• 제목/요약/키워드: Wall panel

검색결과 437건 처리시간 0.025초

네팔 해비타트(HfH_Nepal) 생태주택 보급현황과 성능개선실험 연구 - 떠라이 평원지역을 중심으로 - (Experiment for the Performance Improvement of Eco House Provided by Habitat for Humanity Nepal(HfH_Nepal) - Case Study of Terai Plain Region, Nepal -)

  • 임윤택
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.103-112
    • /
    • 2013
  • The Federal Democratic Republic of Nepal(Nepal) is one of the poorest country in the world. People in Nepal are having lots of housing problems including the lack of housing provision. Even Habitat for Humanity Nepal (HfH_Nepal) has developed various programs to diffuse ecological housing, still there are many problems due to financial and technological shortage. The purpose of this study is to verify the effects of suggestion of performance improvement for HfH_Nepal eco house with introduction of the housing situation and efforts to provide sustainable housing by HfH_Nepal in Terai plain. Ideas on CGI sheet roof with poor insulation, double panel bamboo wall and adobe brick wall which can overcome structural and waterproof flaws of the thin single panel bamboo wall. The experiment result shows that both ideas adapted to adobe brick house reduces daily temperature range 50.8% and humidity adjust effect. For the effective provision of adobe brick house, compressive strength was tested for the bricks made with locally available fiber materials. Brick with jute displayed 41.1% betterment than plain brick with closest packing condition while coconut and straw showed 25.1% and 7.9% improvement respectively. Technical and economic problems brought up during the building and experiment process were listed and countermeasures established. This kinds of building prototype houses and experiments can improve the living conditions of people in developing countries with little supplement of resources. Furthermore, consideration of locally available and affordable material can help the social and ecological sustainability in the world.

전단벽의 전단성능 예측 모형 (Theoretical Models for Predicting Racking Resistance of Shear Walls)

  • 장상식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권4호
    • /
    • pp.96-105
    • /
    • 2002
  • 전단벽은 현대식 경골목조건축에서 바람이나 지진 등에 의한 측방하중에 대한 저항력을 제공하는 가장 중요한 요소 중의 하나이다. 전단벽에서 건물에 전달된 측방하중은 벽의 스터드와 덮개재료 사이의 못접합부를 통하여 덮개재료로 전달되고 덮개재료에 전달된 하중은 판재의 면전단력에 의하여 지지된다. 따라서 실제 전단벽에서 측방하중에 대한 저항력을 결정하는 가장 중요한 요소는 못접합부라고 할 수 있을 것이다. 이 연구에서는 스터드와 판재 사이의 못접합부에 대한 강성 및 강도를 측정하였으며 이 값들은 전단벽의 찌그러짐 저항력을 예측하는 이론모형의 입력자료로 사용되었다. 이론모형의 예측치의 정확성을 검증하기 위하여 판재 한 장으로 구성된 전단벽의 전단시험을 수행하였다. 못접합부의 강성은 스터드 부재의 섬유방향에 의하여 영향을 받았으나 판재의 방향은 거의 영향을 미치지 않는 것으로 나타났다. 전단하중 하에서 못접합부나 전단벽의 거동은 3개의 직선구간으로 나나낼 수 있었으며 이론모형 I보다 이론모형 II의 예측치가 더 정확하였다.

프리컷 방식을 적용한 기둥-보 공법의 수평전단내력 (Shear Performance of Post and Beam Construction by Pre-Cut Process)

