• Title/Summary/Keyword: Waste Removal

검색결과 1,010건 처리시간 0.025초

산용해 및 초음파를 이용한 하수 슬러지의 산발효 특성 (Acid Fermentation Characteristics of Waste Activated Sludge using Acids and Ultrasonication)

  • 손춘호;홍승모;이병헌
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.781-788
    • /
    • 2007
  • The Carbon source to enhance the denitrification is essential matter in the advanced sewage treatment. For the high level of nutrient removal, external carbons such as ethanol, methanol, volatile fatty acids and so on should be needed. In this study, the methods to increase the sludge solubilization and acidification rate were compared with waste activated sludges and food waste leachate. Ultrasonication and acids were used for the pretreatment of organic particles in sludges. As a results, the optimal temperature and HRT were $60^{\circ}C$ and 5 days, respectively. HAc, HPr, HBr, and other VFAs for acid fermentations reduced up to 22, 16, 14, and 48% with HRT reduction. For the increase of solubilization, 28% of solids destruction rate was shown at 0.3 watts/mL.

E.V.A., 고무폐기물 소각에 따른 폐가스 처리의 연구 (Combustion Characteristics of E.V.A., Rubber Waste Treatment by Fixed-Bed Incinerator.)

  • 배병훈;장성호;임경택
    • 한국환경과학회지
    • /
    • 제5권2호
    • /
    • pp.221-227
    • /
    • 1996
  • The objectives of this study are to examine combustion characteristics of E.V.A. and rubber wastes by fixed-bed incinerator, The results are as follows. Combustion temperature with time rises rapidly, and mass of E.V.A. reduces at short time in E.V.A. combustion. In variation of air-fuel ratio (m), ice ideal values of m of E.V.A. and rubber are 2.5, 1.5 respectively. Mixed-waste combustion is more economic than single E.V.A. combustion, because we can get high combustion efficiency (94.0~99.0%) at 2.0 air-fuel ratio of mixed-waste combustion. Removal efficiencies of SO2 at cooling tower are about 20%. The combustion efficiencies of rubber are over 98.0% according to the experimental conditions.

  • PDF

A Study on Characteristics of Water Quality in Wastewater according to the Washing of Municipal Solid Waste Incinerator (MSWI) Ash

  • Byun, Mi-Young;Kim, Hyung-Seok;Ahn, Ji-Whan;Kim, Hwan
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.296-300
    • /
    • 2001
  • In order to recycle the incineration ash (bottom ash and fly ash) generated from the incineration of municipal waste for a cement material, salts as well as heavy metal should be removed by the stabilization treatment. Most of these heavy metal and over 80% of salts are removed by a washing as a pre-treatment. However, wastewater which is another pollutant is generated by a washing, then proper treatment should be developed. First the characteristics of incineration ashes collected from two domestic full-sized incinerators were investigated and removal rate of salts and heavy metals from them also studied. The wastewater quality was compared to the criteria of the regulation by analyzing the characteristics of generated wastewater during the washing of incineration ash as a condition of liquid/solid ratio. Also, we tried to used this experimental results for the basic data to develop proper processing technique of municipal waste.

  • PDF

No-binding Molding Technology Development for Waste Rubber Recycling

  • Zhang, Xiao Jie;Hong, Sung Woo;Kim, Jin Kuk
    • Elastomers and Composites
    • /
    • 제53권1호
    • /
    • pp.19-25
    • /
    • 2018
  • In this study, a new process was developed to develop the waste rubber material recycling system. Firstly, the blending of the reclaimed rubber/virgin rubber as a compounding technology was investigated in this study. Secondly, the removal of odor by using zeolite. Thirdly, the continuous crosslinking process technology was studied the technology can solve the environmentally harmful substances and economic problems. Based on this technology, we have started to develop application technologies such as floor mats and rubber sheets for forklifts, and will further study the environmentally conscious products in various ways. Our research will contribute to the recycling industry.

Pilot scale biofilter를 이용한 축산폐수의 악취제거

  • 박정엽;문철현;장석진;황재웅;박성훈
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.415-418
    • /
    • 2002
  • A performance of pilot scale biofilter was investigated for the treatment of odorous waste gas. The system treated 508.7 $m^3h^{-1}$ of waste air with amine and ammonia concentrations ranging up to 0.06 $N-gm^{-3}$ Over the four month study, its elimination capacity was demonstrated up to 6.37 $N-gm^{-3}h^{-1}$ and its removal efficiency was 100%. Differ to lab scale biofilter, It is difficult to maintain the proper temperature of reactor because of low external temperature. Experiments were performed indicating various problem such as sudden system shut down, unstable pump, water addition malfunction and corrosion of reactor. However, pilot scale biofilter was stable when treatment of odorous waste gas.

  • PDF

Optimal conditions for biological hydrogen production from food waste

  • Wongthanate, Jaruwan;Chinnacotpong, Kittibodee
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.121-125
    • /
    • 2015
  • Biohydrogen production from food waste via dark fermentation was conducted by using mixed culture under various environmental conditions (initial pH, initial F/M ratio, initial ferrous iron ($Fe^{2+}$), and temperature condition) in batch reactor. The results revealed that the maximum hydrogen yield of $46.19mL\;H_2/g\;COD_{add}$ was achieved at the optimal conditions (initial pH 8.0, initial F/M ratio 4.0, initial iron concentration 100 mg $FeSO_4/L$ and thermophilic condition ($55{\pm}1^{\circ}C$)). Furthermore, major volatile fatty acid (VFA) productions of butyrate (765.66 mg/L) and acetate (324.69 mg/L) were detected and COD removal efficiency was detected at 66.00%. Therefore, these optimal conditions could be recommended to operate a system.

