• Title/Summary/Keyword: Washing time

Search Result 673, Processing Time 0.026 seconds

Washing effect of fingermark contaminated with flammable liquids (인화성액체에 오염된 지문의 세척 효과)

  • Ho-Won, Jang;Ji-Yun, Kwon;Hyo-Mi, Kim;Seung-Ju, Yoo;Sungwook, Hong
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.237-241
    • /
    • 2022
  • The effect of washing fingerprints deposited on glass that were contaminated with a flammable liquid (gasoline, kerosene, diesel, and thinner) was studied by washing with hexane or heptane. The fingerprints were visualized using fuming cyanoacrylate, followed by basic yellow 40 staining. After comparing the washing effect, by dividing one fingerprint into four sections, it was confirmed that the ridge detail was damaged by dissolving the fingerprints in flammable liquid. As a result of washing fingerprints contaminated with flammable liquids using hexane or heptane, fingerprints contaminated with gasoline, kerosene, and thinner did not show a washing effect because the ridge detail was damaged at the time of contamination, and only fingerprints contaminated with diesel exhibited improved ridge detail quality. Because hexane and heptane washing damage the ridge detail, it was found that fingerprints contaminated with gasoline, kerosene, and thinner were better enhanced directly without the washing process. In addition, it was found that the amount of the washing solvent and contact time should be minimized when washing fingerprints contaminated with diesel.

Comparison of Detergency and Fabric Deformation between Ultrasonic and Home Laundry (초음파 세탁과 가정 세탁의 세척성과 직물변형 비교)

  • Nawon Hwang;Hae-won Chung;Kwang-Woo Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.3
    • /
    • pp.386-397
    • /
    • 2023
  • In this study, the efficacy of ultrasonic washing in cotton and wool fabrics was compared and evaluated against conventional washing in terms of cleaning properties and fabric deformation. Factors such as washing temperature, time, liquid ratio, and detergent concentration were kept varied, and the cleaning properties of sebum-soiled fabrics were assessed using different detergents such as alcohol ethoxylate, linear alkylbenzenesulfonate, and IEC 60456 Reference Detergent A*. In addition, the effects and emulsification power of enzymes and oxygen bleach were examined. To compare the cleaning properties with general washing, a launder-O-meter was used. To investigate fabric deformation during the washing process, the loosening test cloth, shrinkage test cloth, and mechanical strength test cloth were compared between ultrasonic washing machines and household drum washing machines. The results indicate that ultrasonic washing exhibits superior cleaning properties than launder-O-meter when the temperature is low and the washing time is short. Furthermore, there is less deformation and damage during the washing process. It was also observed that the activity of the detergent increases when ultrasonic waves are applied to the washing process. Considering the increasing tendency to pursue convenience and simplicity in clothing management as well as the anticipated commercialization of smart clothing with built-in electric circuits, ultrasonic laundry could serve as a new alternative to existing laundry methods.

A Study on Chemical Washing Mechanism by Flowing Film of Detergent/Water Solution (흐르는 세제혼합액막에 의한 화학적 세척 메커니즘에 대한 연구)

  • Jang, Choong-Hyo;Park, Chan-Youl;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.6 s.261
    • /
    • pp.499-506
    • /
    • 2007
  • This study aims to propose evaluation methods of chemical washing performance and estimate the washing capability by flowing detergent/water solution for application to home appliances such as dishwashers. Standard pollutant is stearic acid. A numerical study is also tried using a SIMPLER code. Preliminary experiments are performed by varying the concentration and temperature of the solution. From the pre-experiments, 10 minute pre-curing time is found to be necessary to remove the stearic acid. Stoichiometric ratio and detergent consumption coefficient of reaction between the detergent and stearic are estimated following a proposed method. Washing experiments of pollutant to compare with the numerical results are performed. The relative errors between the experimental and the numerical results with pre-curing time included are less than 7%. In conclusion, important mechanisms of chemical washing are revealed and methods of predicting washing performance are well established.

