• 제목/요약/키워드: Wastewater treatment effluent

검색결과 676건 처리시간 0.027초

젖소 착유세정폐수의 효율적인 정화처리를 위한 기초연구 (Preliminary Studies for Efficient Treatment of Wastewater Milking Parlor in Livestock Farm)

  • 장영호;이수문;김웅수;강진영
    • 한국물환경학회지
    • /
    • 제36권6호
    • /
    • pp.500-507
    • /
    • 2020
  • This study examined the wastewater at a livestock farm, and found that the dairy wastewater from the milking parlor had a lower concentration than the piggery wastewater, and that it was produced at a rate under 1.3 ㎥/day in a single farmhouse. The amount of dairy wastewater was determined based on the performance of the milking machine, the maintenance method of the milking parlor, and the amount of milk production allocated for each farmhouse, not by the area. The results confirmed that both dairy wastewater treatment processes, specifically those using Hanged Bio-Compactor (HBC) and Sequencing Batch Reactor (SBR), can fully satisfy the water quality standards of discharge. The dairy wastewater has a lower amount and concentration than piggery wastewater, meaning it is less valuable as liquid fertilizer, but it can be easily degraded using the conventional activated sludge process in a public sewage treatment plant. Therefore, discharging the dairy wastewater after individual treatment was expected to be a more reasonable method than consigning it to the centralized wastewater treatment plant. The effluent after the SBR process showed a lower degree of color than the HBC effluent, which was attributed to biological adsorption. In the case of the milking parlor in the livestock farm, the concentrations of the effluents obtained after HBC and SBR treatments both satisfied water quality standards for the discharge of public livestock wastewater treatment plants at 99% confidence intervals, and the concentrations of total nitrogen and phosphorous in untreated wastewater were even lower than the water quality standards of discharge. Therefore, we need to discuss strengthening the water quality standards to reduce environmental pollution.

실용 가능한 최적처리기술에 근거한 산업폐수 배출허용기준 설정 연구 - 펄프.종이 및 종이제품 제조시설 적용 사례 (Study on Establishment of the Industrial Wastewater Effluent Limitations Based on Best Practicable Control Technology Currently Available - Case Study for the Pulp, Paper and Paper Board Manufacturing)

  • 김재훈;신진수;이철구;이정영;이영선;유순주
    • 한국물환경학회지
    • /
    • 제28권4호
    • /
    • pp.608-614
    • /
    • 2012
  • The effluent limitation of industrial wastewater is based on uniform regulatory criteria for effluent discharge facilities of all in Korea. But, an individual effluent limitation on each effluent discharge facility is widely applicable for regulation of industrial wastewater in US.EPA. To decide an individual effluent limitation, TBEL (Technology-based effluent limitation) and WQBEL (Water quality-based effluent limitation) are used. TBEL is based on the capability of a treatment technology to reduce the pollutants. WQBEL is based on ambient water quality standards. In this study, TBEL were derived for the pulp, paper and paper board manufacturing based on best practicable control technology currently available. It was suggested that effluent limitations were $BOD_5$ 4.7 mg/L, $COD_{Mn}$ 44.3 mg/L, SS 13.2 mg/L, TN 1.4 mg/L, TP 0.15 mg/L and best practicable control technology currently available (BPT) was neutralization, activated sludge treatment and coagulation and sedimentation for the pulp, paper and paper board manufacturing.

CFD와 PIV test를 통한 원형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of circular secondary clarifier using CFD and PIV test)

  • 최영균;배강형
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.73-81
    • /
    • 2014
  • One-dimensional flux theory (1DFT) is conventionally used for design of secondary clarifier of wastewater treatment plant. However, the 1DFT cannot describe turbulence, density current, shape parameters of the clarifier. In this study, we optimized the configurations of influent guide baffle and effluent baffle through the simulation using computational fluid dynamics (CFD) and its verification by particle image velocity (PIV) test. The energy dissipating inlet (EDI) without influent guide baffle ($0^{\circ}$) showed the best efficiency for minimizing downward velocity under the center well of the clarifier. The lowest velocity distribution around the effluent weir region could be obtained with the McKinney baffle (EB-2). The performances of the influent and effluent baffles were clearly verified by PIV test results.