  • 황권환;박주생;박문재
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권6호
    • /
    • pp.1-12
    • /
    • 2007
  • 한국형 목조건축 실현 및 국내산 조림 낙엽송의 유효 이용을 위해 전통목구조에 있어 널리 사용되는 짜맞춤 공법을 응용한 기계 프리컷 방식으로 드리프트 핀 접합한 낙엽송 집성재 기둥-보 곡법에 대해 수평전단내력성능을 평가하였다. 기계 프리컷 가공된 부재로부터 기둥-보 공법으로 이루어진 골조구조체, 골조와 경골목구조 공법을 혼용한 벽구조체에 대해 현행 KS F 2154 기준에 의거하여 수평전단반복시험을 행하여 얻어진 하중-변위로부터 전단 변형과 전단력의 관계를 산출하였다. 무재하식 수평전단 가력에 의해 최대 전단내력을 골조구조체에서 1.9 kN/m, 벽구조체에서 9.7 kN/m, 전단강성계수는 167 kN/rad, 8198 kN/rad로 각각 나타났다. 골조구조체는 벽구조체에 비해 하중 분담률이 20% 정도, 강성에 있어서는 2% 정도로 나타났으며, 전단내력벽의 최대 전단내력은 골조에 비해 상대적으로 변형성능이 낮게 나타났다. 일본건축학회의 벽배율 산정법에 의한 전단내력벽의 벽배율은 1.5로 산출되었다. 전단내력벽의 전단성능 향상을 위해서는 주각부 및 기둥-보, 못과 면재에 대한 차후 검토와 수평전단 가력법에 대한 검토가 필요한 것으로 판단되었다.

샌드위치패널 창고 소방대원 현장활동 대응력 제고 방안 (A Study on the Improvement of Field Activity for Firemen in Sandwich Panel Warehouse)

  • 안병국;김운형;양소진;함은구
    • 한국재난정보학회 논문집
    • /
    • 제16권3호
    • /
    • pp.421-429
    • /
    • 2020
  • 연구목적: 본 연구는 샌드위치패널 창고의 화재예방 및 현장소방대응력 제고를 위한 단계별 대응방안 제시를 목적으로 한다. 연구방법: 화재현장 관련 소방관 인터뷰와 소방전문가의 자문 및 방호성능 실험을 수행하여 현장대응력 강화를 위한 요소별 대책을 도출하였다. 연구결과: 창고 소방안전관리자용 화재안전관리 체크리스트 및 샌드위치패널 창고의 벽 방호용 스프링클러 설치기준을 제시하였다. 아울러 현장출동 소방관을 위한 샌드위치패널 창고 화재적용 표준작전절차를 수립하였다. 결론: 본 연구를 통하여 가연성 구조 창고의 화재 예방, 방호 및 진압에 대한 단계별 화재안전대책을 구축하였다.

산사태 억지벽체공법에 관한 연구 (A Study on the Stabilizing Method against Landslide using Slide Suppressor Wall)

  • 김홍택;강인규;염경섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 학술발표집 신소재, 신기술에 의한 사면안정이론과 시공사례
    • /
    • pp.94-110
    • /
    • 1994
  • 본 연구에서는 Wright 등이 제안한 산사태 억지벽체공법에, nailing system을 추가한 새로운 형태의 사면보강공법을 제시하였다. 이를 위해, nail로 보강된 콘크리트판넬에 작용하는 토압산정법의 제시 및 억지말뚝 해석법의 정립 등이 이루어 졌다 또한 제시된 토압산정법을 토대로 nail의 효율적인 배치형태 및 설치각도 등에 대한 분석과, 콘크리트 판넬 및 억지말뚝 등으로 구성된 억지벽체의 최적설치위치에 관한 FLAC 프로그램 분석 등이 수행되었다. 이외에도 본 공법의 시공개요를 제시하였으며, 아울러 설계예를 통한 Wright 등의 제안방법과의 비교, 억지말뚝 상호간섭작용의 영향검토 등이 포함되었다.

  • PDF

The Study on Thermal Performance Evaluation of Building Envelope with VIPs

  • Jeon, Wan-Pyo;Kwon, Gyeong-Jin;Kim, Jin-Hee;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: The energy consumption in buildings has continuously increased in some countries and it reaches almost 25% of the total energy use in korea. Therefore there are various efforts to minimize energy consumption in buildings, and the regulations on building envelope insulation have been tightened up gradually. To satisfy the building regulation, the use of vacuum insulation panels(VIPs) is increasing. VIP is a high performance insulation materials, so that it can be thinner than conventional insulation material. When VIP is applied in a building, it may cause thermal bridge, which occurs due to very low thermal conductivity compared to other building materials and the envelope of VIPs. Method: This study designed the capsulized VIPs using conventional insulation for reduction of the thermal bridge. Then designed VIPs were applied to a wall. The linear thermal transmittance and the effective thermal conductivity were analyzed by HEAT2 simulation program for two dimensional steady-state heat transfer. The result compared with a wall with non-capsulized VIPs. Result: It analyzed that the wall with capsulized VIPs had lower linear thermal transmittance and reduced the difference of the effective thermal transmittance with one dimensional thermal transmittance compared to that of the wall with non-capsulized VIPs.

