• Title/Summary/Keyword: Wastewater reclamation

Search Result 66, Processing Time 0.028 seconds

A study on the Reclamation and Reuse of Milk Manufacturing Wastewater (유가공폐수 처리수의 재이용에 관한 연구)

  • 곽필재;우달식;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.111-119
    • /
    • 1997
  • We met the continued population growth, contamination of both surface and groundwaters, deficiency of water resources, and increase of water demand. Wastewater reclamation and reusing system are important facilities in water resources planning aspect. The required water quality for reclamed wastewater varies with each application. This study was conducted to examine the possibilities of the wastewater reclamation and reusing on milk manufacturing wastewater. Biofiltration could reduce the COD$_{Cr}$, NH$_{3}$-N. Turbidty was reduced highly by coagulation. In conclusion, we identified the possibilities of wastewater reclamation and reusing on milk manufacturing wastewater's by biological activated carbon filter.

  • PDF

Trends and Directions in the Development of Wastewater Reclamation and Reuse Technology for Alternative Water Resources (대체수자원 확보를 위한 하수 재이용 기술 동향과 발전방향)

  • Cho, Il Hyoung;Lee, Si Jin;Kim, Ji Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.1
    • /
    • pp.127-137
    • /
    • 2013
  • Reuse of wastewater will intensify in the coming decades due to water shortage, the change of climatic conditions, the need for industrial and agricultural use and the necessity of improving health and environmental conditions for the growing population. This paper considers (a) the status and trends of wastewater reuse and reclamation in the world, (b) case studies of wastewater reuse projects, (c) analysis of technology level, (d) forecast of global market, and (e) the future views and directions in development of wastewater reuse technologies. Based on the available documented literature, this paper provides a review assessment of the current status of the wastewater treatment processes including potential applications for reuse. Key challenges for both wastewater treatment and reuse are also discussed in the paper and include recommendations, e.g. cost, effluent water quality, energy use and technical solutions, for future developments.

Study on Installation Capacities of Wastewater Reclamation and Reusing System Applying to Contact Aeration Process using Cost-benefit Analysis (경제성분석을 이용한 접촉폭기방식 중수도의 설치규모분석에 관한 연구)

  • Nam, Young-Woo;Park, Tae-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.11
    • /
    • pp.1945-1954
    • /
    • 2000
  • This study provides economical installation capacities for wastewater reclamation and reusing system in 7 areas of South Korea applying to contact aeration process using NPV(net present value) model based on cost-benefit. First. considering only private benefits. economical installation capacities for wastewater reclamation and reusing system applying to contact aeration process in household use were more than $500m^3/day$ in Pusan. $1,000m^3/day$ in Taegu. $2,000m^3/day$ in Kwangju. However. installation capacities in Seoul. Inchen, Taejon, and Ulsan were not optimal for $3,000m^3/day$. Therefore, supply ways of wastewater reclamation and reusing system in household use in the latter areas were more optimal local recirculation system than individual recirculation system. Economical installation capacities for wastewater reclamation and reusing system in business use were more than $100m^3/day$ in Seoul. Pusan. and Kwangju and which were $300m^3/day$ in Taegu, Inchen, Taejon, and Ulsan. Economical installation capacities for wastewater reclamation and reusing system in commercial use were more than $100m^3/day$ in Seoul, Pusan, Taegu, Kwangju, Taejon, and Ulsan, and which were $300m^3/day$ in Inchen. Second, considering only social benefits. economical installation capacity for wastewater reclamation and reusing system applying to contact aeration process was more than $100m^3/day$.

  • PDF

A Study by Proposal of Efficiency Increase for a Full-scale Wastewater Reclamation Facility using a Biofilter Packed with Granular Sulfur (하수처리수 재이용을 위한 실규모 입상황 생물막여과 시설의 효율증대 방안에 관한 연구)

  • Moon, Jin-Young;Hwang, Yong-Woo;Baek, Seung-Ryun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.73-83
    • /
    • 2010
  • This study was performed to increase the removal efficiency of the biofilter packed with granular sulfur in municipal wastewater reclamation facility. Constituent units were influent water tank, denitrification tank, BOD reduction tank and outlet. And, the major operation factor is a biofilter packed with submerged granular sulfur. Actual wastewater and synthetic wastewater were used as influent wastewater. Experimental condition was divided into two phases according to the amount of a phosphorus coagulant. Total phosphorus removal efficiency was insignificant at mode I that phosphorus coagulant was not injected. The average influent and effluent total phosphorus concentrations at mode II were 0.5 ~ 1.0 mg/L and 0.27 mg/L, respectively. As for COD and BOD effluent concentrations, COD was 3.0 mg/L and BOD was 1.0 mg/L. Additionally, nitrogen removal rates were high at low influent DO concentration. In conclusion, a new process, biofilter packed with granular sulfur is expected to treat high-rate nitrogen wastewater and expected to be utilized as an alternative of technological innovation for the nitrogen treatment.