진동막 분리장치를 이용한 제지폐수의 재이용에 관한 연구 (A study on the pulp and paper mills waste water Recycling by VSEP membrane system)

  • 지은상;김재우;신대윤
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.40-46
    • /
    • 2001
  • Conventional membrane systems was difficult to treatment for pulp and paper mills waste warter. Technological advances in membrane filtration systems have created opportunity for pulp and paper mills to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes if possible to filter effluent streams without the fouling problems exhibited by conventional membrane systems. Various kinds of waste water occurred to and paper mills experiment with "VSEP" set up conventional membrane. The results were as followes : Excepting ultra filter($0.1{\mu}\textrm{m}$ Teflon, C-100, G-50), Nano filter(NTR-7450, DS-5, PVD-1) and reverse osmosis(ACM-4) was treated with very excellent weight of treatment, electric conductivity, removal COD, TDS, turbidity.

  • PDF

왕겨의 재활용 및 하수처리 활용기술 개발 (Reuse of Rice-Hull and Application Technology Development in Waste Water Treatment)

  • 신호상;안혜실;정동균
    • 한국자원리싸이클링학회:학술대회논문집
    • /
    • 한국자원리싸이클링학회 2003년도 추계정기총회 및 국제심포지엄
    • /
    • pp.170-173
    • /
    • 2003
  • Activated Rice-Hull carbon was developed to remove ammonia compounds in water matrix. Isotherm adsorption tests of ammonia were conducted using a bottle-point technique and column test. Residual ammonia after Jar-Test or passing through the column was determined by Indophenol method, and assessed the removal efficiency for ammonia of the adsorbent. As a result, the adsorption capacity for ammonia of activated racehull carbon was very larger than that of coconut shell carbon, because the rice hull carbon had the higher BET surface area of silicate. The activated racehull carbon is under the development as adsorbent to remove ammonia in drinking water and waste water.

  • PDF

Separation and purification of elements from alkaline and carbonate nuclear waste solutions

  • Alexander V. Boyarintsev ;Sergei I. Stepanov ;Galina V. Kostikova ;Valeriy I. Zhilov;Alfiya M. Safiulina ;Aslan Yu Tsivadze
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.391-407
    • /
    • 2023
  • This article provides a survey of wet (aqueous) methods for recovery, separation, and purification of uranium from fission products in carbonate solutions during the reprocessing of spent nuclear fuel and methods for removal of radionuclides from alkaline radioactive waste. The main methods such as selective direct precipitation, ion exchange, and solvent extraction are considered. These methods were compared and evaluated for reprocessing of spent nuclear fuel in carbonate media according to novel alternative non-acidic methods and for treatment processes of alkaline radioactive waste.

AgX (Ag-함침 X 제올라이트)에 의한 고방사성해수폐액으로부터 요오드(I)의 흡착 제거 (Removal of I by Adsorption with AgX (Ag-impregnated X Zeolite) from High-Radioactive Seawater Waste)

  • 이일희;이근영;김광욱;김형주;김익수;정동용;문제권;최종원
    • 방사성폐기물학회지
    • /
    • 제14권3호
    • /
    • pp.223-234
    • /
    • 2016
  • 본 연구는 AgX (Ag-함침 X zeolite)에 의해 고방사성해수폐액 (HSW)의 발생초기에 함유되어 있는 고방사성 요오드($^{131}I$)의 흡착, 제거를 목표로 수행하였다. AgX에 의한 I의 흡착 (AgX-I 흡착)은 AgX 내 Ag-함침농도가 증가할수록 증가하며, 함침농도 30wt% 정도가 적당하였다. AgX (Ag-함침 약 30~35wt%)로부터 Ag의 침출농도는 해수폐액에 함유되어 있는 chloride 이온에 의한 AgCl 침전 등으로 증류수보다 덜 침출 (<1 mg/L) 되었다. AgX-I 흡착은 초기 I 농도 0.01~10 mg/L의 경우 m/V(흡착제량/용액부피의 비)=2.5 g/L에서 99% 이상 흡착제거 되어 I의 효율적 제거가 가능함을 알 수 있다. AgX-I 흡착제거는 해수폐액 보다는 증류수에서 수행하는 것이 효과적이고, 온도의 영향은 미미한 것 같으며, 흡착평형등온선은 Languir 보다는 Freundlich 등온선으로 표현하는 것이 양호하였다. 한편 AgX-I 흡착속도는 유사 2차 속도식을 만족하고 있으며, 속도상수 ($k_2$)는 $C_i$ 증가에 따라 감소하고 있지만, m/V 비 및 온도 증가에 따라서는 증가하고 있다. 이때 흡착 활성화에너지는 약 6.3 kJ/mol 로 AgX-I 흡착은 약한 결합형태의 물리적흡착이 지배적일 것으로 보인다. 그리고 열역학적 매개변수를 평가(음수 값의 Gibbs 자유에너지 및 양수 값의 엔탈피)에 의해 AgX-I 흡착이 자발반응(정반응)의 흡열반응이며, 고온에서 반응이 양호함을 나타내었다.