• Title/Summary/Keyword: Water Consumption

Search Result 1,954, Processing Time 0.031 seconds

Influence of Water Temperature and Salinity on Oxygen Consumption and Filtration Rate of on Oxygen Consumption and Filtration Rate of Ark Shell, Anadara granosa bisenensis

  • Kang, Kyoung-Ho;Kim, Jae-Min;Kim, Young-Hun
    • The Korean Journal of Malacology
    • /
    • v.20 no.2
    • /
    • pp.107-110
    • /
    • 2004
  • The filtration rate and oxygen consumption of Anadara granosa bisenensis were measured at 4 different temperature (10$^{\circ}C$, 15$^{\circ}C$, 20$^{\circ}C$, and 25$^{\circ}C$) and 4 different salinity levels (20, 25, 35, and 40 psu), using an direct method under laboratory conditions. The samples were divided into two groups: a large-sized group (shell length: 34.58 ${\pm}$ 2.23 mm, body weight: 12.43 ${\pm}$ 0.44 g) and a small-sized group (shell length: 20.60 ${\pm}$ 0.85 mm, body weight: 4.41 ${\pm}$ 2.30 g). Filtration rate and oxygen consumption increased with the increase of various temperatures and salinity levels. Also, the filtration rate and oxygen consumption of the small-sized group were higher than those of the large-sized group. These results indicate that the filtration rate and oxygen consumption of Anadara granosa bisenensis depends on environmental conditions, especially on water temperature and salinity.

  • PDF

Pilot-Scale Simulation of Desalination Process Using Water Integrated Forward Osmosis System (물통합형 정삼투 시스템을 이용한 파일럿 스케일 담수 공정 모사)

  • Kim, Bongchul;Hong, Seungkwan;Choi, Juneseok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.403-408
    • /
    • 2017
  • In these days, wastewater reclamation and seawater desalination play essential role in addressing the challenge of worldwide water scarcity. Particularly, reverse osmosis (RO) for seawater desalination process is commonly used due to less energy consumption than conventional thermodynamic systems. However, membrane fouling and electrical energy consumption during operation of RO system for seawater desalination haver continued to be a obstruction to its application. In this study, therefore, wastewater secondary effluent is used for osmotic dilution of seawater. Firstly, fouling behaviour of RO by simulating wastewater effluent in osmotic dilution process was measured and we calculated energy consumption of overall desalination process by theoretical equations and commercial program. Our results reveal that RO membrane fouling can be efficiently controlled by pre-treatment systems such as nano filtration (NF) or forward osmosis (FO) process. Especially FO system for osmotic dilution process is a non-pressurized membrane system and, therefore, the operating energy consumption of overall desalination system was the lowest. Moreover, fouling layer on FO membrane is comparatively weak and reversible enough to be disrupted by physical cleaning. Thus, RO system with low salinity feed water through FO process is possible as a less energy consuming desalination system with efficient membrane fouling control.

Effects of Water Temperature and Salinity on Blood Properties and Oxygen Consumption in Hagfish (Eptatretus burgeri) (먹장어(Eptatretus burgeri)의 혈액성상과 산소소비에 미치는 수온 및 염분의 영향)

  • Do, Yong-Hyun;Min, Byung-Hwa;Myeong, Jeong-In;Jee, Young-Ju;Chang, Young-Jin
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.1
    • /
    • pp.214-222
    • /
    • 2014
  • Hagfish Eptatretus burgeri is classified as a agnathans and has many different physiological properties compared with vertebrates. In this study, we examined effects of water temperature and salinity on blood properties and oxygen consumption in hagfish. In the experiment of water temperature change, hematocrit (Ht), red blood cell (RBC) and glucose of hagfish blood revealed the lowest values at $15^{\circ}C$. Oxygen consumption of hagfish had significantly increased with rising water temperature, and the increasing rate was twice as much when the temperature was manipulated every $5^{\circ}C$. Also, oxygen consumption during the night time (a short photoperiod) was significantly higher than that of the daytime. Q10 level was 3.50 in the light period and 3.92 in the dark period. No significant change in plasma glucose level was showned in changing salinity from 30 psu to 22 psu, while it had rapidly increased at 20 psu ($13.7{\pm}4.0mg/dL$) and thereafter all hagfish were dead at 18 psu. However, osmolarity, $Na^+$, $K^+$ and $Cl^-$ levels had significantly decreased when salinity decreased. This results are expected to develop the artificial rearing techniques of natural hagfish.

