• Title/Summary/Keyword: Water Cleaning

Search Result 698, Processing Time 0.028 seconds

Synthesis of Ag-doped black ZnO nano-catalysts for the utilization of visible-light (가시광선 활용을 위한 Ag 도핑 흑색 ZnO 나노 광촉매 합성)

  • Ui-Jun Kim;Hye-Min Kim;Seung-Hyo Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.3
    • /
    • pp.208-218
    • /
    • 2023
  • Photocatalysts are advanced materials which accelerate the photoreaction by providing ordinary reactions with other pathways. The catalysts have various advantages, such as low-cost, low operating temperature and pressure, and long-term use. They are applied to environmental and energy field, including the air and water purification, water splitting for hydrogen production, sterilization and self-cleaning surfaces. However, commercial photocatalysts only absorb ultraviolet light between 100 and 400 nm of wavelength which comprises only 5% in sunlight due to the wide band gap. In addition, rapid recombination of electron-hole pairs reduces the photocatalytic performance. Recently, studies on blackening photocatalysts by laser, thermal, and plasma treatments have been conducted to enhance the absorption of visible light and photocatalytic activity. The disordered structures could yield mid-gap states and vacancies could cause charge carrier trapping. Herein, liquid phase plasma (LPP) is adopted to synthesize Ag-doped black ZnO for the utilization of visible-light. The physical and chemical characteristics of the synthesized photocatalysts are analyzed by SEM/EDS, XRD, XPS and the optical properties of them are investigated using UV/Vis DRS and PL analyses. Lastly, the photocatalytic activity was evaluated using methylene blue as a pollutant.

A Study on the Risk Assessment and Improvement Methods Based on Hydrogen Explosion Accidents of a Power Plant and Water Electrolysis System (발전소 및 수전해 시스템의 수소 폭발 사고 사례 기반 위험성 평가 및 개선 방안 연구)

  • MIN JAE JEON;DAE JIN JANG;MIN CHUL LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.66-74
    • /
    • 2024
  • This study addresses the escalating issue of worldwide hydrogen gas accidents, which has seen a significant increase in occurrences. To comprehensively evaluate the risks associated with hydrogen, a two approach was employed in this study. Firstly, a qualitative risk assessment was conducted using the bow-tie method. Secondly, a quantitative consequence analysis was carried out utilizing the areal locations of hazardous atmospheres (ALOHA) model. The study applied this method to two incidents, the hydrogen explosion accident occurred at the Muskingum River power plant in Ohio, USA, 2007 and the hydrogen storage tank explosion accident occurred at the K Technopark water electrolysis system in Korea, 2019. The results of the risk assessments revealed critical issues such as deterioration of gas pipe, human errors in incident response and the omission of important gas cleaning facility. By analyzing the cause of accidents and assessing risks quantitatively, the effective accident response plans are proposed and the effectiveness is evaluated by comparing the effective distance obtained by ALOHA simulation. Notably, the implementation of these measures led to a significant 54.5% reduction in the risk degree of potential explosions compared to the existing risk levels.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Ultrafiltration and Photocatalyst: 1. Effects of Photocatalyst and Water-back-flushing Condition (세라믹 한외여과 및 광촉매 혼성공정에 의한 고탁도 원수의 고도정수처리: 1. 광촉매 및 물역세척 조건의 영향)

