• Title/Summary/Keyword: Water Evaporation

Search Result 963, Processing Time 0.024 seconds

Evaporation Cooling of Water Droplet on Aluminum with Various Surface Roughness and Droplet Diameter in Conductive Condition (전도조건 하에서 표면조도와 액적 직경의 변화에 따른 알루미늄의 액적 증발 냉각)

  • Jang, C.S.;Choi, W.S.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.18 no.6
    • /
    • pp.375-382
    • /
    • 2005
  • This paper presents the results of experimental investigation for the effect of heat conduction on the evaporation cooling of water droplet in the process of heat treatment. The experiments are mainly focused on the surface temperature, the surface roughness and the droplet diameter at aluminum. The range of surface temperature is from $80^{\circ}C$ to $140^{\circ}C$, surface roughness is from $R_a=0.18{\mu}m$ to $R_a=1.36{\mu}m$ and droplet diameter is from 2.4 mm to 3.0 mm. The results show that the total evaporation time is shorter for the larger surface roughness, the time averaged heat flux has maximum value for the larger surface roughness and exist the critical heat flux. The total evaporation time has a big influence on the evaporation region for the smaller droplet size, but the total evaporation time has not influence on the nuclear boiling region.

Evaporation Theory for Reclaimed Clay (준설 점토 지반에서의 증발 이론 개발)

  • 이형주;이인모;이영남;성상규
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.55-64
    • /
    • 2003
  • Desiccation of a soil is basically the removal of water by evaporation, which is controlled by evaporativity and evaporability. Surface evaporation improves the trafficability which is essential for the access of construction equipment in the area reclaimed with soft clay. The existing traditional methods for evaluating evaporation can not account for the deformation of reclaimed soft soils during evaporation. Therefore, a theoretical model for predicting the rate of evaporation from the surface of a deformable material is proposed. The model is based on a system of equations for coupled heat and mass transfer in unsaturated soils. The modified pressure plate extractor test and glass desiccator test were carried out to obtain the soil-water characteristic curve for a deformable soil. The column drying test was conducted to investigate one dimensional water flow, heat flow and evaporation in the surface. A finite difference program was developed to solve the coupled nonlinear partial differential equations, which permit the study of water, vapor and heat flows in the deformable soil. Comparison between measured and simulated values shows a reasonably good matching between the two.

The Effect of Geometrical Structure on the Moisture Transport Properties of Nonwoven Batting Materials (부직포 충전재의 구조적 특성이 수분전달 특성에 미치는 영향-단층구조와 이층구조 부직포의 비교-)

  • 김희숙;나미희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.6
    • /
    • pp.810-818
    • /
    • 2000
  • The purpose of this study was to analyze the effect of geometrical structure on the moisture transport properties of nonwoven batting materials. Two types of nonwovens were used such as single and double layered nonwovens. Steady and dynamic state water vapor transport properties were measured by absorption, evaporation and cobaltous chloride method respectively. The results of this study were as follows: 1) Geometrical structure affected water vapor evaporation, but there were no differences between single and double layered nonwovens in moisture absorption. Thickness and air permeability were influencing factor on water vapor transport rate. 2) Directionality of double layered nonwoven was observed both in steady and dynamic state moisture transport. There were differences between upper and lower layer of double layered nonwoven both in moisture absorption rate and color change by cobaltous chloride method. 3) In dynamic state of water vapor transport rate, single layered nonwoven reached more rapidly at the established relative humidity. It was confirmed that geometrical structure affected water vapor evaporation and hydrophilicity of fiber affected moisture absorption because there were much more water vapor transport rate by evaporation than absorption within the same period of time.

  • PDF

Liquid Conservation Concept In The Water Evaporation Phenomenon According To The Age and Task-Situations (연령과 과제상황에 따른 물의 증발현상에 대한 아동의 액체보존개념)

  • Kim, Eun-Young
    • Korean Journal of Human Ecology
    • /
    • v.22 no.1
    • /
    • pp.17-27
    • /
    • 2013
  • The purpose of this study is to investigate children's liquid conservation concept according to their ages and task-situations in the water evaporation phenomenon. Thirty from each 4-, 6- and 8-year-old age groups (total of 90 subjects) were selected for this study. The subjects were recruited from two day-care centers, a kindergarten, and an elementary school, in Seoul. Statistical methods used for data analysis were frequencies, percentiles, means, standard deviations and repeated measures ANOVA. As a result, there was a significant difference in children's liquid conservation concept in the evaporation of water according to their ages and task-situations. 8-year-old children showed levels of cognition than 4- and 6-year-olds. Children showed higher levels of cognition in the task of drying than in the task of water level changes.

Numerical Analysis on Removal Efficiency of Water Droplets in a Curved Vane Mist Eliminator with Consideration of Evaporation and Condensation at Surface of Droplets (액적 표면에서 증발 및 응축을 고려한 곡면 형상 액적 제거장치의 제거 효율에 대한 수치 해석)

  • Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.135-143
    • /
    • 2016
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For accurate understanding of removal process in a curved vane mist eliminator, a numerical model including turbulent dispersion, evaporation and condensation of water vapor at surface of droplets is required. A two-stage curved vane mist eliminator has been modeled, and fluid flow of mixture of air and water vapor and droplet trajectories were solved simultaneously with taking into account two-way coupling. Removal efficiency of droplets with various inlet condition of relative humidities (RH, 40%, 90%, and 100%) were compared. As RH increased, the effect of evaporation decreased and inertial separation efficiencies of droplets obtained increased especially for droplets of diameter below 10 micrometers.

