• Title/Summary/Keyword: Wastewater effluent

Search Result 878, Processing Time 0.026 seconds

The Effect of the Reaction Time Increases of Microbubbles with Catalyst on the Nitrogen Reduction of Livestock Wastewater (가축분뇨의 마이크로버블과 촉매와의 반응 시간 증가에 따라 질소 제거에 미치는 영향)

  • Jang, Jae Kyung;Sung, Je Hoon;Kang, Youn Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.578-582
    • /
    • 2015
  • It was investigated whether the removal of nitrogen ions included livestock wastewater were increased by increasing the reaction time of livestock wastewater and microbubbles with catalyst. For this study, the nitrogen reduction system using microbubbles with catalyst was used. The two reactors were consecutively arranged, and the second reactor (Step 2) was located to next the first reactor (Step 1). Each reactor was reacted for 2 hours and air or oxygen as oxidant was fed into the reactor during operation before microbubble device. When oxygen was used, ammonia nitrogen was removed each 18.3% and 52.8% during 2 (only step 1) and 4 (step 1 and step 2) hours reactions. This value was higher than that of when air was fed. When oxygen was used, the longer the reaction time, the ammonia nitrogen removal was higher. The longer the reaction time, the higher the nitrite and nitrate was also removed such as ammonia nitrogen. Also this system was examined whether organic matter removal is effective. The total chemical oxygen demand (TCOD) removal was higher than the soluble chemical oxygen demand (SCOD). Some materials among causing substances COD were difficult to decompose biologically. Therefore, it means that it will be easy to operate the biological processes following step and reduce the concentration of organic contaminants in effluent.

Removal of Nitrogen Using by SOD Process in the Industrial Wastewater Containing Fluoride and Nitrogen from the Zirconium Aolly Tubing Production Factory of the Nuclear Industry (원자력산업 지르코늄합금 튜브 생산공장에서 배출되는 불소.질소 함유 폐수의 황산화탈질을 이용한 질소처리)

  • Cho, Nam-Chan;Moon, Jong-Han;Ku, Sang-Hyun;Noh, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.855-859
    • /
    • 2011
  • The main pollutants from zirconium alloy tubing manufacturing process in nuclear industry are nitrate ($NO_3-N$) and fluoride (F-)Nitric acid, and hydrofluoric acid is used for acid pickling. The process for the removal of nitrate and fluoride is composed of 1st chemical coagulation, SOD (Sulfur Oxidation Denitrification) process using sulfur-oxidizing denitrification, and 2nd chemical coagulation. The characteristic of the wastewater treatment is an application of SOD process. The SOD Process is highly received attention because it is significantly different from existing processes for sulfur denitrification. A JSC (JeonTech-Sulfur- Calcium) Pellet is unification of sulfur and alkalinity material. According to result of SOD process in wastewater treatment plant, the removal efficiency of T-N was over 91% and the average concentration of T-N from influent was 147.55 mg T-N/L and that from effluent was 12.72 mg T-N/L. Therefore, SOD process is a useful to remove nitrogen from inorganic industrial wastewater and a new development of microbial activator was shown to be stable for activation of autotrophic bacteria.

Petrochemical effluent treatment using natural coagulants and an aerobic biofilter

  • Bandala, Erick R.;Tiro, Juan Bernardo;Lujan, Mariana;Camargo, Francisco J.;Sanchez-Salas, Jose Luis;Reyna, Silvia;Moeller, Gabriela;Torres, Luis G.
    • Advances in environmental research
    • /
    • v.2 no.3
    • /
    • pp.229-243
    • /
    • 2013
  • Coagulation-flocculation (CF) was tested coupled with an aerobic biofilter to reduce total petroleum hydrocarbon (TPHs) concentration and toxicity from petrochemical wastewater. The efficiency of the process was followed using turbidity and chemical oxygen demand (COD). The biofilter was packed with a basaltic waste (tezontle) and inoculated with a bacterial consortium. Toxicity test were carried out using Lactuca sativa var. capitata seeds. Best results for turbidity removal were obtained using alum. Considerable turbidity removal was obtained when using Opuntia spp. COD removal with alum was 25%, for Opuntia powder it was 36%. The application of the biofilter allowed the removal of 70% of the remaining TPHs after 30 days with a biodegradation rate (BDR) value 47 $mgL^{-1}d^{-1}$. COD removal was slightly higher with BDR value 63 $mgL^{-1}d^{-1}$. TPH kinetics allowed a degradation rate constant equal to $4.05{\times}10^{-2}d^{-1}$. COD removal showed similar trend with $k=4.23{\times}10^{-2}d^{-1}$. Toxicity reduction was also successfully achieved by the combined treatment process.

