• Title/Summary/Keyword: Water Level Monitoring

Search Result 648, Processing Time 0.031 seconds

Parametric and Non-parametric Trend Analyses for Water Levels of Groundwater Monitoring Wells in Jeju Island (제주도 지하수 관측망 수위에 대한 모수 및 비모수 변동경향 분석)

  • Choi, Hyun-Mi;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.5
    • /
    • pp.41-50
    • /
    • 2009
  • Water levels in groundwater monitoring wells of Jeju Island were analyzed using parametric and non-parametric trend analyses. Number of used monitoring wells in the analysis are 94 among totally 106 monitoring wells and the monitoring period is greater than single year, from 2001 to 2009. For the trend analysis, both parametric (linear regression) and nonparametric (Mann-Kendall trend test and Sen's trend test) methods were adopted. Results of the linear regression analysis on daily basis indicated that about 58.5% of the monitoring wells showed a decreasing trend, and analysis using monthly median indicated that about 79.8% showed a decreasing trend. The Mann-Kendall trend test and Sen's trend test with monthly median values in confidence levels of 95% and 99% showed the same analysis results. In confidence level of 95%, 32% were decreased, 3% were increased and the remains showed no trend. However, in confidence level of 99%, 16% were decreased, 2% were increased and the remains showed no trend. The largest decline rates of water levels were detected mainly at the coast of the northwestern and southwestern parts, which is expected to closely related to the increased pumping in the urban area and tourist resort.

Implementation of Human Positioning Monitoring Device for Underwater Safety (수중안전을 위한 인체 위치추적 모니터링 장치 구현)

  • Jong-Hwa Yoon;Dal-Hwan Yoon
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.225-233
    • /
    • 2023
  • This paper implements a system that monitors human body lifting information in the event of a marine accident. The monitoring system performs ultrasonic communication through a lifting device controller that transmits underwater environment information, and LoRa communication is performed on the water to provide GPS information within 10 km to the control center or mother ship. The underwater lifting controller transmits pneumatic sensor, gyro sensor, and temperature sensor information. In an environment where the underwater conditions increase by one atmosphere of water pressure every 10m in depth, and the amount of air in the instrument decreases by half compared to land, a model of a 60kg underwater mannequin is used. Using one 38g CO2 cartridge in the lifting appliance SMB(Surface Maker Buoy), carry out a lifting appliance discharge test based on the water level rise conditions within 10 sec. Underwater communication constitutes a data transmission environment using a 2,400-bps ultrasonic sensor from a depth of 40m to 100m. The monitoring signal aims to ensure the safety and safe human structure of the salvage worker by providing water depth, water temperature, and directional angle to rescue workers on the surface of the water.

Behavior of Fill Dam Subjected to Continuous Water Level Change and Overflow (지속적 수위변동 및 월류에 따른 저수지 제체의 거동 연구)

  • Lee, Chungwon;Maeng, Youngsu;Kim, Yongseong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.6
    • /
    • pp.41-48
    • /
    • 2014
  • In this study, the behavior of fill dam with continuous water level change considering velocity changes via centrifugal model test was investigated. In addition, the collapse of fill dam due to the overflow was also experimentally simulated. The experimental results demonstrate that the pore water pressures and displacements vary in proportion to the water-level-change velocity, and the displacement increment is independent to the water-level-change velocity. Also, it is confirmed that the continuous water level change induces to the progress of fill-dam deformation due to displacement accumulation and the fill-dam stability dramatically degrades owing to the overflow. Hence, the real-time monitoring of pore water pressures and displacements of fill dam, and the control of water level in heavy rain through the countermeasure such as opening sluice gates are needed to ensure the stability of fill dam.

