• Title/Summary/Keyword: Water Consumption

Search Result 1,957, Processing Time 0.024 seconds

A Study on the Trend Analysis of Real-time Residential Water Consumption (주거용수 실시간 사용 추세패턴 분석)

  • Kim, Seong-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3757-3763
    • /
    • 2012
  • This study ultimately aims at proposing an IT-based efficient method to solve one of the biggest problems currently faced by human beings which is lack of water. As a trial, targeting residential water, a chain of efforts was added such as choosing an appropriate field area and a censor, installing a sensor and the communication systems and servers, and monitoring the real time residential water consumption data. Then, a series of residential water consumption models was developed through the analyses of data gathered. And using the developed models, a series of trend analyses was performed for the residential water consumption. The research results shows that the developed models can be generalized and utilized for the water supply management purpose individually or along with the ones from the other water categories.

Evaluation of energy consumption of gas hydrate and reverse osmosis hybrid system for seawater desalination (해수담수화 공정을 위한 가스하이드레이트-역삼투 공정의 에너지 소모량 평가)

  • Ryu, Hyunwook;Kim, Minseok;Lim, Jun-Heok;Kim, Joung Ha;Lee, Ju Dong;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.459-469
    • /
    • 2016
  • Gas hydrate desalination process is based on a liquid to solid (Gas Hydrate, GH) phase change followed by a physical process to separate the GH from the remaining salty water. The GH based desalination process show 60.5-90% of salt rejection, post treatment like reverse osmosis (RO) process is needed to finally meet the product water quality. In this study, the energy consumption of the GH and RO hybrid system was investigated. The energy consumption of the GH process is based on the cooling and heating of seawater and the heat of GH formation reaction while RO energy consumption is calculated using the product of pressure and flow rate of high pressure pumps used in the process. The relation between minimum energy consumption of RO process and RO recovery depending on GH salt rejection, and (2) energy consumption of electric based GH process can be calculated from the simulation. As a result, energy consumption of GH-RO hybrid system and conventional seawater RO process (with/without enregy recovery device) is compared. Since the energy consumption of GH process is too high, other solution used seawater heat and heat exchanger instead of electric energy is suggested.

Analysis of Domestic Water Consumption Characteristics for Water Usage Purpose (가정용수의 사용 목적별 소비경향 특성분석)

  • Choi, Sun-hee;Son, Mi-na;Kim, Sang-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.23-29
    • /
    • 2008
  • Throughout the analysis of field data from water distribution system, valid parameters were determined that can be included in the water service and design plan. This study investigates water consumption patterns to understand the variation of water-demand structures utilizing the pattern analysis of domestic purpose water. Water use data were collected by a public water resources management firm in Korea, Kwater, for 140 houses monitored during three years. Flow meters were installed at the faucet for drinking water, the shower booth, the laundry machine, bathroom sink, toilet, and garden faucet. Data was filtered using multiple physically meaningful criteria to improve analysis credibility. Mann Kendall and Spearman's Rho tests were used to carry out the analysis. Distinct factors of water consumption patterns can be determined for both increasing and decreasing trends of water use. Throughout the data analysis, the characterization of terms was classified and analyzed by the condition of the location of water-demand. Analysis of this data provide a physical basis for the parameter configuration of a reasonable design for a domestic water demand prediction model.

Methods for the Reduction of Consumption and Contamination of Water in a Newsprint Mill by Using Simulation Model and WRDF (전산모사기법과 WRDF를 활용한 ONP 재활용 공정의 용수 및 오염부하 절감 방안에 관한 연구)

  • 이영애;류정용;성용주;김용환;송재광;송봉근;서영범
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.2
    • /
    • pp.54-59
    • /
    • 2004
  • The methods for the minimization of fresh water consumption, waste water generation and water contamination have been greatly investigated and developed for last ten years. Recently, the rising cost of waste water treatment and the more strict environmental regulation lead to the higher demand of more efficient and systematic methods for process water management. The water reuse technology, which not only reduce the process water needs but also minimize waste water generation within the process, could be one of most efficient way for current demand. In this study, the practical way for reduction of water pollution and optimal reuse or recycle of process water in a newsprint mill was investigated by using a simulation model. The result of computer simulation showed that the COD level of approach system could be reduced by 50% after the stock concentration at the 2nd disc filter was increased upto 30%. The application of WRDF(Wrinkled Rotary Drum Filter) to the newsprint mill was carried out with pilot scale. The process water treated by WRDF had enough cleanliness to substitute the forming fabric shower water with the PDF water, which could result in the 30% reduction in fresh water consumption.

