• 제목/요약/키워드: Wall to Wall Connection/Joint

검색결과 45건 처리시간 0.022초

지하연속벽 수직시공이음부에 콘크리트 전단키를 형성하는 시공기술 (Construction Method for Forming Concrete Shear Keys at Vertical Construction Joints of Slurry Walls)

  • 이정영;김승원;김두기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.401-402
    • /
    • 2023
  • The shear connection of the vertical construction joint of a slurry wall by the concrete shear key has excellent structural performance and is economical and eco-friendly. However, technology for forming concrete shear keys in the underground is still underdeveloped. This paper proposes the development of the construction technology required to form a concrete shear key at the vertical construction joint of the slurry wall.

  • PDF

채널과 커플러를 사용한 모듈식 구조체 우각부 연결구조의 성능검증 실험 (Performance Test of Corner Rigid Joint for Modular Structure using Channel and Coupler)

  • 이준경;이종순;이성형;김희성
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2255-2262
    • /
    • 2015
  • 최근 저심도의 도시철도 시스템이 제안되어 지상고가 형식의 민원과 지하경전철 형식의 비경제성을 극복하기 위한 연구가 진행중이다. 본 연구에서는 저심도 지하구조물의 경제성과 시공성 확보를 위하여 가시설을 대체하는 프리캐스트 형식의 모듈식 구조체를 적용하기 위하여 영구 강성벽체와 상부 슬래브간 연결부 조인트에 대한 구조적 성능을 검증하고자 실내 재하실험을 수행하였다. 성능재하 실험결과, 가시설 대체 강성벽체와 상부 슬래브간 연결부 구조는 휨모멘트 전달구조임을 확인하였다. 특히 휨 지배를 받는 상부에서는 채널형태보다는 커플러 조합이 휨 저항 성능이 30%정도 증가하여 유리함을 확인하였으나, 성능 개선이 필요한 것으로 확인되었다.

Slip Form과 Deck Plate를 채용한 벽식 APT의 접합부 Detail개발의 기초적 연구 (The basic study of the detail development of the Wall-type APT joint using Slip Form and Deck plate.)

  • 이희두;박신;임남기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.127-132
    • /
    • 2003
  • The purpose of current study is about how to construct wall-type APT in slip form and Deck plate applied different connection of materials that wall and slab. A proposal construct's solution is using the continuous a binding string that the main of contents are slab or stairs which horizon structure part construction is joined the vertical structure part, new we Proposed of 2 solution that new technology development. We'll suggest that the development is in the construct of higher stories APT more better other construction method. We expect that the new method is good but we have many things to solute themes. Thus, we decided that this development contents are needed that correct structural investigation and constructor's security of speciality and through a fact construct, correct verification.

  • PDF

Studies on seismic performance of the new section steel beam-wall connection joint

  • Weicheng Su;Jian Liu;Changjiang Liu;Chiyu Luo;Weihua Ye;Yaojun Deng
    • Structural Engineering and Mechanics
    • /
    • 제88권5호
    • /
    • pp.501-519
    • /
    • 2023
  • This paper introduces a new hybrid structural connection joint that combines shear walls with section steel beams, fundamentally resolving the construction complexity issue of requiring pre-embedded connectors in the connection between shear walls and steel beams. Initially, a quasi-static loading scheme with load-deformation dual control was employed to conduct low-cycle repeated loading experiments on five new connection joints. Data was acquired using displacement and strain gauges to compare the energy dissipation coefficients of each specimen. The destruction process of the new connection joints was meticulously observed and recorded, delineating it into three stages. Hysteresis curves and skeleton curves of the joint specimens were plotted based on experimental results, summarizing the energy dissipation performance of the joints. It's noteworthy that the addition of shear walls led to an approximate 17% increase in the energy dissipation coefficient. The energy dissipation coefficients of dog-bone-shaped connection joints with shear walls and cover plates reached 2.043 and 2.059, respectively, exhibiting the most comprehensive hysteresis curves. Additionally, the impact of laminated steel plates covering composite concrete floors on the stiffness of semi-rigid joint ends under excessive stretching should not be disregarded. A comparison with finite element analysis results yielded an error of merely 2.2%, offering substantial evidence for the wide-ranging application prospects of this innovative joint in seismic performance.

