• 제목/요약/키워드: Water Efficiency

검색결과 6,704건 처리시간 0.038초

용존이산화탄소부상(DCF) 공정의 입자분리 특성과 부상효율 (Particle Separation and Flotation Efficiency by Dissolved Carbon Dioxide Flotation Process)

  • 곽동희;김성진;정흥조;박양균;유영훈;이영동
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.471-478
    • /
    • 2011
  • A series of laboratory experiments carried out to investigate the particle separation efficiency and flotation characteristics using $CO_2$ bubbles. The primary objective of this study was to find out the feasibility of $CO_2$ bubbles as an applicable unit of flotation process in tap-water and wastewater treatment plant. The fundamental measurements were conducted to characterize the $CO_2$ bubble from the physical viewpoint in water including bubble size distribution and rising velocity under various operational conditions. In addition, the removal efficiency of solid was experimented using the lab scale plant applied $CO_2$ bubbles, namely the dissolved carbon dioxide flotation (DCF) process. The DCF process using carbon dioxide bubble, which is an advantage as the decrease and the reuse of Green-House gas, can be a promising technology as an water treatment process. On the other hand, the further research to decrease the bubble size distribution of $CO_2$ is required to enhance the particle separation efficiency.

저온 열원 활용을 위한 암모니아-물 재생 랭킨 사이클의 성능 해석 (Performance Analysis of Ammonia-Water Regenerative Rankine Cycles for Use of Low-Temperature Energy Source)

  • 김경훈;한철호
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.15-22
    • /
    • 2011
  • It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5kW per unit mass flow rate of source air at $180^{\circ}C$.

생물전기화학기술을 이용한 하수처리장 방류수 수질개선 가능성 (Potential of a Bioelectrochemical Technology for the Polishing of Domestic Wastewater Treatment Plant Effluent)

  • 송영채;오경근
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.351-359
    • /
    • 2015
  • The study on the improvement of discharge water quality from domestic wastewater treatment plant (DWTP) was performed in a filter type bioelectrochemical system. The COD removal efficiency for a synthetic discharge water was about 88%, and the effluent COD was less than 5mg/L. The nitrification efficiency of the bioelectrochemical system was over 97%, but a considerable amount of the nitrogen was remained as nitrate form in the effluent. The total nitrogen removal efficiency was only around 30%. There are no significant differences in the removal of COD and nitrogen at 0.6 and 0.8V of the applied voltages between anode and cathode. The removal of COD and nitrogen in the system were quite stable when the HRT ranged from 60 to 15 minutes, and at 10 minutes of HRT, the nitrification efficiency was slightly decreased. The performance of the bioelectrochemical system has quickly recovered from the shocks in the influent due to high concentration of COD and nitrogen. For the effluent that discharged from the DWTP, the removal efficiencies of COD and total nitrogen from the bioelectrochemical system were 50 and 30%, respectively. Thus the bioelectrochemical system was a feasible process for further polishing the effluent quality from DWTP.

천연광물의 양극성 표면개질을 이용한 상수원수 중 중금속제거 특성 (Heavy Metal Removal from Drinking Water using Bipolar Surface Modified Natural Mineral Adsorbents)

  • 김남열;김영희
    • 한국환경보건학회지
    • /
    • 제45권6호
    • /
    • pp.561-568
    • /
    • 2019
  • Objectives: The most commonly detected heavy metals in rocks and soils, including Pb, Cd, Cu, Fe, Mn and As, are representative pollutants discharged from abandoned mines and have been listed as potential sources of contamination in drinking water. This study focused on increasing the removal efficiency of heavy metals from drinking water resources by surface modification of natural adsorbents to reduce potential health risks. Methods: Iron oxide coating and graft polymerization with zeolites and talc was conducted for bipolar surface modification to increase the combining capacity of heavy metals for their removal from water. The removal efficiency of heavy metals was measured before and after the surface modification. Results: The removal efficiency of Pb, Cu, and Cd by surface modified zeolite showed 100, 92, and 61.5%, respectively, increases compared to 64, 64, and 38% for non-modified zeolite. This implies that bipolar surface modified natural adsorbents have a good potential use in heavy metal removal. The more interesting finding is the removal increase for As, which has both cation and anion characteristics showing 27% removal efficiency where as non-modified zeolite showed only 2% removal. Conclusions: Zeolite is one of the most widely used adsorptive materials in water treatment processes and bipolar surface modification of zeolite increases its applicability in the removal of heavy metals, especially As.

수소 연료생산의 효율 향상을 위한 초음파 응용에 관한 연구(LSV에 의한 과전압 저감 중심으로) (A Study on the Ultrasonic Application for the Efficiency Elevation of Hydrogen Fuel Production (On the Decrease of Overpotential by LSV))

  • 주은선;박영철;송민근;손승우
    • 한국수소및신에너지학회논문집
    • /
    • 제14권3호
    • /
    • pp.187-194
    • /
    • 2003
  • The production of hydrogen fuel depends basically on the water electrolysis. The study on the decrease of overpotential which activates the hydrogen production is the core to elevate the hydrogen production efficiency on principle. Characteristics on the overpotential decrease are observed through the micro reaction by ultrasonic in electrolytic cell. For the above, the electrochemical analyzer, i.e., BAS is applied, Experiments with ultrasonic forcing into 4 kinds of solution such as city water, city water plus nitrogen. distilled water, and distilled water plus nitrogen are carried out. And concentrations of KOH are 0%, 10%, 20% and 30%. The basic characteristics of the overpotential decrease are obtained through the analysis by LSV technique in sweep technique. In results, it is clarified that the ultrasonic influences the decrease of overpotential to obtain the efficiency elevation of hydrogen fuel production.

섬모상 매트에 의한 탁수이동차단에 관한 실험적 연구 (Control of Turbid Water Transport with Filamentous Mat)

  • 유지앙화;이치타오;김영철
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.44-51
    • /
    • 2010
  • A lab-scale apparatus for turbid water transport control was tested and examined. The channel had a dimension of $100cm{\times}30cm{\times}15cm$ (length${\times}$hight${\times}$width). And the turbidity water was prepared using two types of particles, bentonite and loess. The channel equipped with filamentous mat was operated under various shock load conditions. In the control channel, instantly, turbid water mixed with the clean water inside the channel and turbidity prevails the entire channel. While in the mat-equipped channel, it increases only at the bottom. Overall, the filamentous mat gave capture efficiency of 70~90% compared with the control group. The capture efficiency of turbid particles decreased with increased input turbidity flux. The result of experimental run on how turbid particles are separated in the mat channel shows that settling, filtration and attachment are the main processes. Meanwhile, turbidity was diffused from the channel bottom due to turbidity gradient before and after mat zone. The particle size before mat zone was lightly coarser than that after mat zone.

기후변화 대응 물 효율성 증대를 위한 스마트 관개기술 연구 (Smart irrigation technique for agricultural water efficiency against climate change)

  • 김민영;전종길;김영진;최용훈
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.198-198
    • /
    • 2017
  • Climate change causes unpredictable and erratic climatic patterns which affects crop production in agriculture and threatens public health. To cope with the challenges of climate change, sustainable and sound growth environment for crop production should be secured. Recent attention has been given to the development of smart irrigation system using sensors and wireless network as a solution to achieve water conservation as well as improvement in crop yield and quality with less water and labor. This study developed the smart irrigation technique for farmlands by monitoring the soil moisture contents and real-time climate condition for decision-making support. Central to this design is micro-controller which monitors the farm condition and controls the distribution of water on the farm. In addition, a series of laboratory studies were conducted to determine the optimal irrigation pattern, one time versus plug time. This smart technique allows farmers to reduce water use, improve the efficiency of irrigation systems, produce more yields and better quality of crops, reduce fertilizer and pesticide application, improve crop uniformity, and prevent soil erosion which eventually reduce the nonpoint source pollution discharge into aquatic-environment.

  • PDF

수소수 급수시 오리생산성에 미치는 영향 -현장연구를 중심으로- (Effects of Using Hydrogen Water on Duck Production in A Field Study)

  • 정태호
    • 한국환경과학회지
    • /
    • 제31권3호
    • /
    • pp.291-294
    • /
    • 2022
  • This study was conducted to investigate the effect of hydrogen water on duck production in a field study. A total of 600 one-day-old ducks (Pekin) were randomly allotted to two treatment groups with three replicates each having 100 birds per pen in a completely randomized design. The duck production parameters measured included weight gain, feed intake, and feed efficiency. For duck drinking water, general water supplied from the farm was used as the control, and hydrogen water was supplied by installing a device that generates hydrogen (T1 groups). There was no statistical significance in duck weight gain between the two treatment groups (p>0.05). In addition, no significant difference in feed intake was found in both the control and T1 groups (p>0.05), and the range of values was similar. Feed efficiency was not significant different between the treatment groups (p>0.05), and there was no remarkable difference in the range of vaules. These results indicate that hydrogen water did not influence duck production.

태양 열 전기 복합생산 PVT Water and PVT Air 모듈의 실험적 성능비교 연구 (An Experimental Comparison Study of PVT Water and PVT Air Modules for Heat and Power Co-Generation)

  • 이광섭;앤드류;강은철;이의준
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.559-564
    • /
    • 2014
  • The development of photovoltaic-thermal (PVT) technology has been introduced in recent years specifically to increase PV efficiency. One of the characteristics of PV systems is that the electricity generation increases as the solar radiation increases whereas the efficiency decreases because of high surface temperatures. Using a photovoltaic-thermal system, the surface temperature can be decreased by capturing the excess heat and the efficiency can be increased due to these characteristics. In this paper, three cases are introduced : 1) PV_r as the reference case, 2) PVT_a, which uses air as a heat source, and 3) PVT_w, which uses water as a heat source. Experiments were performed, analyzed, and compared to examine the effect of the PVT type on the efficiency of the system. The results showed that ETC($%/^{\circ}C$) efficiency of the PVT cases was increased versus the reference case due to decreasing surface temperature. Total efficiencies, which are electrical efficiency and thermal efficiency, for each PVT are tested and found to be 12.22% for PV_r, 29.50% for PVT_a, and 68.74% for PVT_w.

동진지구 관개용수로의 손실률 및 관개효율 분석 (Analysis of Water Loss Rate and Irrigation Efficiency in Irrigation Canal at the Dong-Jin District)

  • 홍은미;최진용;남원호;이상현;최진규;김진택
    • 한국농공학회논문집
    • /
    • 제57권2호
    • /
    • pp.93-101
    • /
    • 2015
  • The purpose of this study is to evaluate the paddy irrigation efficiency using real-time water level monitoring data and intermittent irrigation model in Gimjae, Dong-Jin irrigation district. For this study, the real-time water level data in Gimjae main canal and other secondary canals were collected from 2012 to 2014 and converted to daily discharge using rating curve in each canal. From intermittent irrigation model in paddy, irrigation water requirement was estimated and irrigation efficiency was calculated. The average amount of irrigation water supply per unit irrigation area was 1,011 mm in Gimjae main canal for 12,749 ha irrigation area, 1,011 mm in the secondary canal of upper region and 1,470 mm in the secondary canal of lower region. The median irrigation loss was 43 % in Gimjae main canal, 25 % in secondary canal of upper region and 35 % in the secondary canal of lower region. The larger irrigation area is, the irrigation loss rates tend to decrease in secondary canals. Monthly median irrigation losses in upper region were 10 (June) - 40 % (September) and those in lower region were 25 (May) to 40 % (April, June, August, and September). The results of canal management loss can be available as the basic data for irrigation water management and estimating guideline of optimal irrigation water supply to improve agricultural water use efficiencies.