Establishment of Washing Conditions for Salad to Reduce the Microbial Hazard (샐러드의 미생물학적 위해 감소를 위한 세척 조건 확립)

  • Kim, Jeong-Weon;Kim, Soo-Hee
    • Korean journal of food and cookery science
    • /
    • v.21 no.5
    • /
    • pp.703-708
    • /
    • 2005
  • The purposes of this study were to establish washing conditions for vegetable salad to reduce the microbial hazard by using sodium hypochlorite solution and eventually to implement HACCP for salad processing. By using the salad production line of Shinkeum Co. located in Gwacheon, Gyunggi-do, salad samples were washed under several washing conditions (chlorine dip period, chlorine concentration, rinse time, etc.) to determine the most effective conditions. The original washing line consisted of 3 baths (100 ppm chlorine water dip, water rinse, and water rinse), each with a capacity of 100 L of tap water and 5 kg of salad. First, the salad samples were washed with 100 ppm of sodium hypochlorite solution for various dip times (3, 6, 9, 12 min); however, only a 1 log- or less-reduction in total microbial counts was achieved in all groups and the time of chlorine water dip was not a significant factor in reducing the microbial hazard. When another water bath was added before the chlorine water dip (4-bath washing), a 2 log-reduction in total microbial counts was achieved. This result suggested the importance of pre-dipping salad materials in water before chlorine treatment to reduce the organic load on the surface of the vegetables. Coliforms were not detected at all after washing. As the concentration of chlorine $(50{\sim}150\;ppm)$ and rinse time $(0.5{\sim}2\;min)$ increased, greater microbial reduction was achieved; however, physical damage of the salad was observed. Finally, the optimum washing conditions for salad were determined as 3 min-water dip, 3 min-chlorine (100 ppm) dip, 2 min-rinse, and 2 min-rinse.

The Soil Removal of Artificially Soiled Fabrics with Commercial Detergents at Various Washing Conditions (시판 세제를 사용하여 세척 조건에 따른 인공오염포의 세척성)

  • Chung, Hae-Won;Kim, Mi-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.9 no.6
    • /
    • pp.671-678
    • /
    • 2007
  • Formulations of compact and supercompact heavy-duty detergents, which are being used widely around the world, differ from those of conventional heavy-duty detergents. Significant differences in composition exist between the compact detergents and the conventional detergents. The compact detergents have a higher content of surfactants, oxygen bleach and enzymes than the conventional detergents. We have studied to find the most effective washing conditions of artificially soiled cloths with a commercial, supercompact, heavy-duty detergent and a drum type washing machine which is becoming the preferred type in Korea. Moreover, we have studied the washing performance with an impeller type washing machine, which has heretofore been the most popular type in East Asia. With the drum-type washing machine, washing performances improved as the washing temperatures went up and the washing times were lengthened. Though the rate of soil removal with a double recommended dosage was higher than with the recommended amount at $20^{\circ}C$, the effects of the higher dosage decreased as the washing temperatures increased. Finally, the washing performances with the two different dosages were the same at $60^{\circ}C$. The washing performances at $40^{\circ}C$ with the recommended dosage for 90 minutes were the same as with the double recommended dosage for 45 minutes. The soil removal efficiencies with the impeller-type washing machine were much lower than those of the drum-type washing machine. The reasons for this were the higher bath ratio that led to the lower concentration of wash liquor, the shorter washing time, and the lower washing temperature.

Research with Statistical Model to Analyze Efficiency of Heavy Metal Soil Washing (통계학적 모델을 이용한 중금속 토양 세척의 효율 분석에 관한 연구)

  • Oh, Sangyoung;Yoo, Jongchan;Baek, Kitae;Kim, Hanseung;Park, Jaewoo
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.14-24
    • /
    • 2018
  • In soil washing, there are many variables including types of reagent and contaminant, washing time, soil-liquid ratio, washing cycles, washing agent concentrations, and etc. To identify the most influencing factors on soil washing process, regression analysis was performed for eight single variables and five combined variables. A quantitative model that employs W/H (molar ratio of washing agent to heavy metal) as a major variable was established based on the regression. The validity of the model was demonstrated by conducting lab experiments with Cu, Pb, Zn, Ni and As-contaminated soils, and various washing reagents including acetic acid, citric acid, malic acid, oxalic acid, ethylenediamine tetraacetic acid (EDTA) and nitriloacetic acid (NTA). The washing efficiencies were compared with the EDTA washing data reported in the literature. The correlation between W/H and removal efficiency was analyzed after dividing data into two groups according to the heavy metal mobility.

