• 제목/요약/키워드: Water Cycle Ratio

검색결과 224건 처리시간 0.024초

GIS 기반의 물순환 면적률을 활용한 창원시 도심지역의 물순환성 평가 (An Assessment of Urban Water Cycle in Changwon-si Using GIS-based Water Cycle Area Ratio)

  • 송봉근;박경훈;이택순
    • 환경영향평가
    • /
    • 제22권5호
    • /
    • pp.397-408
    • /
    • 2013
  • The purpose of this study is to analyze water cycle area ratio and spatial evaluation of water cycle in urban area of Changwon-si, Gyeongsangnam-do. Water cycle area ratio are analyzed by using spatial data of land-cover and land-use, and Hot spot analysis of GIS program was used for spatial evaluation of water cycle. The results are as below. Firstly, the high water cycle area ratio areas were forests, parks, and rivers, but urban areas covered asphalt and concrete were low under 40%. Public institutions and co-residential of urban areas were higher than others because of high area ratio of pervious land-cover. Spatial evaluation of water cycle was analyzed to vulnerable areas there are dense residential and commercial area. These areas are really occurring frequently flooding and immersion, therefore, is required water management facilities and improvement of land-cover from impervious to pervious. In the future, it will require additionally analysis of water cycle area ratio supplemented data of water management facility and ground water.

칼로리/수분 (C/W)비를 고려한 고온호기 처리법에서의 처리량 증가 (Increase of treatment amount of thermophilic oxic process considering calorie/water (C/W) ratio)

  • 전경호;최동윤;송준익;박규현;곽정훈;김재환;강희설
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.203-210
    • /
    • 2010
  • The signification of calorie/water (C/W) ratio was investigated in the treatment of highly concentrated organic wastes by thermophilic oxic process (TOP). Swine waste was used in this study. When C/W ratio was 1.6, most of swine waste was decomposed and all water was evaporated in the 24-h injection cycle. To improve treatment efficiency of TOP treating swine waste, the effect of shortening the swine waste injection cycle was examined. The shortening of injection cycle was conducted to stimulate the activity of thermophilic bacteria. A high temperature in the reactor was maintained by shortening of the injection cycle. When the swine waste injection cycle was shortened, the C/W ratio was fixed at 1.6. As a result, by shortening the swine waste injection cycle from 24-h to 12 and 6-h, the maximum loading rate of swine waste per day could be improved 1.9 and 3.5 times, respectively.

유기랭킨사이클과 암모니아-물 랭킨사이클의 열역학적 성능의 비교 해석 (Comparative Thermodynamic Analysis of Organic Rankine Cycle and Ammonia-Water Rankine Cycle)

  • 김경훈;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권5호
    • /
    • pp.597-603
    • /
    • 2016
  • In this paper a comparative thermodynamics analysis is carried out for organic Rankine cycle (ORC) and ammonia-water Rankine cycle (AWRC) utilizing low-grade heat sources. Effects of the working fluid, ammonia concentration, and turbine inlet pressure are systematically investigated on the system performance such as mass flow rate, pressure ratio, turbine-exit volume flow, and net power production as well as the thermal efficiency. Results show that ORC with a proper working fluid shows higher thermal efficiency than AWRC, however, AWRC shows lower mass flow rate of working fluid and lower pressure ratio of expander than ORC.

도시 용수 통합관리 방안 연구 (An application of integrated water cycle system in U-City)

  • 정진홍;최계운;오현제
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6597-6601
    • /
    • 2013
  • 인구 증가와 함께 도시개발로 인한 지구온난화의 심각, 대기질 악화, 수질 오염 및 수생태계 파괴 등 도시환경 문제가 심화되고 있다. 또한 도시 개발 시 토지 피복면적 변화에 따른 불투수층 면적이 증가되는 인공적 요인과 이상기후에 의해 강우특성이 변화하는 자연적 요인으로 도시 열섬현황 심화, 용수 부족, 지하수위 저하, 침수 피해 등을 야기하여 물순환 건전성을 저해시키고 있다. 이를 해결하기 위해서는 체계적인 정보기술 인프라 및 환경센서 기술을 활용하여 도시 물순환 건전성을 제고시키기 위한 물순환시스템 구축기술 개발이 필요하다. 본 연구에서는 도시 내에서 물순환 건전성을 평가하는 방법으로 자연계 물순환 건전화율 및 인공계 물순환 건전화율 평가식을 제시하여, 도시화 및 산업화로 인해 발생하는 물순환 왜곡 정도를 정량적으로 분석하고, 도시 개발 후 물순환 건전성을 확보하기 위한 방법론을 제시하였다.