Phanerochaete chrysosporium PSBL-1을 이용한 축산폐수와 하수의 연계처리 (Combined Treatment of Livestock Wastewater with Sewage Using Phanerochaete chrysosporium PSBL-1)

  • 이순영;조홍식;원찬희
    • 대한환경공학회지
    • /
    • 제28권3호
    • /
    • pp.286-291
    • /
    • 2006
  • 본 연구에서는 축산폐수와 하수의 연계처리 가능성을 연구하였다 축산폐수와 하수를 2:1로 혼합하고 응집제인 BF02와 응집보조제인 양이온 polymer인 C-210EL를 각각 2 mL, 100 mL씩 주입시 SS 97.6%, T-P 95%로 최적 제거효율을 보였다. Phanerochaete chrysosporium PSBL-1의 처리 특성을 살펴보기 위해서 전처리수를 축산폐수 원수에 대해 10배 희석되도록 하수와 혼합($\fallingdotseq$전처리수:하수=3:17)하였다. 이렇게 혼합된 폐수의 NBDCOD, $NH_3-N$, T-N의 제거율은 pH가 증가할수록 증가하였다. 즉, T-N 농도는 pH 6.7(5일 경과시), pH 8.0(3일 경과시), pH 10.0(1일 경과시)에서 각각 35 mg/L, 51 mg/L, 33 mg/L으로 축산폐수공공처리시설의 방류수허용기준 60 mg/L을 만족하였다. 또한 모든 pH(1일 경과시)에서 $COD_{Mn}$의 방류수허용기준 40 mg/L을 만족했다. V.A.(veratryl alcohol) 첨가시 V.A.를 첨가하지 않은 조건보다 유출수의 유기물 및 질소농도가 높게 측정되었다. $COD_{Mn}$은 C/N비(3:1)를 조절하지 않은 경우 1일 이후, T-N은 C/N비를 $4{\sim}6$으로 조절한 경우 2일 후에 축산폐수공공처리시설 방류수수질기준을 만족하였다.

특정제조업 폐수처리시설에 대한 신뢰성 평가 (Reliability Assessment of Industrial Wastewater Treatment Plant)

  • 양형재;김재훈;이성종
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.1-9
    • /
    • 2007
  • A wastewater treatment plant, operating process is physico-chemical/biological activated sludge attached sand filtration, was selected to evaluate effluent quality and pollutants removal efficiencies consideration for deriving the technology-based effluent limitation for petroleum refining industry discharge. The results of influent and effluent analysis were as follows: Average effluent quality were 0.076mg/l of copper, 0.084mg/l of lead, 0.036mg/l of zinc, 0.005mg/l of nickel and 0.004mg/l of cadmium, and the range of coefficient of reliability from 0.007 of copper to 1.0 of lead. Also, 95% of reliability, 0.112, 0.15, 0.063, 0.015 and 0.009mg/l, respectively, were remarkably lower than their effluent limitations. And to reach 95% reliability of effluent limitation at cleanness area, designed effluent quality of copper, lead, zinc and cadmium should be 0.268, 0.099, 0.526 and 0.008mg/l, respectively.

하·폐수처리시설 방류수내 유기물질 및 NOD 분포 특성 (Distribution of Organic Matter and Nitrogenous Oxygen Demand in Effluent of Sewage and Wastewater Treatment Plants)

