• Title/Summary/Keyword: Water Ballast

Search Result 220, Processing Time 0.022 seconds

Ballast water Treatment using a Multistage Filter (다단 디스크 여과장치를 이용한 선박 밸러스트수 처리)

  • Park, Sang-Ho;Lim, Jae-Dong;Kim, In-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.79-83
    • /
    • 2006
  • Displayed result that handle particle contaminant and hydrospace organism included in number of ballast that is happened in ship using automatic bade washing filter. Reason that remove first contaminant that is included in number of ballast is that heighten processing effect of after processing process. of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The fact that it is easy to attach and detach a several type of screen for getting the expected water quality is another advantage. Filter rotation speed at 1.0rpm is filter resistance 3.0bar and 3.0rpm is filter resistance 2.8bar. Filter out impurities from ballast water over 6.0rpm is filter resistance 26bar and 10rpm is filter resistance 2.5bar. Filtration system removal aquatic organism over $80{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

A Study of Ecotoxicity Test for Byproducts of Ozone in the Ballast Water Treatment System with Ozonation

  • Park, Sung-Jin;Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.741-747
    • /
    • 2011
  • Ecological toxicity testing of the whole-effluent from the ozone ballast water treatment system was conducted as specified in the quality assurance project plans (QAPP). The growth inhibition test with microalgae, acute aquatic toxicity test with the Rotifer reproduction, toxicity test (or population growth) with the Rotifer, survival and growth toxicity test with larval fish and sediment toxicity test with amphipod were carried out to evaluate ecological toxicity on the movile test barge.

Zooplankton Removal in Seawater using UV, Electrolysis and UV+electrolysis Process (UV, 전기분해 및 UV+전기분해 공정을 이용한 해수 중의 동물성 플랑크톤 제거)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.30 no.7
    • /
    • pp.597-604
    • /
    • 2021
  • The International Maritime Organization (IMO) ballast water management agreement (International Convention for the Control and Management of Ship's Ballast Water and Sediments) came into force on September 8, 2017. This study evaluated the disinfection performance of electrolysis, UV treatment, and electrolysis + UV combined, to improve the treatment of zooplankton (size ≥ 50 ㎛), which is expected to strengthen the standards for biodegradation efficiency. Among the methods used, the disinfection time leading to 100% death was in the order: electrolysis > electrolysis + UV > UV process. For the same level of disinfection performance, the amount of electricity required for the electrolysis, UV, and electrolysis + UV processes were 1,300 W.s, 8,400 W.S, and 4,500 W.s, respectively. The combination of electrolysis + UV process for inactivation of zooplankton in ballast water did not show a synergic effect owing to the slow disinfection time and high power consumption.

A Study on the Removal of harmful life from Ballast by Water Pretreatment (선박 밸러스트수의 유해생물 제거를 위한 전처리 연구)

  • Park Sang-Ho;Lim Jae-Dong;Park Sun-Jung;Kim In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.221-226
    • /
    • 2006
  • This study is about backwash condition and membrane fouling at continuous filtration process in ballast water treatment. Displayed result that handle particle contaminant and hydrospace organism included a number of ballast that is happened in ship using automatic back washing filter. Reason that removes first contaminant that is included in number of ballast is that heighten processing effect of after processing process of the filter. Another advantage is to drop off the solids with controlling revolution of drum screen in pretreatment filtration process. The capacity of pilot plant was $10m^3/h$. The result of the test, Backwash cycle time and duration time and a signification effect on the efficiency of system and backwash Backwash duration time was determined to be fixed in 6 seconds of the system with more than 95% removal rate, It needed 1hour backwash frequency. Filtration system removal aquatic organism over $70{\mu}m$ in ballast water. This study shows that the filtration treatment system has a potential for the treatment of ballast water.

  • PDF

A Study on the Industrial Competitiveness of Ballast Water Management System in Compliance with the International Maritime Organization Ballast Water Management Convention in Korea (우리나라 선박평형수처리시스템(BWMS) 산업의 경쟁력 분석에 관한 연구)

  • Park, Han-Seon;Kim, Bo-Ram;Lee, Jeong-Seok;Chung, Haeng-Un
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.483-492
    • /
    • 2020
  • In this study, we compared and analyzed the Revealed Comparative Advantage (RCA) and Trade Specialization Index (TSI) based on ballast water management systems (BWMS) trade data, which are related to the International Maritime Organization (IMO) Ballast Water Management Convention to suggest the current status of Korea's industrial competitiveness and suggest future development directions for the BWMS industry. As international interest in eco-friendly vessels is expanding, the IMO is engaged in dramatic discussions and agreement-making related to marine emissions of pollutants from ships. IMO member states that must implement this convention are striving to develop technology and secure industrial competitiveness as major industries in the eco-friendly shipping sector, with the BWMS industry experiencing a high market entry barrier and the possibility of the leading market entrants gaining leadership. The Republic of Korea accounts for 17 (approximately 38 %) of the 45 BWMS that received final approval as of October 2019. Based on trade data relating to product codes HS842219, HS84212, and HS89, the RCA index and TSI were calculated and compared. The findings revealed that the Republic of Korea has relative inferiority compared to countries such as Germany and Denmark. Despite this, Korea's favorable industrial environment, which includes several IMO-approved BWMS technologies and the possession of domestic certification institutions, is likely to strengthen its competitiveness in the BWMS market.

