하수관거 정비지역의 관거이송 유량 및 수질특성 변화 (Changes in Characteristics of Sewer Flow & Its Water Quality from the Sewer Rehabilitation Area)

  • 박준대;오승영;최윤호;김용석
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.196-208
    • /
    • 2015
  • This study analyzed the characteristics of sewer flow and its water quality, and investigated changes in the characteristics in three areas where the sewer rehabilitation projects have been carried out. In S1 area, the patterns of the flow became regular and the range of the fluctuation decreased after the sewer rehabilitation. The flow and its BOD concentration increased. The infiltration/inflow and exfiltration showed clear distinction before and after the sewer rehabilitation in this area. In S2 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased considerably after the sewer rehabilitation. Big decrement in stormwater inflow but small in exfiltration appeared in this area. In S3 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased in a small rate in this area.

상수도관망에서 대수용가의 유량변화에 따른 수압 및 탁도발생 영향평가 (Impact assessment for water pressure and turbidity occurrence by changes in water flow rate of large consumer at water distribution networks)

  • 최두용;김주환;최민아;김도환
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.277-286
    • /
    • 2014
  • Water discolouration and increased turbidity in the local water service distribution network occurred from hydraulic incidents such as drastic changes of flow and pressure at large consumer. Hydraulic incidents impose extra shear stresses on sediment layers in the network, leading to particle resuspension. Therefore, real time measuring instruments were installed for monitoring the variation of water flow, pressure, turbidity and particulates on a hydrant in front of the inlet point of large apartment complex. In this study, it is attempted to establish a more stable water supply plan and to reduce complaints from customers about water quality in a district metering area. To reduce red or black water, the water flow monitoring and control systems are desperately needed in the point of the larger consumers.

수질오염총량관리 목표수질 초과지역에 대한 유황별 초과기여도 분석 (Contributions to the Impaired Water Bodies by Hydrologic Conditions for the Management of Total Maximum Daily Loads)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.574-581
    • /
    • 2012
  • It is important to analyze the status of water quality with relation to the stream flow to attain water quality goal more effectively in the unit watersheds for the management of Total Maximum Daily Loads (TMDLs). This study developed a flow duration-water quality distribution graph to figure out water quality appearances on the flow variation and analyzed contributions of water quality observations to the impaired water bodies quantitatively by hydrologic conditions. Factors relating to water quality variation can be analyzed more precisely and assessed on the base of quantified contributions. It is considered that this approach could be utilized to establish a more effective plan for the water quality improvement including the prioritization of pollution reduction options.

수압을 받는 콘크리트에서의 수분 이동에 관한 실험적 연구 (Experimental Study on the Water Penetration of Concrete with Water Pressure)

  • 유조형;이한승;강인석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.573-576
    • /
    • 2006
  • The objective of the study is to investigate the depth of penetration of concrete water forced in under pressure. For this purpose, the experiments for the depth of penetration by selecting the factors and levels such as water pressure, pressure time were executed. The flow of water of concrete examined theoretically and experimentally. As a result, It is found that in the case of low water pressure approximately 0.15Mpa or less, the flow is Darcy seepage flow, the same as flow in an ordinary sand stratum, whereas in the case of high water pressure, the flow is diffused seepage flow accompanied by internal deformation of concrete.

  • PDF

유량 데이터 오차율 분석을 통한 최적의 유량데이터 취득방안 제안 (The Propose of Optimal Flow Data Acquisition by Error Rate Analysis of Flow Data)

  • 김윤하;최현주
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.249-256
    • /
    • 2017
  • Recently, application areas based on M2M (Machine-to-Machine communications) and IoT (Internet of Things) technologies are expanding rapidly. Accordingly, water flow and water quality management improvements are being pursued by applying this technology to water and sewage facilities. Especially, water management will collect and store accurate data based on various ICT technologies, and then will expand its service range to remote meter-reading service using smart metering system. For this, the error in flow rate data transmitting should be minimized to obtain credibility on related additional service system such as real time water flow rate analysis and billing. In this study, we have identified the structural problems in transmitting process and protocol to minimize errors in flow rate data transmission and its handling process which is essential to water supply pipeline management. The result confirmed that data acquisition via communication system is better than via analogue current values and pulse, and for communication method case, applying the industrial standard protocol is better for minimizing errors during data acquisition versus applying user assigned method.

