• Title/Summary/Keyword: Wastewater effluent

Search Result 880, Processing Time 0.024 seconds

Explanation of Foaming Mechanism and Experimental Application of Foam Reduction Techniques in the Treated Wastewater Outlet of Wastewater Treatment Plant Connected to a Tidal River, Korea (감조하천에 연결된 하수처리장 방류구의 거품 형성기작 해석 및 거품발생 저감기술의 실험적 현장적용)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.187-196
    • /
    • 2016
  • This study was performed to improve the foaming generated in the effluent of wastewater treatment plant from March 2015 to July 2016. The main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. Particularly, the foam growth was most active when there is low tide and larger discharge. To solve this problem, we experimented after installing fine mesh screen and the artificial channel device with underwater discharging outlet in the treated wastewater discharge channel and the outlet, respectively. As a result, the effects of foam reduction by devices ranged 85.0~92.0% and 70.7~85.6%, respectively. In addition, the foam and the noise were easily solved, first of all look to contribute to the prevention of complaints. Our device studies were applied to a single wastewater treatment plant. However, it is considered to be able to apply in other similar cases of domestic sewage treatment plants.

Application in Membrane Hybrid System with Acrylic Wastewater Pretreated by $TiO_2$ ($TiO_2$로 전처리한 아크릴 폐수의 Membrane Hybrid System에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek;Lee, Gang-Choon
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.183-188
    • /
    • 2009
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with $TiO_2$, it was utilized in MF/UF/RO process. After composing of ultrafiltration/reverse osmosis or microfiltration/reverseosmosiss module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. The permeate of ultrafiltration or microfiltration module was sent to reverse osmosis module. It was found that final permeate flux of reverse osmosis module in module set 2 (MWCO 200,000 UF+RO) was excellent. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in UF and MF modules. From the above result, the removal efficiency of TDS, T-N and COD was very excellent in RO module. The removal efficiency of turbidity in UF and MF module was very high (> 99% removal efficiency). Final water quality of acrylic wastewater treated by the membrane module set was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

Chronic Toxicities of Effluents from Dye Industry using Daphnia magna (물벼룩을 이용한 일부 염색폐수의 만성 수질독성 특성 연구)

  • Kim Younghee;Lee Minjung;Eo Soomi;Yoo Namjong;Lee Hongkeun;Choi Kyungho
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.2 s.58
    • /
    • pp.146-151
    • /
    • 2005
  • Recent studies indicated the utility of whole effluent assessment as a measure to control discharge of toxic effluents to receiving water in Korea. However, most studies have been focussed on acute lethal effects of toxic wastewater with little consideration of chronic sublethal impacts which are of growing concern in protecting aquatic ecosystem. We conducted acute and chronic toxicity tests with effluents discharged from five different dyeing plants in Gyeong-gi province using a marine bacterium Vibrio fischeri and a freshwater macroinvertebrate Daphnia magna to demonstrate the importance of assessing chronic sublethal effects. Various levels of acute and chronic toxicities were observed in many samples tested in this study. In 21-d chronic toxicity tests using D. magna all samples showed effects on reproduction and growth. Notable mortalities were also noted in three out of five effluents. The result of the Microtox assay indicated that acute microbial toxicity existed in effluents from two out of five plants and acute daphnid toxicity was observed in only one effluent. The result of this study clearly suggests chronic toxicity tests are more suitable to assess biological effects of effluents because it was shown from this study that even an effluent with no acute toxicity could cause chronically lethal and/or sublethal adverse effects on aquatic biota which may affect the population dynamics in aquatic ecosystem.

Mixing Zone Analysis on Outfall Plume considering Influence of Temperature Variation (수온 변화의 영향을 고려한 방류관 플룸의 혼합역 분석)

  • Kim Ji-Yeon;Lee Joong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.947-953
    • /
    • 2004
  • As a large scale port development in coastal waters proceeds step by step and populations in the vicinity of port are getting increased, the issue on 'how to dispose the treated municipal water and wastewater in harbor' brings peoples' concern. The submarine outfall system discharges the primary or secondary treated effluent at the coastline or in deep water, or between these two. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding sea water and becomes very dilute. We intended in this paper to investigate the impact on dilution of effluent and the behavior of flume under the conditions of the seasonal and spatial temperature variations, which have not been noticeable in designing effective marine outfall system. To predict and analyze the behaviour and dilution characteristics of plume not just with the effluent temperature, but also with the seasonal variation of temperature of surround water, CORMIX( Cornell Mixing Zone Expert System)-GI have been applied. The results should be used with caution in evaluation the mixing zone characteristics of discharged water. We hope to help for the effective operation of outfall system, probable outfall design, protection of water quality, and warm water discharges from a power plant, etc.

A Study on the Characteristics of the Treatment with Bed Expansion and the Biomass Attachment in the Start-up of the AFBR (혐기성 유동층 반응기에서 층팽창에 따른 처리특성 및 미생물 부착특성)

  • 안재동;정종식;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.20-26
    • /
    • 1995
  • The objective of this study is to estimate the effect of the bed expansion and the characteristics of attached biomass in the start-up in the anaerobic fluidized bed reactor(AFBR). The fluidized bed reactor was operated with bacteria supported on the bed of granular activated carbon(GAC). The reactor was operated at 35$\circ$C, 5 kg $COD/m^3\cdot day$ at bed expansion varying from 0 to 100% with soluble glucose wastewater(5,000 mg/l). When the effluent reached a steady state at 100% of bed expansion, maximum COD removal efficiency of 87.3% and 0.031 $m^3CH_4/kg COD_{removed}$ were obtained. At higher bed expansion, COD removal efficiency, methane production rate and biogas production rate increased. Especially, at 50% of bed expansion, the efficiency of the treatment increasedg rapidly in the AFBR. The biomass colonized in the pits and crevices of the GAC particle and no complete biofilm was established in the bioreactor during the experiment.