Degradation and Neutralization of Total Residual Oxidant (TRO) in the Treated Ballast Water by Ozonation

  • Park, Sung-Jin;Bin, Jung-In;Lee, Eon-Sung;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.399-406
    • /
    • 2010
  • The aims of this study are to provide data on the ozone dosage control system and TRO sensor performance, to assess the performance of the degradation of total residual oxidant (TRO) neutralizer and to provide data on degradation rates of TRO in the ballast tanks, following treatment by the Ozone BWTS. This study includes the results of an evaluation of the TRO neutralizer, which was tested on the test barge. Accordingly, it has undertaken the evaluation of TRO degradation rates following treatment by the Ozone BWTS.

Design and Fabrication of a Ballast Water Treatment System Using UV Lamps (자외선램프를 이용한 선박평형수 처리시스템의 설계 및 제작)

  • Pyo, Tae-Sung;Cheon, Sang-Gyu;Park, Dae-Won;Choi, Sung-Kuk;Kim, Seong-Yeon;Kil, Gyung-Suk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.952-958
    • /
    • 2009
  • The International Maritime Organization (IMO) has adopted the ballast water management convention at a diplomatic conference in early 2004 that all ships should be equipped with a treatment system from 2010 gradually. In this paper, the disinfection characteristic of ultra-violet (UV) rays was studied and a ballast water treatment system (BWTS) which can treat $50m^3$/h sea water was manufactured. The system consists of a disinfection chamber with six 3.5 kW UV lamps which are operated by magnetic ballasts, a programmable logic controller (PLC) and set of pipe lines. The biological disinfection efficacy of the prototype BWTS was evaluated following the IMO rules using zooplankton such as Artemia and Rotifer species for the size over $50{\mu}m$, and phytoplankton such as Tetraselmis and Thalassiosira species for the size between 10 to $50{\mu}m$. From the experimental results, the disinfection efficacy was 99.99 % that meets the IMO requirement. However, more studies on an energy saving system are needed because the consumption power of the prototype system is as high as over 21 kWh for $50m^3$/h.

Consideration of Species-specific Risk Assessment Method of Ballast Water (선박평형수 종별 특이성 위해도 평가 방법에 관한 고찰)

  • Lee, S.G.;Kang, W.S.;Kim, E.C.;Shin, K.S.;Oh, J.H.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.14 no.4
    • /
    • pp.293-300
    • /
    • 2011
  • Many countries of the world, including IMO, has noticed that foreign marine hazardous organisms, which were introduced by ballast water, have disturbed the marine ecosystem of its own nation, and posed a serious threat to human health and the value of environment and economy. Therefore, IMO has tried to manage the introduced species by assessing the risk of ballast water, and suggested three risk assessment methods, such as environmental matching risk assessment, speciesbiogeographical risk assessment, and species-specific risk assessment. In this thesis, species-specific risk assessment method was considered, and a risk assessment program established by applying it was described.

A Study on the Optimization of Ballast Water Treatment System for Scale-up (선박평형수 처리장치의 Scale-up을 위한 조건 최적화 연구)

  • Kang, Ahyoung;Song, Ju Yeong
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.630-635
    • /
    • 2016
  • In the prior work, we studied a ballast water treatment apparatus, which is secondary pollution free by using physical treatment of shear stress. The principle of this apparatus is smashing various microorganisms by shear stress generated between stationary outer cylinder and revolving inner cylinder. Because of various magnitude of shear stress according to the inner cylinder surface type and revolution speed, an appropriate surface type and optimum revolution speed should be studied by consecutive experiment to determine the reference data for commercial apparatus. Through a comparative study of disk type and cylinder type of ballast water treatment apparatus, cylinder type is turned out to be superb to disk type. In this study, we studied to determine the superior collaboration of cylinder type, groove type and knurling type of inner cylinder to non patterned outer cylinder, and to optimize the revolution speed and flow rate according to the gap between inner cylinder and outer cylinder. As a result, we could get perfect sterilization effect at groove type under the conditions of 250 mL/min of flow rate at 8,000 rpm and 500 mL/min of flow rate at 10,000 rpm respectively.

Feasibility Study on Potassium Iodide (KI) Sensor for Measuring Total Resiudual Oxidant in Ballast Water (선박 평형수 내 총 잔류 산화물(Total Residual Oxidant) 분석을 위한 Potassium Iodide (KI) Sensor 적용가능성 평가)

  • Kwon, Jae Hyeong;Lim, Heon Jin;Lee, Gwan Ho;Lee, Hai Don;Kim, Dae Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.11
    • /
    • pp.596-602
    • /
    • 2016
  • Potassium iodide (KI) TRO sensor for measuring total residual oxidant which is an index for disinfection and neutralization in ballast water has been constructed. The results of UV absorption wavelength and absorbance test in various TRO concentrations show high linear correlation ($r^2=0.9825$) at 350 nm wavelengths and it can be possible to visualize numerical value of TRO concentration (0.1~7.0 mg/L). The result of comparison test according to TRO concentration between the KI based TRO sensor system and the DPD based TRO sensor system showed identical trend. Overall results indicated that the KI TRO sensing system could be applied for continuous TRO concentration measurement in ballast water treatment system.