수질오염총량관리 합류식지역의 우기시 관거이송 변화유형 (Patterns on Sewer Transfer Flow for Rain Weather Period in the Area with Combined Sewer System for the Management of TMDLs)

  • 박준대;오승영;김지태
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.1008-1015
    • /
    • 2010
  • Discharged pollution load is varied as rainfall changes in the area with combined sewer system. Changes in discharged pollution load are directly related with those of sewer transfer flow. Therefore, it is important to identify the pattern of sewer transfer flow for the analysis of changes in discharged pollution load. This study reviewed the type of distribution of sewer transfer flow for 17 sewage treatment plants and developed simple formular to estimate sewer transfer flow as rainfall changes. 11 facilities showed to have some relation with rainfall in the change of sewer transfer flow but 6 facilities to have no relation. Relationships between rainfall amount and sewer transfer flow showed that 6 facilities out of 11 had relatively strong relationships above R2=0.5, which were considered to be affected directly by rainfall changes. The formular which explain the relationship between rainfall and sewer transfer flow can be applied in the analysis of rainfall effects on discharged pollution load, therefore, the more appropriate evaluation will be done.

지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가 (A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump)

  • 정영주;조재훈;김용식;조영흠
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.

국내 중소하천에 설치된 아이스하버 어도 내부 흐름 특성 규명 (Investigation for flow characteristics of ice-harbor type fishway installed at mid-sized streams in Korea)

  • 백경오;민병조
    • 한국수자원학회논문집
    • /
    • 제55권1호
    • /
    • pp.33-42
    • /
    • 2022
  • 본 연구에서는 3차원 상용 수치모형 Flow-3D를 활용하여 상류 수위(유입유량) 변동, 격벽의 간격(pool의 길이) 변화, 잠공 유무 등에 따른 아이스 하버 어도 내 흐름 양상을 분석하였다. 수치모의 결과의 적합성을 입증하기 위해 경안천 대곡교 하류에 설치된 실제 어도에서 3차원 초음파 유속계를 사용하여 어도 출구부 단면 유속과 유량을 관측하였다. Flow-3D 모형에는 난류 모듈로 4가지를 선택할 수 있는데, 관측 자료로 검증 결과 RNG 모형이 아이스하버 어도 내 흐름 특성을 가장 잘 재현하였다. 하천의 유량 전량이 어도로만 유입되어 흐른다는 조건에서 수위 변화에 따른 어도 내 유속구조를 모의해 보았다. 그 결과 최저수위에서는 잠입류와 표면류가 혼재하여 발생하였는데, 최저수위에서 약 10 cm 이상만 수위가 상승하여도 모든 pool에서 잠입류가 사라지고 오직 표면류만 발생하였다. 예상과 달리 수위가 조금 상승해도 흐름이 꽤 단순하게 표면류 위주로 발생하였다. 격벽간 간격을 늘려주면 수위가 상승하더라도 잠입류와 표면류가 혼재되어 나타나는 현상이 지속되었다. 그리고 격벽 하단에 잠공이 있는 경우가 없는 경우에 비해 잠입류가 여러 pool에서 생성되는 경향을 보였다. 보다 적극적인 어도 사후 관리로 잠공 폐색을 막아 어도 내 다양한 흐름이 생성될 수 있도록 유도하는 것이 필요해 보인다.

DEM을 기반으로 한 흐름방향 모의기법에 따른 배수구조의 변동성 해석 (Analysis of Variation for Drainage Structure with Flow Direction Methods on the Basis of DEM)

  • 박혜숙;김주철
    • 한국물환경학회지
    • /
    • 제34권4호
    • /
    • pp.391-398
    • /
    • 2018
  • The main purpose of this study is to suggest and recommend the more reliable flow direction methods within the framework of DEM and power law distribution, by investigating the existing methodologies. To this end SFD (single flow direction method), MFD (multiple flow direction method) and IFD (Infinite flow direction method) are applied to analyze the determination of a flow direction for the water particles as seen in the Jeonjeokbigyo basin, and then assessed with respect to the variation of flow accumulation in that region. As the main results revealed, the study showed the different patterns of flow accumulation are found out from each applications of flow direction methods utilized in this study. This brings us to understand that as the flow dispersion on DEM increases, in this case the contributing areas to the outlet grow in sequence of SFD, IFD, MFD, but it is noted that the contribution of individual pixels into outlet decreases at that time. In what follows, especially with the MFD and IFD, the result tends to make additional hydrologic abstraction from rainfall excess, as noted due to the flow dispersion within flow paths on DEM. Based on the parameter estimation for a power law distribution, which is frequently used for identify the aggregation structure of complex system, by maximum likelihood flow accumulation can be thought of as a scale invariance factor. In this regard, the combination of flow direction methods could give rise to the more realistic water flow on DEM, as revealed through the separate flow direction methods as utilized for dispersion and aggregation effects of water flow within the available different topographies.