Steel-Plate 매입형 합성 연결보의 접합부 상세에 따른 내진거동 (Seismic Behavior by Beams-Wall Connections depending upon Joint Details of Embedded Steel-Plate Composite Coupling Beams)

  • 주재형;채승윤;김선규;김우재;전호민;박효선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.130-133
    • /
    • 2006
  • Owing to Higher story tendency and ceiling hight restriction of recent times, even though the depth of Coupling Beam decreases the demand efficiency is coming to be high rather so it is the difficult to satisfy a demand efficiency with the actual existing RC/Steel condition. It has been researched a lot of methods as an alternative plan about these but designer cannot apply them for the reason ; the structure standard and theory background are not taking a triangular position. As accomplishing the test research about the beams-wall connections department of steel-plate composite coupling beams from the research in the study it examines closely the beams-wall connections conduct quality and tries to provide the fundamental data for reasonable and optimum connection department designs. It knows that connection fixation degree and composite conduct degree of member part together become the important variable showing an energy dissipation ability in Test result.

  • PDF

반복 횡하중을 받는 프리캐스트 대형 콘크리트 판구조의 이력특성에 관한 실험적 연구 (Hysteretic Behavior of Precast Concrete Large Panel Structures Subjected to Horizontal Cyclic Loading)

  • 서수연;이원호;이리형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.253-260
    • /
    • 1999
  • Main objective of this study is to examine the hysteretic behaviors and to evaluate the capacity of precast concrete (PC) large panel structures simulated from the prototype of 15-story building, Two 1/2 scaled precast concrete wall specimens and one monolithic reinforced concrete specimen were designed and tested under the cyclic loading conditions. The main parameter of test specimens in PC large panel structure is the type of details for vertical continuity of vertical steel in horizontal joint. Also the behaviors of PC large panel structures are compared with that of monolithic reinforcement concrete wall structure. From the results, the stiffness and energy dissipation ratio of the precast concrete specimens are shown little bit lower than those of monolithic reinforced concrete specimen. In the PC large panel structures, the specimen connected vertically by welding (strong connection) showed higher strength than that of the specimen connected vertically by joint box. However the failure pattern of the former showed more brittle than that of the latter due to the diagonal compressive failure of wall panels.

  • PDF

강재 접합용 고전단 링앵커의 형상 개발과 전단실험 (Shape Decision and Shear Experiment of High-Shear Ring Anchor for Steel-Concrete Connection)

  • 전상현;김문길
    • 도시과학
    • /
    • 제7권2호
    • /
    • pp.29-36
    • /
    • 2018
  • The demand for reinforcement in accordance with remodeling, seismic retrofit, and change of use of the existing structure is increasing. Originally, shear wall new and extension method has been adopted a lot as seismic retrofit methods. Recently, dry seismic retrofit method that uses structural steel is mostly adopted in order to minimize spatiotemporal aspect and underpinning that occurs when a construct shear wall. We redesigned the form of old and new concrete joint high-shear ring anchor that was developed according to recent reinforcement method and determined construction method. Shear tests were performed on High-Shear Ring Anchor for steel-concrete connection. Comparison with 4 tests shows that the average of test-to-prediction ratios is 1.01.