활성탄 담체가 포함된 Jet-Loop Reactor를 이용한 종합염색폐수처리

  • Park, Jong-Tak;Lee, Gil-Ho;Ryu, Won-Ryul;Jo, Mu-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.406-409
    • /
    • 2000
  • For the effective treatment of dye-processing wastewater, JLR(Jet-Loop Reactor) with active carbon supports were investigated. BOD removal efficiency was found as 99% when influent BOD concentration of dye-processing wastewater was 400 mg/L. $COD_{Mn}$ of effluent removal efficiencies were found as 86${\sim}$ 89% when these of activated sludge reactor were 62${\sim}$72%. Also, color removal efficiencies were found as 84${\sim}$87% when these of activated sludge reactor were 72%${\sim}$77%. After JLR with active carbon supports had been used, all of the $COD_{Mn}$, $COD_{Cr}$ and color removal efficiencies Increased when chemical precipitation was done. Consequently, JLR with active carbon supports was proved to be more excellent than the activated sludge reactor.

  • PDF

Internal Short-circuiting Estimation in Clearwell : Part A. Improving T10/T Using Intra Basin and Diffuser Wall by Applying ISEM to Field (정수지 내부 단락류 발생 평가 : Part A. 정수장 내부 단락류 분석을 통한 장폭비와 형태가 T10/T 값에 미치는 영향 연구)

  • Shin, Eunher;Lee, Seungjae;Kim, Sunghoon;Park, Heekyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.105-112
    • /
    • 2008
  • Disinfection is a basic and effective microorganism inactivation method and historically contributed a decrease in waterborne diseases. To guarantee the disinfection ability, improving T in CT value is important. Many indexes are used to estimate the hydraulic efficiency, however, these are black-box analysis. Therefore it is need to develope new estimation method. In this study, internal short-circuiting estimation method (ISEM) is developed using CFD and we inquire into the factor which causes increase of $T_{10}/T$ value as LW ratio increases. And the effect of shape on the relation of LW ratio and $T_{10}/T$ is analyzed. As LW ratio increases, internal short-circuiting index (ISI) of influent and effluent zone is rapidly reduced and recirculation and dead zone are reduced in channel zone. Therefore, as the $T_{10}/T$ value converges maximum value, ISI curve is changed from "V" shape to "U" shape and hydraulic efficiency is improved especially in downstream portion of clearwell. The less the shape ratio(width/length of clearwell) is the less the $T_{10}/T$ value is at a same LW ratio because the portion of turning zone increases as shape ration decreases, therefore more boundary separation is generated.

Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Estimation of damage area on membrane surface by application of fluorescent particles as a surrogate (형광입자를 이용한 분리막 표면 검측과 손상 면적 추정 오차에 대한 연구)

  • Choi, Yunkyeong;Kim, Choah;Kim, Heejun;Cho, Jinwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.171-179
    • /
    • 2014
  • In this study, a novel method was proposed to test the integrity of water treatment system specifically equipped with membrane filtration process. We applied the silica particles coated with a fluorescent agent (rhodamine B isothiocyanate) as a surrogate to detect a membrane process integrity and evaluate the reliability of effluent quality in the system. Additionally, a series of experiments was conducted to evaluate the sensitivity of the method through the laboratory scale experiment. The laboratory scale experiments showed that the feasibility of application of proposed method to detect a breach or damaged part on the membrane surface. However, the sensitivity on predicting the area of a breach was significantly influenced by the testing conditions such as a concentration of surrogate, filtration flux, and detection time. The lowest error of predicting the area of breach was 3.5% at the testing condition of surrogate concentration of 80 mg/L injected with flux of $20L/m^2/hr$ for 10 minutes of detection time for the breach having the actual area of $7.069mm^2$. However, the error of estimation was increased at the small breach with area less than $0.785mm^2$. A future study will be conducted to estimate a damaged area with more accuracy and precision.

