• Title/Summary/Keyword: Waste gas treatment

Search Result 241, Processing Time 0.023 seconds

Estimation of Greenhouse Gas Reduction Potential by Treatment Methods of Excavated Wastes from a Closed Landfill Site (사용종료매립지(使用終了埋立地) 폐기물(廢棄物)의 처리방법별(處理方法別) 온실(溫室)가스 저감량(低減量) 평가(評價))

  • Lee, Byung-Sun;Han, Sang-Kuk;Kang, Jeong-Hee;Lee, Nam-Hoon
    • Resources Recycling
    • /
    • v.22 no.6
    • /
    • pp.3-11
    • /
    • 2013
  • This study was carried out to estimate greenhouse gas reduction potentials under treatment methods of combustible wastes excavated from closed landfill. The treatment methods of solid wastes were landfilling, incineration, and production of solid recovery fuel. The greenhouse gas reduction potentials were calculated using the default emission factor presented by IPCC G/L method of IPCC (Intergovernmental Panel on Climate Change). The composition of excavated waste represented that screened soil was the highest (65.96%), followed by vinyl/plastic (19.18%). This means its own component is similar to the other excavated waste from unsanitary landfill sites. Additionally, its bulk density was 0.74 $t/m^3$. In case of landfilling of excavated waste, greenhouse gas emission quantity was 60,542 $tCO_2$. In case of incineration of excavated waste, greenhouse gas emission quantity was 9,933 $tCO_2$. However, solid recovery fuel from excavated waste reduced 33,738 $tCO_2$ of the greenhouse gas emission quantity. Therefore, solid recovery fuel production is helpful to reduce of greenhouse gas emission.

Study on Pertinence for Environmental Energy Complex Town Construction (환경에너지 종합타운 조성 타당성에 관한 연구)

  • Kim, Young-Jun;Lee, Jong-Yeon;Kang, Yong-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.164-171
    • /
    • 2011
  • The objectives of this study are to propose a suitable treatment facility for waste energy recovery after analyzing the waste generation and disposal situation in Jejudo, to establish the plan to install the solar photovoltaics and wind power plant considering the site conditions and finally to establish the environmental energy town plan in conjunction with the existing facilities. The food waste biogas plant is selected as the treatment capacity of 200 ton/day. It is estimated that the biogas plant will produce the electricity of 7,594 MWh per year, which will reduce the greenhouse gas of 4,177 $tCO_2$ per year. The solar photovoltaics and wind power plant will produce the electricity of 13,410 MWh per year, which will reduce the greenhouse gas of 7,375 $tCO_2$ per year. Environmental energy town will give us the reduction of operating cost by centralized treatment of residues and byproducts, and by efficient utilization of produced energy.

A Study on the Treatment of Combustible Wastes and the Resource Recovery by Pyrolysis (熱分解에 의한 可燃性 廢棄物의 처리 및 資源回收에 관한 연구)

  • Kim, Sam-Cwan;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.1
    • /
    • pp.17-33
    • /
    • 1987
  • As a result of technical advances and industrialization, the characteristics of domestic and industrial wastes are becoming more complex. Accordingly, improved treatment and disposal systems are being continuously sought to take account of complex characteristics and to comply with economic restrictions. In this study, an application of pyrolysis to the treatment of industrial wastes, including waste scrap rubber, waste raw material used in making the slipper bottom and waste PVC pipe, and the effectiveness of pyrolysis in resource recovery from these wastes were investigated. Batches of wastes were pyrolysed by external heating to a temperature of 400-800$\circ$C in a 32 mm diameter x 0.9 m long silica tube to produce combustible gases, oils and chars. Before the start of pyrolysis runs, the entire system was purged with nitrogen gas to exclude the air. The temperature inside the retort was controlled by the thermocouple in the gas stream, and referred to as the pyrolysis temperature. Under these conditions three products were separately collected and further analyzed. The results were summarized as follows. 1. More gases and less chars were produced with higher pyrolyzing temperature and with higher rates of heating, but the yields of oils tended downwards at temperatures above 700$\circ$C. Accordingly, operating conditions of pyrolysis should be varied with desired material. 2. Calorific values and sulfur contents of produced oils were sufficient and suitable for fuel use. Chars from waste rubber had high heating values with low sulfur contents, but calorific values of chars from waste PVC and waste slipper were as low as 3, 065-4, 273 kcal/kg and 942-2, 545 kcal/kg, respectively. Therefore, char from these wastes are inappropriate for fuel. 3. Soluble contents of Pb, Cd, Cu and Zn in chars from waste rubber and waste slipper were below the Specific Hazardous Waste Treatment Standards. However soluble contents of Pb and Cd in chars from waste PVC were one or two times and five or seven times exceedingly the Specific Hazardous Waste Treatment Standards, respectively. 4. Post high heating is desirable for treatment method of waste PVC which generates toxic hydrogen chloride. 5. The proportions of hydrogen, methane and ethane in produced gases were in the range of 3.99-35.61% V/V, 18.22-32.50% V/V and 5.17-5.87% V/V, respectively. 6. Pyrolysis is a useful disposal method in case of waste slipper, which was hardly combustible, and thus investigations of this kind of materials are required for effective management of industrial waste. 7. Based upon the possible market development for products, overall pyroly economics to take account of treatment values of noncombustible or hazardous materials should be evaluated.

  • PDF

MEMBRANE PROCESSES IN ENVIRONMENTAL TECHNOLOGY

  • Blume, I.;Smolders, C.A.
    • Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.1-20
    • /
    • 1992
  • Classical membrane processes like microfiltration (MF), ultrafiltration (UF) and reverse osmosis (RO) are being applied in the last years more frequently in environmental and effluent process problems. Newer technologies and developments like pervaporation (PV) and gas sepaxation (GS) recently found commercial applications in the treatment of waste waters and gas streams. The incentive here is either the clean-up from organic components to comply with federal emission regulations or the recovery of the organics for economical reasons. Processes still in their development stage are combinations of chemical reactions with membrane processes to separate and treat $SO_x$ and $NO_x$ laden waste gas streams in the clean-up of stack-gases. In this paper we will first give a short overview of the more recent developments in MF, UF and RO. This is followed by a closer look on newer technologies applied in environmental problems. The applications looked at are the recovery of organic components from solvent laden gas streams and the separation of organic volatiles from aqueous waste waters via pervaporation. Technical solutions, the advantages and disadvantages of the processes and. where possible, cost estimations will be presented.

  • PDF

Pilot scale biofilter를 이용한 축산폐수의 악취제거

  • Park, Jeong-Yeop;Mun, Cheol-Hyeon;Jang, Seok-Jin;Hwang, Jae-Ung;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.415-418
    • /
    • 2002
  • A performance of pilot scale biofilter was investigated for the treatment of odorous waste gas. The system treated 508.7 $m^3h^{-1}$ of waste air with amine and ammonia concentrations ranging up to 0.06 $N-gm^{-3}$ Over the four month study, its elimination capacity was demonstrated up to 6.37 $N-gm^{-3}h^{-1}$ and its removal efficiency was 100%. Differ to lab scale biofilter, It is difficult to maintain the proper temperature of reactor because of low external temperature. Experiments were performed indicating various problem such as sudden system shut down, unstable pump, water addition malfunction and corrosion of reactor. However, pilot scale biofilter was stable when treatment of odorous waste gas.

  • PDF

Study on the Heat Recovery Design Methods for the Flue Gas from Combustion and Incineration Processes (연소 또는 소각 과정에서 발생하는 배기가스의 폐열 회수 설계 방법에 관한 연구)

  • Lee, Chan;Jung, Bong-Jin
    • Clean Technology
    • /
    • v.5 no.2
    • /
    • pp.53-61
    • /
    • 1999
  • Presented is the design method of the waste heat recovery facility for the flue gas produced from combustion and incineration processes of large industrial environmental waste treatment and cogeneration plants. The present study assumes the basic design concept of wast heat recovery facility as the combination of waste heat recovery boiler and steam power cycle, and then describes the modeling technique, the design concept and criteria of each component of waste heat recovery facility. In addition, the present study investigates how the thermal performance of waste heat recovery facility varies with boiler operating pressure and waste heat recovery heat exchanger design at the same flue gas condition.

  • PDF

Uncontrolled Landfill Maintenance Plans through the Environmental Evaluation (환경성평가를 통한 비위생 매립지 정비방안)

  • Lee, Hae-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.59-71
    • /
    • 2008
  • In this study, we intend to present the uncontrolled landfill maintenance plans by diversely reviewing the operating conditions of landfill and environmental effects and economical issues resulted from the operation of landfill for the purpose of suggesting the optimal maintenance plans applicable to the uncontrolled landfill and unused landfill located in Korea. We perform the basic and precise surveys against three landfill sites showing the biggest problem out of 8 unsanitary landfills sites located in Y County. We compare and review the treatment plans prepared and operated by the N Landfill. The compared and reviewed results show that the local stabilization plan is more effective than the excavation and transfer treatment plan when considering the economic efficiency only. However, the excavation and transfer treatment plan is valid when considering the diverse elements. The G Landfill is operated with separated into living waste landfill section and construction waste landfill section. However, some landfill gas collection bores or holes are installed in its living waste landfill section, which has not been used for about 20 years, as a part of follow-up control. The element causing the environmental damage is considerably reduced in its living waste landfill section. However, the effort to keep the follow-up control through the local stabilization work is required. The landfill is under processing in the construction waste landfill section. However, most of buried wastes are the inorganic wastes such as waste materials and concrete, so the maintenance plan focused on the use of top land by installing the local stabilization facilities is considered as an effective plan. The landfill is under processing in the K Landfill. It seems to be difficult to maintain this landfill through the local stabilization. The excavation and transfer treatment plan to completely remove the potential environmental pollution source is considered as the valid plan.

Stabilization of Plasma in a Three-Phase AC Plasma Generator (삼상 교류 플라즈마 발생의 안정화)

  • Lee, K.H.;Kim, K.S.;Lee, H.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.209-211
    • /
    • 2002
  • A simple-structured thermal plasma generator for waste gas treatment has been studied. The thermal plasma technology applied to waste treatment has undoubtedly gained high importance owing to its outstanding properties such as flexibility, compact reactor, and clean treatment. Moreover, the thermal plasma generated by ac power has some additional advantages such as simple electrode system and easy maintenance. A prototype 200kW class plasma generator with specifications of 10-30m/sec gas velocity and 3000-5000K temperature on the center just outside of the nozzle has been designed and tested. Case studies on heat transfer, heat flow, velocity distribution, and temperature distribution using a commercial simulation package show lots of flexibility in design. The experimental results from theprototype generator show that the ac thermal plasma is easily controlled by working gas flow once it is ignited. A stabilization condition is discussed with the data from monitoring arc voltage drops with respect to gas flow rate during the test.

  • PDF

Determination of Residual Pesticides in Recycle Product of Waste Plastic Pyrolysis (폐비닐 열분해 재활용품 중의 잔류농약 분석)

  • Shin Hea Soon;Shim Sung Hoon
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.3
    • /
    • pp.315-320
    • /
    • 2004
  • Environmental waste treatment technology is transforming from incineration system to pyrolysis gasification system. And there it is necessary for our country to adapt gasification system urgently to prevent the land pollution and lack of landfill area. The objective of this study was to determine the pesticides residues of derived product of pyrolysis gasification system for recycling of waste plastic by gas chromatograph-mass selective detector and nitrogen phosphorus detector. The residual pesticides were not detected in derived product of waste recyling. But some pesticide was detected on raw level (0.02 ~ 0.05 ppm) in waste plastic sample.