  • PDF

ENVIRONMENTAL RISK ASSESSMENT OF CHEMICALS - INDUSTRY APPROACH

  • Jung, Keumhee
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2001.05a
    • /
    • pp.107-113
    • /
    • 2001
  • Consumer Product compounds are used in homes and disposed in wastewater where they typically receive waste treatment. After treatment, sludge and effluent are released to the environment resulting in the potential exposure of terrestrial and aquatic organisms to these compounds. To ensure the environmental safety of these compounds, the environmental risk posed by chemicals released into the environment must be assessed. A reasonable, consistent and cost-effective method to conduct environmental risk assessments and to prioritize testing of these chemicals is needed which addresses risk to organisms residing in the terrestrial and aquatic compartments of the environment. This paper provides a fundamental understanding of the technical basis of environmental risk assessment using the major surfactant(i.e., LAS) used in the laundry detergent industry worldwide as a case study.

  • PDF

Effect of Hydraulic Retention Time on Biological Nitrogen Removal in Land-based Fish Farm Wastewater (육상양식장 배출수내 생물학적 질소처리시 수리학적 체류시간의 영향)

  • Park, Noh-Back
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.250-256
    • /
    • 2017
  • This study investigated the removal efficiency of organic matter and nitrogen from fish farm effluent by hydraulic retention time (HRT) using an upflow biological filter (ANR system) reactor. The recycling time and influent flow in the reactor were controlled to 14.8, 7.4, 5.5 and 3.2 h to evaluate HRT. In addition, each reactor was coupled to a fixed bed upflow filter charged with media. The results showed that removal efficiency was ${\geq}95%%$ with an HRT of 5.5 h, and nitrification efficiency was reduced to 81% with an HRT of 3.2 h, although nitrification efficiency temporarily decreased due to the shock load as HRT decreased. Total nitrogen removal rate was also reduced to about 65% with an HRT of 3.2 h, which was considered a washout effect of nitrifying and denitrifying microorganisms by increasing the shearing force to the filter media, which decreased organic matter and nitrogen removal efficiency.

Mortality Rates of Pathogen Indicator Microorganisms Discharged from Point and Non-point Sources in Urban Area (도시지역 점원, 비점원에서 유출되는 병원균 지표미생물의 사멸률)

  • Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1075-1081
    • /
    • 2006
  • In this research, mortality rates of pathogen indicator microorganisms discharged from various point sources and diffuse sources in urban area were measured. Water samples were taken at domestic sewer, combined sewer overflow, effluent from a wastewater treatment plant, urban river, and sediment of an urban river. Mortality rates of indicator microorganisms in domestic sewer estimated by assuming the first order kinetics at $20^{\circ}C$ were as follows: total coliform = 0.092/day, fecal coliform = 0.185/day, E. coli = 0.252/day, and fecal streptococci = 0.281/day. Sensitivity of mortality rates of total coliform on temperature was estimated as $K_{temp}=K_{20}{\times}1.162^{(temp-20)}$ for the range of $10-20^{\circ}C$. Mortality rates due to sunlight were measured as 1.22-1.59/day while mortality rate due to settling for 40 min were estimated as $9.21{\times}10^3-20.0{\times}10^3/day$.

Tertiary Treatment of Municipal Wastewater and Bypassed Rainfall Treatment using by BAF (BAF를 이용한 하수의 3차 처리 및 by-pass된 우수의 처리)

  • Lee, Kwang Je;Park, Jae-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.327-331
    • /
    • 2005
  • The study was conducted with two laboratory biological aerated filter (BAF) reactors: denitrification filter (DF) and nitrification BAF. The influent flow (Q) was fixed to 48 L/d and total empty bed contact time (EBCT) was 1 hr. The flow direction was upflow with NRCY of 1 to 2Q. The secondary effluent was fed to the reactors and the influent concentrations were adjusted with some stock solutions to simulate by-pass concentration during rainfall. The study results indicate that COD and SS removal efficiencies were excellent and not influenced by temperature. Nitrification efficiency was over 90% at the influent loading less than $1.12kg/media\;m^3/d$, but the efficiencies were decreased in low temperature. TN removal efficiencies were 10% to 60%.

A Study on the Recovery of Carbon Energy by Thermophilic Aerobic Digestion (고온호기성 소화공정을 이용한 탄소원 회수에 관한 연구)

  • Yi, Yunseok;Kim, Ryunho;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.906-912
    • /
    • 2007
  • A lab-scale thermophilic aerobic digestion (TAD) system was operated at $64^{\circ}C$ with mixed primary and secondary sludges taken from a large wastewater treatment plant. The semi-continuously operated reactor at HRTs of 1, 3 and 6 days indicated that longer HRT could stabilize sludge organics and solids comparable to anaerobic digestion. It has been found that reduced HRT of 3 and 1 day produced the effluent with highly biodegradable soluble organics, indicating the possibility of energy recovery in TAD. No proof of biological nitrification was observed at thermophilic operating temperature of $64^{\circ}C$, while nitrogen removal seemed due to nitrogen exertion during the aerobic thermophilic cell synthesis as well as ammonia stripping.