Economic Evaluation of Integrated Operation & Management through Operation Performance Analysis of Sewage Facilities (하수도시설 통합운영 성과분석을 통한 통합운영관리의 경제성 평가)

  • Shin, Jungsub;Chung, Seokhyun;Cho, Byoungog;Lee, Kwanhyung;Kang, Seonhong;Kim, Yongdae;Yoon, Joonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • For economic evaluation of integrated operation to sewage facilities, benefit-cost analysis was performed to watershed sewage works project in 7 watershed areas, 156 facilities. In this study, the cost before and after integrated operation was compared and benefits are calculated from the reduction of operators, increasement treated pollution loads, reduction cost through operation convenience, reduction water consumption through effluent reuse, and improvement of life benefit. The result showed that cost was 8,500million won and benefit was 16,747million won, so benefit was 49% higher than cost. B/C analysis result showed that B/C ratio was 1.97 and it is similar to other researches. The benefits of integrated operation included convenience of data management, increase of emergency response, decrease of complains with sewage which was not reflected numerically, so the benefits of integrated operation were expected much greater than this result

Serial Use of Hydrodynamic and Water Quality Model of the Geum River using EFDC-Hydro and WASP7.2 (EFDC-Hydro와 WASP7.2 를 이용한 금강하류의 수리-수질 연계 모델링)

  • Seo, Dongil;Seo, MiJin;Koo, Myungseo;Woo, Jaekyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.15-22
    • /
    • 2009
  • This study reports the serial use of a 3-D hydrodynamic model, EFDC-Hydro and a dynamic water quality model WASP7.2 that are maintained by USEPA. The 48 km section of the Geum River downstream between Daechung Dam and Gongju was selected as a sample study site. Topographical information was used to accurately represent morphology of the study site and boundary conditions were derived from governmental databases including WAMIS by Ministry of Land and Ocean and WEIS by Ministry of Environment. EFDC-Hydro was successfully calibrated for observed water level and WASP was calibrated using monthly observed water quality data obtained from the above sources. It was found that the current water quality target of BOD for the Geum River-H point could not be met on monthly basis though every other tributary of the area would meet its own water quality target as assigned in Korean TMDL. This study proposed the new target BOD water quality for the Gabcheon and Mihocheon as 4.3 and 3.6 mg/l, respectively so that the Geum River-H point can meet the target. When Sejong City is constructed, it is estimated that effluent discharge limit of BOD must be less than 4.5 mg/l to meet water quality of the point. This study shows that it is possible to carry out more precise modeling considering both water movement and water kinetics by using EFDC and WASP simultaneously.

Effects of operating parameters on the performance of continuous flow microbial fuel cell (연속식 미생물연료전지 성능에 미치는 운전변수의 영향)

  • Chung, Jae-Woo;Choi, Young-Dae;Lee, Myoung-Eun;Song, Young-Chae;Woo, Jung-Hui;Yoo, Kyu-Seon;Lee, Chae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.4
    • /
    • pp.489-494
    • /
    • 2013
  • Effects of operating parameters such as hydraulic retention time(HRT), recycle ratio and influent COD concentration on the performance of a continuous flow microbial fuel cell(MFC) were investigated. Decrease of HRT improved mass transfer of substrate to electrogenic microorganisms, therefore resulting in increased electrode voltage and power generation of MFC. Increase of HRT promoted COD removal by elongating retention time for COD removal in MFC. Recycling of effluent increased the COD removal and coulombic efficiencies by returning suspended microorganisms into MFC. Increase of influent COD enhanced COD removal due to the improved mass transfer of substrate. Decrease of coulombic efficiency by the increase of the HRT and influent COD concentration indicated that they enhanced the activities of fermentative bacteria.