AC PDP의 addressing 시 3전극 상에서의 벽전하량 계측 (The Measurement of the Wall Charge on the Three Electrodes in the Addressing Period of ac PDP)

  • 이기범;김동현;강동식;박차수;조정수;박정후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.103-107
    • /
    • 2000
  • The relationships between driving voltage and the wall charge distribution in the address period of surface discharge type AC Plasma Display Panel have been investigated. The quantity of wall charge on each electrode are detected simultaneously from the electrode current after applying only one addressing discharge pulse. The wall charge Qy on the scan electrode Y is nearly the sum of Qx on the address electrode X and Qz on the sustain electrode Z. The Qy increased with the driving voltage regardless of the kind of electrode, whereas the address time Td decreased, Qz and Qy are increased considerably with the blocking voltage Vz, whereas Qx is decreased. The increase rate of Qx, Qy and Qz for increase in Vz was $-13{\times}10^{-2}$ (pc/Vz), and $60{\times}10^{-2}$ (pc/Vz) and $70{\times}10^{-2}$(pc/Vz), respectively.

  • PDF

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (I): Experimental study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.399-408
    • /
    • 2017
  • This paper experimentally studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Four beam-to-wall connection specimens with short and long embedded steel columns are tested under monotonic and cyclic loads, respectively. The influence of embedment length of columns on the failure mode and performance of connections is investigated. The results show that the length of embedded steel columns has significant effect on the failure mode of connections. A connection with a long embedded column has a better stiffness, load-bearing capacity and ductility than that of a short embedded column. The former fails due to the shear yielding of column web in the joint panel, while failure of the latter is initiated by the yielding of horizontal reinforcement in the wall due to the rigid rotation of the column. It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility.

연직접합(鉛直接合)의 강성(剛性)이 프리케스트 전단벽(剪斷壁)의 구조적거동(構造的擧動)에 미치는 영향(影響) I. 하중조합(荷重組合) 1에 대하여 (Influence of the stiffness of Vertical Joints on the Behaviour of Precast Shear Walls. Part1. Load Case 1)

  • 박경호
    • 산업기술연구
    • /
    • 제3권
    • /
    • pp.103-116
    • /
    • 1983
  • Recent developments in multi-storey buildings for residential purpose have led to the extensive use of shear walls for the basic structural system. When the coupled shear wall system is used, joined together with cast-in-place concrete or mortar (or grout), the function of the continuous joints is a crucial factor in determining the safety of L.P. Precast concrete shear wall structures, because the function of the continuous joints(Vertical wall to wall joints) is to transfer froces from one element(shear wall panel) to another, and if sufficient strength and ductility is not developed in the continuous joints, the available strength in the adjoining elements may not be fully utilized. In this paper, the influence of the stiffness of vertical joints(wet vertical keyed shear joints) on the behaviour of precast shear walls is theoretically investigated. To define how the stiffness of the vertical joints affect the load carrying capacity of L.P.Precast concrete shear wall structure, the L.P.Precast concrete shear wall structure is analyzed, with the stiffness of the vertical joints varying from $K=0.07kg/mm^3$(50MN/m/m) to $K=1.43kg/mm^3$(1000MN/m/m), by using the continuous connection method. The results of the analysis shows that at the low values of the vertical stiffness, i.e. from $K=0.07kg/mm^3$(50MN/m/m) to $K=0.57kg/mm^3$(400MN/m/m), the resisting bending moment and shearing force of precast shear walls, the resisting shearing force of vertical joints and connecting beams are significantly affected. The detailed results of analysis are represented in the following figures and Tables.

  • PDF

컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성 (Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제21권2호
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.