, perchlorate was detected at one site in 4 manufacturing sites of ammunition and the maximum concentration was $107.7{\mu}g/L$ which was six times higher than that in guideline for perchlorate in Nakdong River and resulted from point source discharge. Perchlorate was detected at 3 sites in 78 measurements for shooting area and the maximum concentration was $12.4{\mu}g/L$ which was collected in dringking water and perchlorate in another sample was detected above MRL in shooting area was collected right away after shooting. These results showed that long term monitoring was needed considering weather conditions and shooting schedules.

A Study on the Evaluation of Pollution Characteristics of Sincheon Stream and Its Tributaries in Gyeonggi-do Province (경기도 신천 및 유입지천의 오염특성 평가)

  • Son, Yeong-Geum;Im, Heung-Bin;Lee, Kang-Hyuck;Kim, Jin-Guil;Im, Yun-Jung;Choi, Jeong-In;Lee, Ho-Jung;Oh, Jo-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.5
    • /
    • pp.422-430
    • /
    • 2017
  • he objective of this study is to evaluate and analyze Sincheon basin water environment system. The data were collected from 2010 August to 2016 December including BOD, SS, T-N, T-P. The results were as followed. As the result of comparing the amount of BOD generated by pollution sources in the Sincheon water system, industrial was the highest at 33,259.4 kg/day. In comparison with the tributary, it was estimated that Dong-Du water system reveals the highest level of BOD in the industry. Population and livestock was high in CheongDam and Sang-Pae water system. With the inflow stream of Hyo-Chon, Suk-Woo and Sang-Pae, the pollution degree of BOD and T-N level of Sincheon increased and pollution degree of tributary was higher than that of Sincheon's main stream. The main reason of pollutant of Suk-Woo was from untreated wastewater, and it influenced downstream of Suk-Woo. Hyo-Chon stream satisfy the water quality standard, but Zn was designated as a Monitoring contaminants, was high as 14.670 mg/L (standard 0.02~2.45mg/L)because of textile wastewater. And Sang-Pae stream was polluted by livestock wastewater of livestock farms as a nonpoint source.

The Development of the Data Error Inspection Algorithm for the Remote Sensing by Wireless Communication (원격계측을 위한 무선 통신 에러 검사 알고리즘 개발)

  • 김희식;김영일;설대연;남철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.993-997
    • /
    • 2004
  • A data error inspection algorithm for wireless digital data communication was developed. Original data converted By wireless digital data error inspection algorithm. Wireless digital data is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error inspection algorithm in order to decrease the data distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error inspection algorithm for error check of transmission data. This study is also that investigation and search for error inspection algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro processing the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which is open to public touse free within the limited power.

  • PDF

Monitoring Technology for Flood Forecasting in Urban Area (도시하천방재를 위한 지능형 모니터링에 관한 연구)

  • Kim, Hyung-Woo;Lee, Bum-Gyo
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.405-408
    • /
    • 2008
  • Up to now, a lot of houses, roads and other urban facilities have been damaged by natural disasters such as flash floods and landslides. It is reported that the size and frequency of disasters are growing greatly due to global warming. In order to mitigate such disaster, flood forecasting and alerting systems have been developed for the Han river, Geum river, Nak-dong river and Young-san river. These systems, however, do not help small municipal departments cope with the threat of flood. In this study, a real-time urban flood forecasting service (U-FFS) is developed for ubiquitous computing city which includes small river basins. A test bed is deployed at Tan-cheon in Gyeonggido to verify U-FFS. It is found that U-FFS can forecast the water level of outlet of river basin and provide real-time data through internet during heavy rain. Furthermore, it is expected that U-FFS presented in this study can be applied to ubiquitous computing city (u-City) and/or other cities which have suffered from flood damage for a long time.

  • PDF

Effect of Rock Mass Properties on Coupled Thermo-Hydro-Mechanical Responses at Near-Field Rock Mass in a Heater Test - A Benchmark Sensitivity Study of the Kamaishi Mine Experiment in Japan

  • Hwajung Yoo;Jeonghwan Yoon;Ki-Bok Min
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.23-41
    • /
    • 2023
  • Coupled thermo-hydraulic-mechanical (THM) processes are essential for the long-term performance of deep geological disposal of high-level radioactive waste. In this study, a numerical sensitivity analysis was performed to analyze the effect of rock properties on THM responses after the execution of the heater test at the Kamaishi mine in Japan. The TOUGH-FLAC simulator was applied for the numerical simulation assuming a continuum model for coupled THM analysis. The rock properties included in the sensitivity study were the Young's modulus, permeability, thermal conductivity, and thermal expansion coefficients of crystalline rock, rock salt, and clay. The responses, i.e., temperature, water content, displacement, and stress, were measured at monitoring points in the buffer and near-field rock mass during the simulations. The thermal conductivity had an overarching impact on THM responses. The influence of Young's modulus was evident in the mechanical behavior, whereas that of permeability was noticed through the change in the temperature and water content. The difference in the THM responses of the three rock type models implies the importance of the appropriate characterization of rock mass properties with regard to the performance assessment of the deep geological disposal of high-level radioactive waste.

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

Research on Advanced Measures for Emergency Response to Water Accidents based on Big-Data (빅데이터 기반 수도사고 위기대응 고도화 방안에 관한 연구)

  • Kim, Ho-sung;Kim, Jong-rip;Kim, Jae-jong;Yoon, Young-min;Kim, Dae-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.317-321
    • /
    • 2022
  • In response to Incheon tap water accident in 2019, the Ministry of Environment has created the "Comprehensive Measures for Water Safety Management" to improve water operation management, provide systematic technical support, and respond to accidents. Accordingly, K-water is making a smart water supply management system for the entire process of tap water. In order to advance the response to water accidents, it is essential to secure the reliability of real-time water operation data such as flow rate, pressure, and water level, and to develop and apply a warning algorithm in advance using big data analysis techniques. In this paper, various statistical techniques are applied using water supply operation data (flow, pressure, water level, etc) to prepare the foundation for the selection of the optimal operating range and advancement of the monitoring and alarm system. In addition, the arrival time is analyzed through cross-correlation analysis of changes in raw water turbidity between the water intake and water treatment plants. The purpose of this paper is to study the model that predicts the raw water turbidity of a water treatment plant by applying raw water turbidity data considering the time delay according to the flow rate change.

  • PDF

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.