Assessment of Water Productivity & Potential Water Consumption of Rice by Each Province (벼에 대한 지역별 물 생산성 및 잠재 물 소비량 평가)

  • Hur, Seung-Oh;Choi, Soonkun;Yeop, Sojin;Hong, Seong-Chang;Choi, Dong-Ho
    • Journal of Korean Society of Rural Planning
    • /
    • v.25 no.4
    • /
    • pp.27-33
    • /
    • 2019
  • Agricultural water for crops are faced with the need to improve the use efficiency due to the impact of climate change. Water productivity (WP) is known as a good indicator for assessing resources efficiency. This study was conducted to assess WP of rice and potential water consumption (PWC) as new indicator for water use efficiency assessment. The average of WP was 0.7 kg/㎥, and Jeonbuk had the highest WP as 0.83 kg/㎥. Kangwon and Kyungbuk had the lowest WP as 0.59 kg/㎥. PWC showed the same trend because of rice consumption per capita, but Total PWC considering population living in each province showed the different trend with PWC. Every year, the changing patterns of WP was increasing little by little, and the patterns of PWC was decreasing greatly than WP. These results mean that WP has been slowly improved through breed development and irrigation techniques, and PWC was affected by reduced rice consumption and WP increasing. PWC could also be useful as an indicator to compare the water use efficiency between provinces or nations.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구)

  • Seo, Youn-Kyu;Kim, Ju-Young;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

Human Health Effects due to Consumption of Low TDS Water (물이 인체 건강에 미치는 영향)

  • Rozelle, Lee T.
    • Membrane Journal
    • /
    • v.6 no.4
    • /
    • pp.189-195
    • /
    • 1996
  • It is concluded from this study that human consumption of very low TDS water does not leach minerals from the body that cause ill health effects because; -The human body's own control mechanism of homeostasis and internal body secretions keep tight controls on body fluid composition regardless of drinking water TDS for a normal person under normal csonditions. -The unofficial WHO document's proposed guideline of a 100m/l lower limit for drinking water due to mineral leaching and subsequent ill health was not found to be scientifically or physiologically credible. Leaching of minerals from the body is not officially recognized by WHO. -The experience of the U.S. Navy, Army, NASA and dommunity demonstrations do not support ill health symptoms caused by consumption of low TDS drinking water. -Millions of people regularly consume maturally occurring low TDS water without symptoms of ill health.

  • PDF

Effect of Water Temperature and Photoperiod on the Oxygen Consumption of Four Different Strains of Red Seabream, Pagrus major

  • Oh, Sung-Yong;Choi, Hee Jung;Kim, Min-Suk;Park, Yong Joo;Myoung, Jung-Goo;Kwon, Joon Yeong;Choi, Cheol Young
    • Journal of Marine Life Science
    • /
    • v.1 no.2
    • /
    • pp.109-116
    • /
    • 2016
  • We determined the effects of different water temperatures (15, 20, and 25℃) and photoperiod cycles (24L:0D, 12L:12D, and 0L:24D) on the oxygen consumption of the offspring of a cultured Japanese strain (JJ), a selected Korean strain (KK), and intraspecific hybrid strains (JK and KJ) of red seabream, Pagrus major, under starvation conditions. The different fish strains, water temperatures, and photoperiod cycles had effects on the mean oxygen consumption of fish. Oxygen consumption increased with increasing water temperatures for all photoperiod treatments (p<0.001). Fish held in continuous darkness (0L:24D) used consistently less oxygen than fish exposed to continuous light (p<0.05). The oxygen consumption of fish exposed to the light phase in a 12L:12D photoperiod was higher than that of fish in the dark phase of the 12L:12D cycle, and differences were significant in three of the strains: JJ (15℃), KK (15 and 20℃), and KJ (25℃). The oxygen consumption of the inbred (JJ and KK) and intraspecific hybrid (JK and KJ) strains varied with differing water temperatures and photoperiod cycles. The JK strain displayed significantly higher oxygen consumption than the other strains under all experimental conditions except 15℃ with a 0L:24D photoperiod. The JK and KJ strains usually showed the highest and lowest oxygen consumption values, respectively, whereas the inbred strains exhibited intermediate values. Oxygen consumption in the JJ and JK strains was usually higher than that of the KK and KJ strains. We propose that differences in the thermal sensitivity and photosensitization properties of the strains contribute to differences in their ability to adapt to changes in water temperature and photoperiod, thus resulting in differences in the amplitude of their metabolic rates.

Hydrological Evaluation of Rainwater Harvesting: 2. Hydrological Evaluation (빗물이용의 수문학적 평가: 2. 수문학적 평가)

  • Kim, Kyoungjun;Yoo, Chulsang;Yun, Zuhwan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.230-238
    • /
    • 2008
  • This study evaluated the economic aspect of the rainwater harvesting facilities by hydrologically analyzing the inflow, rainwater consumption, rainfall loss, tank storage, and overflow time series to derive the net rainwater consumption and the number of days of rainwater available. This study considers several rainwater harvesting facilities in Seoul National University, Korea Institute of Construction Technology and Daejon World Cup Stadium and the results derived are as follows. (1) Increasing the water consumption decreases the number of days of rainwater available. (2) Due to the climate in Korea, a larger tank storage does not increase the amount and the number of days of water consumption during wet season (June to September), but a little in October. (3) Economic evaluation of the rainwater harvesting facilities considered in this study shows no net benefit (private benefit). (5) Flood reduction effect of rainwater harvesting facilities was estimated very small to be about 1% even in the case that 10% of all the basin is used as the rainwater collecting area.