Efficiency Study of Measurement Method by Flow Duration (유황별 유속측정 방법에 따른 유효성 연구)

  • Ham, Sang In;Lee, Jeong Hwan;Kim, Dae Young;Ha, Don Woo;Kim, Yoon Soo;Jung, Kang-Young;Lee, Yeong Jae;Kim, Gyeong Hyeon;Kim, Young Suk
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.462-469
    • /
    • 2018
  • There are differences in method and cycle of flow rate survey depending on purpose of the operating department. To verify and use results of flow data according to the purpose, flow data of the directly measured and tele monitoring system were compared to verify validity. Flow measurement in the Ministry of Environment is aimed at setting up a standard flow of target water quality for water quality management and securing flow data of low and normal water level seasons for water quality evaluation. In this study, correlation analysis result ($R^2$) of same time zone data by direct measurement and tele monitoring system (TMS) at Seombon D point, a unit watershed of Seomjin river, for six years ('10 ~ '15) according to implementation of Total Daily Maximum Load (TDML) was wading 0.716, boating 0.962 and on bridge 0.943, and effectiveness of measurement method was verified by characteristics of flow duration as a season of dry and low-water; normal and high water are appropriate for wading, boating, and on bridge respectively. Results revealed it is reasonable to use directly measured results using the wading and boating method for low water level and dry seasons, and TMS data for rainy seasons. It can be used important data for future policy decisions.

Propagation Environment Analysis and Wireless Mesh Network Implementation for monitoring the Four Rivers (based on Hapcheon weir) (4대강 주변 하천모니터링을 위한 무선 메쉬 네트워크 전파환경 분석 및 구축(합천보 중심으로))

  • Hong, Sung-Taek;Jin, Ryeok-Min
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.127-134
    • /
    • 2012
  • Four river project in the South Korea contributes to solve flood damages and water shortages. Also, it has purpose for creating water ecosystem and improving the level of people' cultural leisure and quality of life through inducing water quality improvement and river restoration. It is necessary to monitor a variety of observing data in river areas among dozens to hundreds of kilometer for safe river administration. The 20th construction area of the four river project is located on Hapcheon areas, where wireless mesh network was installed to manage the basin. In the process of network construction, the characteristic of surrounding areas is considered about embodying secure service by investing the least expense. Besides, transmission environment analysis is performed such as LOS tests and reception level analysis, and transmission speed measurement to create safe service. Reception level in all places is confirmed among -55 dBm ~ -70 dBm, and data transmission speed proves more than 20 Mbps.

Characteristics of Water Levels and Occurrences of Thermal Groundwater at the Yuseong Spa Area (유성지구 지열수자원의 산출 및 수위변동 특성)

  • Moon, Sang-Ho;Ha, Kyoo-Chul;Kim, Yung-Sik;Cho, Sung-Hyeon
    • Economic and Environmental Geology
    • /
    • v.39 no.5 s.180
    • /
    • pp.537-554
    • /
    • 2006
  • Water levels of thermal groundwater ($>30^{\circ}C$) were recorded from March 2002 to June 2006 at several monitoring wells within the Yuseong spa area. Using these data, we elucidated the long-term cyclic fluctuations of thermal groundwater levels with 1 year period. We also observed a noticeable water level variation with periods of 0.5, 1 and 7 days in most monitoring wells, which indicates relatively good hydraulic connectivity within the main hotspring area. By comparing water level variations among several wells, we found out that E-W and N-S trending geological structures should be an important control factor for emplacement and flow of thermal groundwater in the study area. It may be also inferred that geothermal source is highly associated with the hydraulic connectivity of aquifers at the Yuseong spa area.

Monitoring of Outlet Discharge and Water Quality from a Small Agricultural Reservoir (소규모 농업용 저수지의 통관 방류량 및 수질 측정)

  • Choi, Jin-Kyu;Son, Jae-Gwon;Koo, Ja-Woong;Yoon, Kwang-Sik;Kim, Young-Ju
    • Journal of Korean Society of Rural Planning
    • /
    • v.6 no.2 s.12
    • /
    • pp.73-81
    • /
    • 2000
  • This study was carried out to measure the amount of outlet discharge and analyse the water quality from an agricultural reservoir. Joongpyong reservoir was selected as the monitoring site. Daily discharge was determined by measured water level data of delivery canal and the stage-discharge relation curve. The measured water discharge through culvert outlet of Joongpyong reservoir was 593,200m3 which was equivalent to irrigation depth 1,186mm during irrigation period in 1999. And water samples were taken from the surface water of reservoir and delivery canal, periodically. Temporal variation of water quality constituents such as water temperature, pH, EC, total nitrogen, total phosphorus were investigated. The result showed that pH was ranged 6.9 7.8, total nitrogen 1.39 4.11mg/L, total phosphorus 0.007 0.036 mg/L, respectively.

  • PDF

A Study on the Constitution and the Application of FIA System for Measurement of Nitrite (The Field Water Samples at Kwangju) (아질산성질소 축정용 FIA의 제작 및 용용에 관한 연구 (광주광역시 광주천 시료를 대상으로))

  • Rhee, J.S.;Park, W.C.;Lee, S.W.;Kim, Y.J.
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.283-290
    • /
    • 2002
  • In this study, home-made detection system by means of noble FIA is introduced on the measurement of toxic nitrite in the water samples collected from the area of Kwangju. As the standard calibration between 30 to 1000 ppb, the linearity has been shown more than 0.9999 as the correlation coefficient($R^2$) with the detection limit 1.5 ppb(S/N>2). The distribution of sample concentration was monitored as N.D. - 123 ppb which is wide span of concentrations in field water samples. The low level of nitrite is hardly detectable with other expensive sophisticated instruments including ion chromatography. Whereas the result of high concentration brings forth the necessity monitoring constantly our precious water resources. Successfully, the FIA system has played a very important role detecting wide span of nitrite in water sample. This technique can be adopted for controlling our environment in the near future.

제주도 동부해안 한동리지역의 수문지질학적 연구

  • 김기표;윤정수;박원배
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.9-12
    • /
    • 2002
  • The purpose of this study is to understand the high saline water phenomenon of Handong-ri area in the eastern coast of Jeju Island, were investigate the tidal effect of groundwater level, variation of electric conductivity and temperature, geological logging on the monitoring wells, chemical water quality, and ratios of oxygen istope of groundwater and seawater Results in investigating variation of interface zone of freshwater and saline water represented that the hyaloclastites formed at below groundwater table is developing toward the coast; this area consisted of stratum of good permeability. Hyaloclastites is presumed the main path of the high salinity water There are a lot of movement by the tide at upper layer. Salinity of lower layer spreads to upper up step in proportion to tidal energy. Because of hydrogeological characteristics, Interface zone of freshwater and saline water is made, High salinity of groundwater occur in east coastal area of Jeju Island. Therefore, I think that high saline groundwater phenomenon is natural condition by simple mixing.

  • PDF

USN-based Water Treatment Plant Facilities Data Management Techniques and Reliability (USN 기반 수직형 정수처리시설 데이터 최적관리 및 신뢰성 검증연구)

  • Jang, Sang-Bok;Shin, Gang-Wook;Hong, Sung-Taek;Lee, An-Kyu;Park, Hye-Mi;Chun, Myung-Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2736-2744
    • /
    • 2013
  • In this paper, we present a Smart Water Treatment Plant using Zigbee USN devices and a real-time monitoring system in K-water Flow Meter Calibration Center Building. For verification, the data of vertical type WTP such as flow rate, pressure, water level and water temperature are obtained by the Zigbee USN devices, operating in 2.45 GHz band, and be wirelessly surveilled by the real-time monitoring system. The received data from the sensor is transmitted to the data processing device, and then the processed data can be monitored on a smart phone. Consequently, the pilot plant based on the low-cost and high-efficiency USN has been developed with the performance analysis for the communication network and remote monitoring system on mobile devices.