An Assessment of Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 평가)

  • Kim, Ki-Cheol;Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Shin, Dae-Kun;Park, Dug-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.55-63
    • /
    • 2013
  • For a large-scale semiconductor manufacturing clean room, the energy consumed in an outdoor air conditioning system to heat, humidify, cool and dehumidify incoming outdoor air is very large. In particular, the energy requirement to humidify outdoor air in the winter season is generally known to be high. Recently, in order to overcome the high energy consumption nature of a steam generator in a conventional steam humidification type outdoor air conditioning system, an air washer is often introduced instead of the steam generator in the outdoor air conditioning system, which can be called a water spray humidification type outdoor air conditioning system. Therefore, the assessment and comparison of the annual energy consumed in the steam humidification type and the water spray humidification type outdoor air conditioning systems deserves to be examined in order to reduce the outdoor air conditioning load of a clean room. In the present study, a numerical analysis was conducted to obtain the annual electric power consumption of the two outdoor air conditioning systems. It was shown from the comparison of the numerical results that the water spray humidification type outdoor air conditioning system can reduce about 30% of annual electric power consumption of the steam humidification type outdoor air conditioning system.

Dynamic Model of a Long-term Water Demand Using System Dynamics (시스템 다이나믹스를 이용한 도시 물수요 장기 예측의 동적 모델 연구)

  • Lee, Sangeun;Choi, Dongjin;Park, Heekyungh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.75-82
    • /
    • 2007
  • When one forecasts urban water demand in a long-term, multivariate model can give more benefits than per capita requirement model. However, the former has shortcomings in that statistically high explanatory power cannot be obtained well, and change in customer behavior cannot be considered. If the past water consumption effects the future water demand, dynamic model may describe real water consumption data better than static model, i.e. the existing multivariate model. On these grounds, this study built dynamic model using system dynamics. From a case study in Seoul and Busan city, dynamic model was expected to forecast water demand more descriptively and reliably.

Effect of Feed Intake and Water Consumption on Milk Yield and Manure Production in Milking Cows (착유우의 사료섭취량과 음수량이 산유량과 분뇨 배설량에 미치는 영향)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Yoo, Y.H.;Yang, C.B.;Choi, H.L.;Ahn, H.K.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.1
    • /
    • pp.21-28
    • /
    • 2007
  • This experiment was conducted to determine the effect of feed intake and water consumption on milk yield and manure production in milking cows. The average feed intake(dry matter) of milking cows were 19.5kg/hd/d. Spring(23.9kg) and fall(22.1kg) feed intake rates when higher than in the summer(17.0kg) and winter(15.3kg/hd/d). The average water consumption of milking cows were $77.2\ell/hd/d$. Summer showed the highest value$(85.5\ell/hd/d)$ and winter showed the lowest value$(62.2\ell/hd/d)$. The average milk yield during spring, summer, fall, and winter was 30.8, 24.0, 25.4, and 23.7kg/hd/d, respectively. Milk yield during spring was found to be statiscally greater than for the other seasons. Manure production of milking cows during spring, summer, fall, and winter was 64.4, 63.5, 60.4, and 51.0kg/hd/d, respectively. Consequently, a relatively high correlation between milk yield and water consumption$(R^2=0.7742)$, milk yield and feed intake$(R^2=0.7459)$, water, consumption and urine production$(R^2=0.7422)$, feed intake and feces production$(R^2=0.6044)$, and milk yield and feces production$(R^2=0.6920)$ were observed in milking cows. The other hand, correlation between water consumption and feces production$(R^2=0.2950)$, feed intake and urine production $(R^2=0.1985)$, and milk yield and urine production$(R^2=0.2335)$ were found to be relatively low. Therefore, correlation equation between milk yield and feed intake, milk yield and water consumption can be estimated from : $Y=0.1919X_1+11.181(R^2=0.7742),\;Y=0.8568X_2+9.3067(R^2=0.7459)$(Y=milk yield $X_1=water$ consumption, $X_2=feed$ intake).

  • PDF

Optimal Control for Central Cooling Systems (중앙냉방시스템의 최적제어에 관한 연구)

  • 안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.354-362
    • /
    • 2000
  • Optimal supervisory control strategy for the set points of controlled variables in the central cooling system has been studied by computer simulation. A quadratic linear regression equation for predicting the total cooling system power in terms of the controlled and uncontrolled variables was developed using simulated data collected under different values of controlled and uncontrolled variables. The optimal set temperatures such as supply air temperature, chilled water temperature, and condenser water temperature, are determined such that energy consumption is minimized as uncontrolled variables, load, ambient wet bulb temperature, and sensible heat ratio, are changed. The chilled water loop pump and cooling tower fan speeds are controlled by the PID controller such that the supply air and condenser water set temperatures reach the set points designated by the optimal supervisory controller. The influences of the controlled variables on the total system and component power consumption was determined. It is possible to minimize total energy consumption by selecting the optimal set temperatures through the trade-off among the component powers. The total system power is minimized at lower supply, higher chilled water, and lower condenser water set temperature conditions.

  • PDF

The Development of Model for the Prediction of Water Demand using Kalman Filter Adaptation Model in Large Distribution System (칼만필터의 적응형모델 기법을 이용한 광역상수도 시스템의 수요예측 모델 개발)

  • 한태환;남의석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.38-48
    • /
    • 2001
  • Kalman Filter model of demand for residental water and consumption pattern wore tested for their ability to explain the hourly residental demand for water in metro-politan distribution system. The daily residental demand can be obtained from Kalman Filter model which is optimized by statistical analysis of input variables. The hourly residental demand for water is calculated from the daily residental demand and consumption pattern. The consumption pattern which has 24 time rates is characterized by data granulization in accordance with season kind, weather and holiday. The proposed approach is applied to water distribution system of metropolitan areas in Korea and its effectiveness is checked.

  • PDF

Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

Studies on the Consumptive Use of Irrigated Water in Upland (田作物 水分消費量 調査 硏究)

  • Kim, Shi-Won;Lee, Kyong-Hi;Doh, Duk-Hyun
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.26 no.2
    • /
    • pp.47-58
    • /
    • 1984
  • The study results of the mosture consumption character and irrigation effect of tomato, red pepper and chinese cabbage, in case the soil moisture is kept with different moisture content by the soil properties(loam, sandy loam, sand), are summarized as follows: 1. The available rainfall under bare soil condition had an order of sand>sandy loam> loam and their average was 64.2%. 2. Total moisture consumption under bare soil condition had an order of loam>sandy loam>sand and their average was 4.2mm. 3. The amount of irrigated water to keep certain soil moisture under bare soil condition showed minimum in sand and maximum in loam. It is considered because the capillary phenomenon was more developed in loam. 4. Total moisture consumption of tomatoes under premature cultivation showed 925mm in maximum and had on order of loam>sandy loam>sand. In the aspect of re-irrigation point, it had an order of PF 1.5> PF 1.7>PF 2.1. In case the twenty years's drought frequency was taken into account, the target amount of irrigation water meeded for premature cultivation was 916mm and its average daily moisture consumption was 10.8mm. 5. Total moisture consumption of red pepper under open cultivation showed 1145mm in maximum and had an order of loam>Sandy loam>sand. In the aspect of re-irrigation frequency was taken into consideration the target amount of irrigation water was 1,174.8mm and its average daily moisture consumption was 8.0mm. 6. Total moisture consumption of autumn chinese cabbages was 349mm in maximum and had an order of loam>sandy loam>sand. In the aspect of re-irrigation point, it had an order of PF 1.5>PF 2.1>PF 2.7. In case the twenty year's drought frequency was taken into account, the target amount of irrigation water needed for chinese cabbage cultivation was 259.5mm and its average daily moisture consumption was 6.5mm. 7. It is effective to keep the soil moisture of tomato from PF 1.5 to PF 2.1 in loam and the soil moisture control was effective in sandy loam than red pepper and chinese cabbage. In sand, the production was severaly decreased and the re-irrigation point of PF 1.5 was effective.

  • PDF