습식 압축을 채용한 재생 가스터빈 사이클의 엑서지 해석 (Exergy Analysis of Regenerative Wet-Compression Gas-Turbine Cycles)

  • 김경훈;김세웅;고형종
    • 에너지공학
    • /
    • 제18권2호
    • /
    • pp.93-100
    • /
    • 2009
  • 습식압축으로 압축소요동력을 줄이고 재생기로 배기가스 에너지를 회수함으로써 열효율을 향상시킬 수 있는 습식압축 재생 브레이튼 사이클에 대하여 엑서지 해석을 수행하였다. 해석모델을 통하여 시스템의 엑서지 효율과 요소별 엑서지 파괴비 및 배기가스로 인한 엑서지 손실비에 미치는 압력비와 물분사율의 영향을 조사하였다. 전형적인 운전조건에 대한 계산 결과 습식압축 재생 가스터빈 사이클에 의하여 엑서지 효율을 상당히 향상시킬 수 있음을 확인하였다. 물 분사 효과는 배기가스의 엑서지 손실의 감소와 출력 동력의 증가로 나타난다.

압축비가 기관의 방열에 미치는 영향 (Effect of compression ratio on the heat dissipation of engine)

  • 이창식
    • 오토저널
    • /
    • 제5권1호
    • /
    • pp.89-93
    • /
    • 1983
  • This paper describes on experimental investigation into the heat dissipation of Diesel engine, placing emphasis on the variations of compression ratio and cooling water temperature. The engine used for this test was a vertical single-cylinder four-cycle type, having a direct injection. Engine performance and heat transfer rates was tested under the compression ratio 14.3 and 17.4. In this study, the results showed that output and transfer rates of engine decrease in accordance with the decrease of compression ratio. The effect of cooling water temperature and injection delay of fuel on the heat dissipation brings about the decrease of heat transfer rates from cylinder to cooling water.

  • PDF

물의 T-s 선도 상에서 엑서지 및 엑서지율의 고찰 (Consideration of Exergy and Exergy Ratio on T-s Chart of Water)

  • 김덕진;김덕봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.827-832
    • /
    • 2009
  • Exergy is the amount of reversible work obtainable when some matter is brought to a state of thermodynamic equilibrium with ambient. This exergy is availability or useful work induced from carnot cycle, and this can calculate the irreversible loss work which occurs within any thermal or power cycle. The exergy ratio is the value of exergy divided by enthalpy of ambient reference, where the quality of energy or enthalpy in substances is evaluated by exergy ratio. Exergy is very important in optimal design method of thermal system or each component, and the value of exergy at given state is calculated by equation. Here, designer can easily understand and find the value of enthalpy because enthalpy is graphically drawn in chart, however exergy did not. In this paper, exergy and exergy ratio of air were drawn on temperature-entropy chart, and we wish to this chart is a help to design, analysis and education.

  • PDF

고성능 흡수냉동 사이클의 특성 시뮬레이션 (Simulation of the Characteristics of High-Performance Absorption Cycles)

  • 윤정인;오후규;이용화
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

Safety margin and fuel cycle period enhancements of VVER-1000 nuclear reactor using water/silver nanofluid

  • Saadati, Hassan;Hadad, Kamal;Rabiee, Ataollah
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.639-647
    • /
    • 2018
  • In this study, the effects of selecting water/silver nanofluid as both a coolant and a reactivity controller during the first operating cycle of a light water nuclear reactor are investigated. To achieve this, coupled neutronic-thermo-hydraulic analysis is employed to simulate the reactor core. A detailed VVER1000/446 reactor core is modeled in monte carlo code (MCNP), and the model is verified using the porous media approach. Results show that the maximum required level of silver nanoparticles is 1.3 Vol.% at the beginning of the cycle; this value drops to zero at the end of cycle. Due to substitution of water/boric acid with water/Ag nanofluid, reactor operation time at maximum power extends to 357.3 days, and the energy generation increases by about 27.3%. The higher negative coolant temperature coefficient of reactivity in the presence of nanofluid in comparison with the water/boric acid indicates that the reactor is inherently safer. Considering the safety margins in the presence of the nanofluid, minimum departure from nucleate boiling ratio is calculated to be 2.16 (recommendation is 1.75).

하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션 (Simulation of a two-stage absorption heat pump cycle using treated sewage)

  • 이용화;신현준;최국광
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF