• 제목/요약/키워드: Waste Removal

검색결과 1,010건 처리시간 0.031초

ALC(Autoclaved Light-weight Concrete)를 이용한 생물학적 반응벽체에 관한 연구

  • 박근민;이재영;오병택;최상일
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.402-406
    • /
    • 2006
  • The physical and chemical characteristics of ALC were analyzed and showed 2.2 of specific gravity and 9.05 of pH. The results of leaching tests with standard method for soil and waste indicated heavy metals(Cu, Cd, Pb, $Cr^{6+}$) were under maximum concentration level. The anaerobic digestion sludge was attached in the surface of ALC within 90 hours. As the results of batch test, pH of the ALC and Bio-ALC were decreased from initial pH of ALC to 8.7 and 7.8 respectively Also, the concentration of heavy metals was rapidly eliminated in the solution with the batch test. The result of column experiment indicates that the removal efficiency of ALC was showed 66% of T-P, 60% of T-N, and 67% of CODcr. Also, removal efficiency of Bio-ALC was slightly higher than that of ALC in T-N (64%) and CODcr (74%).

  • PDF

칼슘과 마그네슘염을 이용한 축산폐수의 응집처리 (Treatment of stock wastewater by flocculation with Calsium and Magnesium salts)

  • 김재용
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.10-18
    • /
    • 2002
  • The changes of conventional clarification processe and an increase in treatment cost are required to meet increasingly stringent regulations related to the treated water quality. Although many enhanced coagulations have introduced to improve organic matter removal, the results to remove color, nitrogen and phosphorus as well as organic material have not been very efficient yet. In this context as new flocculation using calcium hydroxide and magnesum sulfate was carried out. The removal of waste matters such as SS, organic matter, COD, nitrogen and phosphorus contained in stock wastewater was carried out by using the combination of calcium hydroxide and magnesium sulfate. The flocculation was investigated as a function of coagulant dose, pH, mixing time, settling time and coagulant addition modes such as the sequential addition of the two coagulants and the simultaneous addition of them. The flocculation by the combination of calcium hydroxide and magnesium sulfate was compared with that by aluminum sulfate. The mechanism of flocculation was investigated as well. About 60% of COD in stock watewater was removed by flocculation with combination of calcium hydroxide and magnesium sulfate.

Adsorption of Specific Organics in Water on GAC and Regeneration of GAC by Countercurrent Oxidative Reaction

  • Ryoo, Keon-Sang;Kim, Tae-Dong;Kim, Yoo-Hang
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권6호
    • /
    • pp.817-824
    • /
    • 2002
  • Granular activated carbon(GAC) is highly effective in removing organic compounds which are resistant to biological disintegration in wastewater treatment. However, GAC has reached its full adsorptive capacity, GAC needs to be regenerated before it can be used for a further adsorption cycle. Countercurrent oxidative reaction (COR) technique has been developed and evaluated for the regeneration of spent GAC. Various parameters such as flame temperature, the loss of carbon, destruction and removal efficiency (DRE) of organic compounds, surface area, surface structure, adsorptive capacity, etc. were examined to determine the performance of COR. The results of these tests showed that adosorptive capacity of regenerated GAC was completely recovered, the loss of carbon was controllable, flame temperature was high enough to insure complete destruction and removal $(\geq99.9999%)$ of specific organics of interest, polychlorinated biphenyls (PCBs), that are thermally stable, and on formation of toxic byproducts such as polychlorinated dibenzo-p-dioxins (PCDDs) or polychlorinated dibenzofurans (PCDFs) were detected during the regeneration process. The COR technique is environmentally benign, easy to use and less copital intensive than other available regeneration technologies.

매립지 침출수가 도시하수처리에 미치는 영향 (Effects of Landfill Leachate on the Treatment of Municipal Wastewater)

  • 장지희;김영관
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.117-123
    • /
    • 1996
  • A bench-scale continuous activated sludge system was operated in order to study the effects of solid waste landfill leachate on municipal wastewater treatment. The leachate sample was collected from Nanjido landfill. During the 7 weeks of operational period, the leachate content in the influent fed to the system was increased stepwise from 3% to 5% and 7%. The solids retention time was the major process control parameter, and it was 10 days. With the municipal wastewater alone, COD removal was 75%. The removal percents, however, decreased to 60% and 45% when the leachate content was 3% and 7%, respectively. For the wastewater spiked with the leachate, the sludge production was higher than for the municipal wastewater alone. Sludge settleability determined by SVI deteriorated with the increase of leachate content. The specific oxygen uptake rate, however, was measured higher as leachate content increased.