  • 김호섭;김석규
    • 한국물환경학회지
    • /
    • 제37권1호
    • /
    • pp.20-31
    • /
    • 2021
  • In this study, an analysis of the characteristics of organic matter and nitrogenous oxygen demand (NOD) of 17 sewage effluent and wastewater treatments was conducted. High CODMn and carbonaceous biological oxygen demand (CBOD) concentrations were observed in the livestock treatment plants (LTP), wastewater treatment plants(WTP), and night soil treatment plants (NTP), but the highest NOD concentration and contribution rates of NOD to BOD5 were found in sewage treatment plants (STP). There was no significant difference in the CBOD/CODMn ratio for each of the six pollution source groups, but the LTPs, WTPs, and NTPs all showed relatively high CODMn concentrations in their effluent samples, indicating that they are facilities which discharge large amounts of refractory organic matter. The seasonal change of NOD in all facilities' effluent was found to be larger than the seasonal change of CBOD, and data results also revealed an elevation of NOD and NH3-N concentration from December to February, when the water temperature was low. There was no significant difference in NH3-N concentration in relation to pollution source group (p=0.08, one-way ANOVA), but the STP, which had a high NOD contribution rate to BOD5 of 48%, showed a high correlation between BOD5 and NOD (r2=0.95, p<0.0001). These results suggest that the effect of NOD on BOD5 is an important factor to be considered when analyzing STP effluent.

MS Excel 시뮬레이터(PKES)를 이용한 하수처리장 유출수 및 온실가스 모델링 (Modelling of effluent and GHGs for wastewater treatment plants using by MS Excel simulator(PKES))

  • 빈정인;이병헌
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.735-745
    • /
    • 2014
  • This paper presents PKES(PuKyung -Excel based Simulator) for WWTPs(wastewater treatment plants) by using MS Excel and VBA(Visual Basic for Application). PKES is a user-friendly simulator for the design and optimization of the whole plant including biological and physico-chemical processes for the wastewater and sludge treatment. PKES calculates the performance under steady or dynamic state and allows changing the mathematical model by the user. Mathematical model implemented in PKES is a improved integration model based on ASM2d and ADM1 for simulation of AS(activated sludge) and AD(anaerobic digestion). Gaseous components of $N_2$, $N_2O$, $CO_2$ and $CH_4$ are added for estimation of GHGs(greenhouse gases) emission. The simulation results for comparison between PKES and Aquasim(EAWAG) showed about the same effluent concentrations. As a result of verification using by measured data of BOD, TSS, TN and TP for 2 years of operation, calculated effluent concentrations were similar to measured effluent concentrations. The values of average RMSE(root mean square error) were 1.9, 0.8, 1.6 and 0.2 mg/L for BOD, TSS, TN and TP, respectively. Total GHGs emission of WWTP calculated by PKES was 138.5 ton-$CO_2$/day and GHGs emissions of $N_2O$, $CO_2$ and $CH_4$ were calculated at 21.7, 28.9 and 87.9 ton-$CO_2$/day, respectively. GHGs emission of activated sludge was 32.5 % and that of anaerobic digestion was 67.5 %.

Estogenic and Dioxin-like Activity of Influent and Effluent of the Industrial Wastewater Treatment Plant

  • Oh, Seung-Min;Kim, Gi-Sur;Kim, Soung-Ho;Kim, Yun-Hee;Chung, Kyu-Hyuck
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2002년도 추계국제학술대회
    • /
    • pp.166-166
    • /
    • 2002
  • The response of environmental pollutants can be detected bioanalytically focusing on the source and matrices of concern. Cell culture bioassays are rapid and inexpensive, and thus have great potential for determination of environmental pollution. We have examined the estrogenic and dioxin-like activites of industrial wastewater using E-screen assay and EROD microbioassay. Influent and effluent wastewater were collected from four different industrial wastewater treatment plants, such as cosmetics, paints, textile producing and metal coating plant, and extracted using solid-phase extraction with Oasis@HLB plus cartridge. Pollutants adsorbed to the cartridge were eluted with MTBE. MCF-7 cells were treated with extracts showed various estrogenic potential. The textile wastewater showed strong estrogenic activity and the others showed weak estrogenic activity, No effect was observed in the wastewater from paints producing plant. All extracts showed CYPIA inducing effects, indicating these samples contain dioxin-like chemicals. Bioanalytical results of effluents compared with influents could give us information about the incomplete wastewater treatment and biological potency caused by pollutants. [Supported by a Grant from the Korea Science and Engineering Foundation]

  • PDF

화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구 (A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater)

  • 박선구;고오석;신대윤
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동 (Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents)

  • 한지희;손진식
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.