프리캐스트 콘크리트 벽체 수직접합부의 광폭형 연결방식 개발 (Development of Wide Connection Method for Vertical Joints of Precast Concrete Walls)

  • 최은규;신영수
    • 콘크리트학회논문집
    • /
    • 제21권5호
    • /
    • pp.549-556
    • /
    • 2009
  • 이 연구에서는 프리캐스트 콘크리트 구조시스템에서 기존에 사용되고 있는 벽체의 수직접합부의 시공 및 문제점을 최소화하기 위해 접합부의 폭을 100 mm에서 150 mm로 증가시키고 연결방식을 3가지로 하여 구조적 성능 및 적용성에 대해 분석하였다. 또한, 해석적으로 구조적 성능을 파악하기 위해 비선형 유한 요소 해석법으로 분석하였다. 분석 결과, 광폭형 연결부를 가진 접합부를 적용하였을 때, PC벽체에 가해지는 하중을 더 효율적으로 철근이 분담하여 내력이 증가하고 연성적인 거동을 하는 것으로 나타났다. 또한, 접합부 루프근의 단면적이 커질수록 그리고 철근 개수가 증가할수록 최대내력이 증가하며 광폭형 접합부 형식 중에 용접형-링형-C형의 순서로 내력이 큰 것으로 나타났다. 용접형의 경우 현장조건에 따른 변화가 발생할 수 있으므로 광폭형 연결 부위를 링형 접합부로 하는 것이 안정적인 거동을 하며 현장 용접의 철저한 품질관리가 필요하다.

리기다 소나무 정각재를 사용한 목재옹벽의 직결나사못 접합부 내력 성능 평가 (Strength Performance Evaluation of Threaded Nail Joints of Wooden Retaining Wall Using Pitch Pine (Pinus rigida Miller) Square Timber)

  • 송요진;김건호;이동흡;황원중;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제39권1호
    • /
    • pp.53-59
    • /
    • 2011
  • 시험 시편은 1개의 횡목과 2개의 종목이 직결나사못 2개로 연결된 접합부(Type-A)와 2개의 횡목과 2개의 종목이 4개의 직결나사못으로 연결된 접합부(Type-B)를 제작하였다. Type-B를 보강하기 위하여 횡목간의 연결부를 끝면거리 5D로 반턱이음하여 2개의 직결나사를 사용한 접합부(Type-C), 끝면거리 10D로 반턱이음한 접합부(Type-C1)와 끝면거리 10D, 직결나사 3개를 사용한 접합부(Type-C2)를 제작하였다. 압축형 전단 내력 시험결과 Type-B의 내력을 기준으로 Type-B를 보완한 Type-C는 약 30% 감소하였고, Type-C에서 끝면거리를 증가시킨 Type-C1은 Type-B와 비슷한 내력을 보였으며, Type-C1에서 직결나사못의 개수를 3개로 증가시킨 Type-C2는 Type-C1과 비교하여 1.28배 내력을 나타냈다. 기존 정각재를 이용한 옹벽의 접합부 중 긴 횡목과 짧은 횡목이 2개의 종목과 연결되는 접합부는 내력이 저하되기 때문에 이를 대체하기 위하여 실험을 실시하였다. 따라서 Type-B를 Type-C2로 대체한다면 옹벽 시공시 직결나사못에 의한 목재의 할렬, 파단과 시공시간이 줄어들고 접합 내력이 증가할 것으로 기대된다.

전통 목조 프레임구조의 지진하중에 대한 거동 특성 (Behavior of Traditional Wood Frames Under Earthquake Loading)

  • 홍성걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.304-313
    • /
    • 2000
  • This study presents the behavior of traditional wood structures of national heritage under earthquake loadings. A series of experimental program for four wood frames was performed to investigate characteristics of initial stiffness, behavior after ultimate loads, and hysteretic behaviors. The frames consisted of columns with a lintel by special joint and a bare frame was infilled by a mud wall. A pushover est was aimed to estimate the range of ultimate rotation of connection as a pilot test for cyclic load tests. One of frames infilled by a mud wall showed a larger stiffness than those of bare frames due to a strut action in the diagonal direction. However, the post yielding stiffness of the infilled frame was not increased.

  • PDF