Geometry Effects of Capillary on the Evaporation from the Meniscus (모세관 단면 형상에 따른 계면 및 증발 특성)

  • Choi, Choong-Hyo;Jin, Songwan;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.313-319
    • /
    • 2007
  • The effect of capillary cross-section geometry on evaporation is investigated in terms of the meniscus shape, evaporation rate and evaporation-induced flow for circular, square and rectangular cross-sectional capillaries. The shapes of water and ethanol menisci are not much different from each other in square and rectangular capillaries even though the surface tension of water is much larger than that of ethanol. On the other hand, the shapes of water and ethanol menisci are very different from each other in circular capillary. The averaged evaporation fluxes in circular and rectangular capillaries are measured by tracking the meniscus position. At a given position, the averaged evaporation flux in rectangular capillaries is much larger than that in circular capillary with comparable hydraulic diameter. The flow near the evaporating meniscus is also measured using micro-PIV, so that the rotating vortex motion is observed near the evaporating ethanol and methanol menisci except for the case of methanol meniscus in rectangular capillary. This difference is considered to be due to the existence of corner menisci at the four comers.

EVAPORATION DATA STOCHASTIC GENERATION FOR KING FAHAD DAM LAKE IN BISHAH, SAUDI ARABIA

  • Abdulmohsen A. Al-Shaikh
    • Water Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.209-218
    • /
    • 2001
  • Generation of evaporation data generally assists in planning, operation, and management of reservoirs and other water works. Annual and monthly evaporation series were generated for King Fahad Dam Lake in Bishah, Saudi Arabia. Data was gathered for period of 22 years. Tests of homogeneity and normality were conducted and results showed that data was homogeneous and normally distributed. For generating annual series, an Autoregressive first order model AR(1) was used and for monthly evaporation series method of fragments was used. Fifty replicates for annual series, and fifty replicates for each month series, each with 22 values length, were generated. Performance of the models was evaluated by comparing the statistical parameters of the generated series with those of the historical data. Annual and monthly models were found to be satisfactory in preserving the statistical parameters of the historical series. About 89% of the tested values of the considered parameters were within the assigned confidence limits

  • PDF

Evaporation Characteristics of a Water Droplet Containing Sodium Acetate Trihydrate as an Additive (첨가제로 아세트산 나트륨-3수화물을 함유한 물 액적의 증발 특성)

  • Park, Jae-Man;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • The evaporation phenomena of waterr droplet which has sodium acetate trihydrate($CH_3COONa{\cdot}3H_2O$) as a fire suppression additive were studied. Solutions of sodium salt up to 50% and heated stainless-steel surface were used in the experiment. The evaporation process was recorded using a charge-coupled-device camera at 120 frames per second. The average evaporation rate of the sodium acetate trihydrate soluation was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid film and change of surface tension. The variation of liquied film diameter was measured by time and it was increased by the hot surface temperature increase.

On Lake Evaporation from Climatological Data in Korea (기후요소에 의한 증발량 연구)

  • 조희구
    • Water for future
    • /
    • v.6 no.1
    • /
    • pp.5-12
    • /
    • 1973
  • A simple regression formula for estimating the lake evaporation rate from the copper-plated pan (diameter 20cm, height 10cm) is derived. A comparison with other formulae indicates that the formula is more accurate than others. An annual map of man evaporation in Korean peninsula has been prepared using the relation. It demonstrates the areal average distribution of mean annual evaporation from a free water surface with no heat storage effect and avected energy owing to differences in the temperature of in-and outflow. The mean annual ratio of the lake to the copper-plated pan evaporation is found to be 0.64. The ratio varies with local conditions from 0.62 to 0.66, and hence it can be considered fairly uniform. However the seasonal variation of the ratio appears to be rather significant. It changes from the lowest of 0.61 to the highest of 0.75.

  • PDF

Experimental Study on Fresh Water Generation System with Low Pressure Evaporation (저압 증발기를 갖는 청수제조 장치에 관한 실험적 연구)

  • Chung, Han-Shik;Wibowo, Supriyanto;Lee, Gyeong-Hwan;Shin, Yong-Han;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.25-30
    • /
    • 2011
  • A fresh water generation system is designed for converting brackish water or seawater into fresh water. In this paper fresh water generation by distillation process that evaporates feed water and subsequently condenses vapor as evaporation product to get fresh water was studied and city water was employed as feed water. The system uses the ejector to create a vacuum, under which liquid can be evaporated at lower temperature than it at normal or atmospheric condition, hence less energy consumption. The effect of various operating conditions i.e. temperature of feed water and different orifice diameters were studied experimentally to investigate the characteristic of the system. It was found that these parameters have significant effect in the performance of fresh water generation system with low pressure evaporation.