  • PDF

숯 제조공정에서 발생하는 대기오염물질의 제거기술 (Removal of Air Pollutants from Charcoal Production Process Exhaust)

  • 박성규;최상진;김대근;황의현
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.350-361
    • /
    • 2014
  • Exhaust gas containing wood tar of high concentration is discharged from charcoal production kilns. The large amount of emissions are often found by operational failure. The purpose of this study is to investigate the performance of an integrated treatment system in treating charcoal production exhaust. The system, which combined a tar collection device and a post-combustion unit, was proposed to remove moisture, wood tar, particulate matter, and other gas-phase pollutants (CO, $CH_4$, total hydrogen carbons) from exhaust gases. Heat recovery units were also applied in the system to utilize waste heat.

Removal Characteristics of Heavy Metal by Na-P1 Zeolite Synthesized from Coal Fly Ash

  • Mingyu Lee;Don
    • 한국환경과학회지
    • /
    • 제1권2호
    • /
    • pp.167-175
    • /
    • 1992
  • This study was conducted for an efficient utilization of waste fly ash obtained from the power plant. Fly ash was used for synthesizing zeolite. Na-Pl zeolite could be easily synthesized from waste fly ash and showed the potential to remove heavy metal ions. The synthetic zeolite showed good adsorption property for heavy metal much better than raw fly ash and natural zeolites. Na-Pl exhibited the high adsorption efficiency with a maximum value of 260 Pb mg/g and strong affinity for Pb2+ ion. The metal ion selectivity of Na-Pl was determined in a decreasing order : $Pb^{2+}$>$Cd^{2+}$>$Cu^{2+}$+>$Zn^{2+}$>$Fe^{3+}$

  • PDF

인공습지와 연못시스템을 이용한 오수처리 (Waste Water Treatment Using Constructed Wetland and Pond System)

  • 김민희;윤춘경;함종화
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.470-474
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the waste water treatment using constructed wetland and pond system. The effluent of the wetland system in winter often exceeded effluent water quality standards for sewage treatment plant, therefore, pond system could be applied to additional system. As a result, removal rate of $BOD_{5}$, SS was 84.4%, 81.5% and effluent concentration was 4.6mg/L and 5.0mg/L respectively, when surface water of pond system was discharged in March. So we concluded that pond system stored wetland effluent in winter and discharged surface water of pond system in March, so met water quality standard.

  • PDF

산화철계 형석대체제의 전로 정련특성 (BOF Refining of Fluorspar Substitute Using Iron Oxide Based By-product)

  • 금창훈;허보영
    • 한국재료학회지
    • /
    • 제16권5호
    • /
    • pp.336-340
    • /
    • 2006
  • Fluorspar has been essential flux in steelmaking process. The main effects of fluorspar addition are lowering of the viscosity and melting temperature of slag. In recent years, due to the increasing price and environmental problem of fluorspar, various types of fluorspar substitute have been investigated. In this study, iron oxide by-products such as sinter dust, basic oxygen furnace (BOF) sludge and mill scale were developed as a substitute in terms of waste recycling. Several plant trials were carried out by addition of briquetted substitutes of $4{\sim}6$ kg/ton to compare with the fluorspar of $0.7{\sim}1$ kg/ton. The substitutes showed a similar behavior of slag formation, phosphorus removal and MgO saturation content.

은의 전해채취 및 전해정련을 통한 사진폐액의 처리에 관한 연구 (Studies on the Treatment of Photographic Wastewater by Electrowinning and Electrorefining of Silver)

  • 정원주;김동수;이화영
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.658-665
    • /
    • 2006
  • The removal characteristics of silver ion from waste photographic solution have been investigated by recovering silver electrochemically. Cyclic voltammetry for synthetic and actual wastewater which containing silver ion was investigated to understand its electrochemical behavior. For both synthetic and actual wastewater, the recovery of silver according to the electrowinning time was observed to be increased as the applied potential was raised. In addition, the applicable potential for the electrowinning of silver was found to be lower for synthetic wastewater compared with actual wastewater. As the temperature was increased, more silver was recovered for both wastewater, which indicated the electrowinning reaction was endothermic. The electrowinned silver was refined electrochemically to increase its purity and the variation of the purity of silver was examined according to the electrorefining potential.

Red Mud를 이용한 토양 및 슬러지내 중금속 제거 특성

  • 김이태;배우근;김우정;정원식
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.73-77
    • /
    • 2003
  • Red mud is a waste material formed during the production of alumina when the bauxite ore is subjected to caustic leaching. It is a brick-red colored highly alkaline (pH 10-12) sludge containing mostly oxides of iron, aluminum, titanium, and silica. Red mud, due to its high aluminum, iron, and calcium contents, has been suggested as a cheap adsorbent for removal of toxic metals (e.g., As, Cr, Pb, Cd) as well as for water or wastewater treatment. The basic advantage of red mud is its versatility in application. This study was conducted to evaluate the effect of red mud on stabilization and fixation of heavy metals (such as Pb, Cu, C $r^{6+}$, Cd, Zn) contained in the Al-coating sludge and soil. The results showed that the concentration of heavy metals leached from the treated sludge and soil was low, meeting the regulatory permit level.

  • PDF