The Effect of Washing Conditions on the Dimension and Mechanical Properties of Spandex Yarns (세척조건에 스판덱스사의 길이와 기계적 성질에 미치는 영향)

  • Chung, Hae-Won;Kim, Mi-Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1619-1626
    • /
    • 2005
  • The durability of a stretch fabric is mainly related to the change in the dimension and mechanical properties of elastomeric fibers during wearing and washing. In this study, we examined the effects of washing temperature, presoaking time and the number of washing cycles on the change in length, tenacity, elongation at break, and permanent elongation after six repeated cycles of $100\%$ extension and relaxation of spandex yams with varying fineness and with a different rate of extension during heat-set. The spandex yarns continued to shrink as the wash temperature and the number of wash cycles increased. In addition, the finer spandex yams decreased in length more than the thicker yams. The increase in temperature and presoaking time tended to cause a slight decrease in the tenacity and elongation at break of the spandex yarns. Permanent elongation of the spandex yams also increased as the temperature, presoaking time and the number of washing cycles increased. Moreover, an extended presoaking time followed by washing at $40\%$ like repeated washing cycles showed the great increase in the permanent elongation of spandex yams. The thinner spandex yin had a better elasticity than the thicker one, since the former had a lower permanent elongation percentage than the latter. Based on the DSC thermograms, the melting points of the spandex yarns after washing were almost the same as those of the spandex yarns before washing.

A Study on the Pet Soil Removal Effect of Washing Conditions Using a Chemiluminescence Reaction (화학발광 반응을 이용한 세탁조건별 반려동물 오구 제거효과 연구)

  • Park, Jung-Eun;Lee, Jungsoon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.5
    • /
    • pp.840-851
    • /
    • 2021
  • In this study, we used a chemiluminescence reaction to investigate the removal effect of pet soil, such as dog blood, urine and feces. The soiled fabrics were washed with a standard laundry course of 30℃ and a washing time of 30 min and a pet care laundry course of 40-60℃ and a washing time of 100 min. The detergency was evaluated by the surface reflectance and chemiluminescence reaction (bloodstain detection by luminol test and urine-stain and feces-stain detection by UV blacklight test) before and after washing. The surface reflectance results did not show any difference in detergency for both courses, whereas the chemiluminescence reaction did. The detergency of the pet care course compared to the standard course was 101% according to the surface reflectance and 120% according to the chemiluminescence reaction. Therefore, residual stains not detected by surface reflectance can be evaluated through chemiluminescence reaction, and it was confirmed that pet stains can be managed more hygienically by washing for a long time at a high temperature.

Soil Washing Technology for Sr and Cs-contaminated Soil Near Nuclear Power Plants using Calcium and Potassium Based Solutions (칼슘 및 칼륨 용액을 이용한 원자력발전소 주변 스트론튬과 세슘 오염토양 세척기술 연구)

  • Song, Hojae;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.2
    • /
    • pp.76-86
    • /
    • 2022
  • Calcium (Ca) and potassium (K) were introduced to remove Sr and Cs in soil, respectively. Four factor and three level Box-Bhenken design was employed to determine the optimal washing condition of Ca- and K-based solutions, and the ranges tested were 0.1 to 1 M of Ca or K, L/S ratio of 5 to 20, washing time of 0.5 to 2 h, and pH of 2 to 7. The optimal washing condition determined was 1 M of Ca or K, L/S ratio of 20, washing time of 1 h, and pH of 2, and Ca-based and K-based solutions showed 68 and 81% removal efficiency for Sr and Cs, respectively in soil. For comparison, widely used conventional washing agents such as 0.075 M EDTA, 0.01 M citric acid, 0.01 M oxalic acid, and 0.05 M phosphoric acid were tested, and they showed 25 to 30% of Sr and Cs removal efficiency. Tessier sequential extraction was employed to identify the changes in chemical forms of Sr and Cs during the washing. In contrast to the conventional washing agents, Ca-based and K-based solutions were able to release relatively strongly bound forms of Sr and Cs such as Fe/Mn-oxide and organic matter bound forms, suggesting the involvement of direct substitution mechanism, probably due to the physicochemical similarities between Sr-Ca and Cs-K.

Remediation of Pb-Contaminated Soil by Soil Washing using Hdrochloric Acid (염산을 사용한 납 오염 토양의 토양 세척에 의한 정화)

  • Baek, Ki-Tae;Kim, Do-Hyung;Seo, Chang-Il;Yang, Jung-Seok;Lee, Jae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.3
    • /
    • pp.17-22
    • /
    • 2007
  • The feasibility of soil washing was investigated to remediate Pb-contaminated field soil. Hydrochloric acid was used as a washing agent. As mixing time increased from 5 min to 120 min, removal efficiency of Pb from contaminated soil increased from 69.3% to 81.9%. Two times washing with 0.2 M HCl showed 96% removal efficiency even at mixing time of 10 min. The Pb content in soil increased sharply as particle size of soil decreased, and removal efficiency was highly dependent on mixing time and temperature. Based on this result, acid washing technologies can be applied to remediate the Pb-contaminated soil used in this study.