  • Cong, Gao-Si;Park, Jin-Yong
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.127-140
    • /
    • 2011
  • The effects of $TiO_2$ photocatalyst coating bead concentration, water-back-flushing period (FT), and back-flushing time (BT) were investigated in hybrid process of ceramic ultrafiltration and photocatalyst for advanced drinking water treatment in this study. Photocatalyst coating bead concentration was changed in the range of 10~40 g/L, FT in 2~10 min and BT in 6~30 sec. Then, we observed the effects on resistance of membrane fouling $(R_f)$, permeate flux (J) and total permeate volume $(V_{\Upsilon})$ during total filtration time of 180 min. As decreasing photocatalyst coating bead concentration, $R_f$ increased and J decreased. $V_{\Upsilon}$ was the highest value of 8.85 L at 40 g/L of photocatalyst coating bead concentration. At FT change experiment, $R_f$ decreased and J increased as decreasing FT. Then $R_f$ decreased and J increased according to increasing BT at BT change experiment. Because at NBF (no back-flushing) dramatic membrane fouling reduced membrane pore size, turbid and dissolved organic matters ($UV_{254}$ absorbance) could be removed efficiently. Therefore, treatment efficiencies of turbidity and dissolved organic matters were the highest at NBF. Then by cleaning effect of photocatalyst coating bead, the treatment efficiencies of turbidity and dissolved organic matters increased as decreasing FT and increasing BT.

Disinfection Effects of Electrolyzed Water on Strawberry and Quality Changes during Storage (전기분해수 처리에 의한 딸기의 살균 효과 및 저장 중 품질변화)

  • Jeong Jin-Woong;Kim Jong-Hoon;Kwon Ki-Hyun;Park Kee-Jai
    • Food Science and Preservation
    • /
    • v.13 no.3
    • /
    • pp.316-321
    • /
    • 2006
  • Disinfection of electrolyzed water (EW) on strawberry by immersion washing and quality changes during storage at $5^{\circ}\C$ was compared with one immersed in chlorine water and not treated. Total count of strawberry washed with EW by immersion in 10 volumes of EW for 20 min was decreased to about 2 log cycle compared to the untreated And rate of microbial growth during storage was lower than ethers. Decaying ratio in strawberry treated with electrolyzed low-alkalinewater (EW-2) showed lower as of 10% level after 5 days of storage compared) to the untreated and the treated with chlorine water (CW). Hardness in the treatment of EW was not changed significantly until 3 days of storage, after then rather increased. Change in surface color of strawberries was observed; L value in the CW treated and the untreated increased whereas it decreased in the treatment of EW. And color difference(${\Delta}E$) during storage was observed the lowest in the untreated until 3 days of storage. The initial value of residual chlorine in the treatment of EW was at the level of $0.04{\sim}0.06ppm$, and $1{\sim}3$ days later showed almost the equal value to level of $0.02{\sim}0.03ppm$ in all treatments. Sensory characteristic during storage was preferable on strawberry washed with EW (EW-1 and EW-2) to the other treatments.

Prevention of Protein Loss Using A Shield Coating According to Moisture Behavior in Human Hair (수분거동 패턴에 따른 차폐막 설정을 통한 모발단백질 소실방지)

  • Song, Sang-Hun;Lim, Byung Tack;Son, Seong Kil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.1
    • /
    • pp.57-65
    • /
    • 2020
  • To prevent loss of hair protein during hair washing process by water through, a shield coating the pathway of water molecules was studied. Hydrophobic virgin hair, hydrophilic hair, which was damaged only methyleicosanoic acid (18-MEA) on the surface, and a repaired hair re-bound 18-MEA, were prepared and water mass changes by as heat were measured. Results showed that hydrophobic hairs followed bi-exponential function of 39 s and 151 s and other two hairs exhibited fast- and mono-exponential decay with 83 s, reflecting the extraction of water molecules without any resistance at the hydrophobic surface. On the assumption that hydrophobic surface resists an extraction of protein in water during the wash, the protein concentrations were compared from the hair of hydrophobic and hydrophilic surface. The extracted hair proteins were 179 and 148 ㎍/mL from the hair coated with hydrophilic polyethylene glycol (PEG) and hydrophobic polydimethylsiloxane (PDMS), respectively. This study suggested that hydrophobic coating on the hair surface could be used to prevent protein loss in wash, represented by LFM. In conclusion, this research provides some useful information to contribute to the development of hair washing products that can prevent protein loss in the cleaning process by granting hydrophobic coatings.