Implementation of C-HMI based Real-time Control and Monitoring for Remote Wastewater Reclamation and Reusing System (C-HMI 기반의 원격지 중수도 설비 실시간 제어와 모니터링 구현)

  • Lee, Un-Seon;Park, Man-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.717-722
    • /
    • 2013
  • The wastewater reclamation and reusing system has been rising as an alternative of water resource exhaustion that the whole world is experiencing. In order to be able to bring about improvement of the existing wastewater reclamation and reusing system, this research has developed of Conversion-Human Machine Interaction (C-HMI) based real-time control and monitoring system such as a sensor module and gate module, web monitoring system. This system was communication almost-error-free in various environment and situation. As a result, we have achieved our goal that has to doing work correctly as a sensor and gateway module that communication error is less than 0.2% throughout the embodied system and add that it can be easily controled and configured as an interface equipment to a complex sensor of water quality. According to this, the construction of a database capable of analyzing and assessing collection, storage and various elements of reliable water quality and flow rate data can be possible.

A Study on the Application of Pre-Chemical Treatment on the Decentralized Domestic Wastewater Reclamation System (도시의 분산형 생활오수 재생시스템에 화학적 전처리공정도입에 관한 연구)

  • Lee, Sang-Woo;Park, Young-Mi;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.115-121
    • /
    • 2006
  • The purpose of this study was to investigate applicability of pretreatment on the existing biological treatment for domestic wastewater reclamation. From Jar Tests, it was found that optimum dosage of coagulant was PAC 0.5mg/L and $FeCl_3$ 180mg/L for urban sewage. In this study, PAC 0.5mg/L was selected considering sludge production and the amount of coagulant required. In a continuous experiment performed with combining chemical coagulation and biological treatment, a considerable removal efficency was obtained in term of BOD, SS, T-N, T-P and ABS. When the raw sewage was supplied into the pre-chamical treatment facility, the removal of BOD and SS was 48.3% and 81.1%. However T-N removal was very low which means T-N consists of $NH_3-N$ mostly. T-P was almost completely recluced by the chemical addition. The effluent BOD & SS was 57~76 and 21~43mg/L, which could reduce the size of biological treatment facility. From the cost estimation pre-chemical treatment could save around half of the area required for biological treatment with post ceagulation.

Enhancement of Discfilter Removal Efficiency for Small-scale Wastewater Reclamation (소규모 하수 재이용을 위한 디스크필터의 처리 효율 증진에 관한 연구)

  • Choi, Nag-Choul;Kim, Bong-Ju;Park, Seong-Yong;Park, Hyeong-U;Lee, Sung-Jae;Park, Cheon-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.66-72
    • /
    • 2015
  • The aim of this study was to enhance of the Discfilter process (maximum treatment capacity - 500 ton/day) removal efficiency for small-scale wastewater reclamation under various influent wastewater conditions (with / without coagulation process, coagulant content and temperature). The result of chemical resistance test for fiber filter in the Discfilter that weight loss was obtained with 0.535% under pH 3, 0.092% under pH 9 and 0.028% under 10% NaClO. The removal efficiency test of Discfilter process on the with / without coagulation process showed that with coagulation process condition was occurred CODMn of 42.26 ± 0.61, BOD5 of 88.72 ± 0.44, T-P of 84.67 ± 0.72 and SS of 90.58 ± 0.61. The removal efficiency of Discfilter process on the coagulant content (4.5, 5.0 and 5.0 mL/min) and temperature (< 10℃, 10℃~ 20℃ and > 20℃) conditions were increased as coagulant content and temperature increased. This study demonstrated the potential application of Discfilter process for small-scale wastewater reclamation.

Fouling and cleaning of reverse osmosis membrane applied to membrane bioreactor effluent treating textile wastewater

  • Srisukphun, Thirdpong;Chiemchaisri, Chart;Chiemchaisri, Wilai;Thanuttamavong, Monthon
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • Membrane bioreactor (MBR) and reverse osmosis (RO) membrane system was applied to the treatment and reclamation of textile wastewater in Thailand. An experiment was carried out to determine the fouling behavior and effect of anti-scalant and biocide addition to flux decline and its recovery through chemical cleaning. The RO unit was operated for one month after which the fouled membranes were cleaned by sequential chemical cleaning method. RO flux was found rapidly declined during initial period and only slightly decreased further in long-term operation. The main foulants were organic compounds and thus sequential cleaning using alkaline solution followed by acid solution was found to be the most effective method. The provision of anti-scalant and biocide in feed-water could not prevent deposition of foulant on the membrane surface but helped improving the membrane cleaning efficiencies.