Study on Influencing Factors of Adhesive Strength for Polymer Coating on Metal Adherend by Dolly Test (돌리테스트로 고분자 코팅층과 금속 피착재의 접착강도 측정시 영향인자에 대한 연구)

  • Baeg, Ju-Hwan;Park, Hyun;Lee, Sung In;Ha, Yungeun;Cho, Young-Rae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.1-8
    • /
    • 2019
  • The demand and importance of adhesives and paint coatings applied to solid surfaces such as metals, ceramics, and plastics are increasing. In this study, the influencing factors on the adhesive strength between the polymer coating and the metal adherend were investigated by Dolly test when the adhesive or the paint coating was applied on the metal adherend. Two-component epoxy adhesive was used as the adhesive, and EH2350, a two-component epoxy paint for anti-corrosion, was used as the paint. Especially, the effect of adherend metals(Al, Fe, STS, Cu, Zn), surface roughness and surface contamination(tap water, salt water) on adhesive strength was studied as influencing factors. The adhesive strength between adhesive and adherend was different when the type of metal adherend was different even when the same adhesive was used. It was found that spray water cleaning was necessary before the paint coating process on the surface of the oxide contaminated adherend with tap water or salt water. As a result of this study, it was confirmed that Dolly test can be widely used in the future to measure adhesive strength between paint coating and adherend.

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Uncertainties of ionic species in snowpit samples determined with ion chromatography system (이온크로마토그래피 시스템을 이용한 눈 시료의 이온성분 측정자료의 불확도 산출)

  • Hong, Sang-Bum;Hur, Soon-Do;Kim, Sun-Mee;Hong, Sungmin;Chung, Ji-Woong;Kang, Namgoo;Kang, Chang-Hee
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.350-363
    • /
    • 2012
  • To determine ionic species in snowpit samples using ion chromatography system, we described the performance of ion chromatography(IC) system, cleaning method of bottle, and interference by filtering procedure. The limit of detection, reproducibilities, and accuracies determined with BCR$^{(R)}$-408 were 0.01-0.26 ${\mu}g$/L, 0.4-17.4%, 4.5-12.0% for cations and 0.02-0.26 ${\mu}g/L$, 0.1-27.6%, 1.3-5.6% for anions, respectively. Lab blank test for sample bottle indicated that $CH_3CO_2{^-}$, $HCO_2{^-}$, and $NH_4{^+}$ can be easily contaminated in the lab environment. The positive interferences of $NO_3{^-}$ were partly attributed to the cleaning method of bottle. The filtering of melted snow sample should be carefully applied because it can positively affect the concentration levels of some ionic species. Finally, this method was applied to measure ionic species in snowpit samples from the upward area near NEEM camp and the uncertainties of measurement data of $F^-$ were also estimated.

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

Optimum Operating Condition for Micro-Filtration Process as a Seawater Desalination Pretreatment (해수담수화 전처리로서 가압식 MF 공정의 최적 운전조건 도출)

  • Kim, Youngmin;Jang, Jung-Woo;Kim, Jin-Ho;Choi, June-Seok;Lee, Sangho;Kim, Sukwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.624-629
    • /
    • 2013
  • The relation between performance maintenance conditions and those cost efficiency was studied to choose an optimum operating condition in the seawater desalination pretreatment system. A hollow fiber microfiltration module, which was developed with domestic technology, was tested with the various operating conditions such as chemically enhanced backwash cycles and design dosages of a cleaning chemical. Transmembrane pressure was measured to investigate membrane fouling status and cleaning degree. In addition, economic analysis was performed to compare water production costs by the operation condition. As a result, The operation mode III, chemically enhanced backwash at once a day with 100 mg/L of sodium hypochlorite (NaOCl) was selected. The concurrent evaluation between membrane filtration performance and its economic analysis will be suitable to choose an efficient optimum condition.