• 제목/요약/키워드: Wall conditioning

검색결과 402건 처리시간 0.022초

좁은 휜이 달린 경사면을 흐르는 리튬브로마이드 수용액 흡수기에서의 열 및 물질전달 (Coupled Heat and Mass Transfer in Absorption of Water Vapor into LiBr-$H_2O$ Solution Flowing over a Finned Inclined Surface)

  • 조은준;서태범
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.860-867
    • /
    • 2001
  • Absorption of water vapor into LiBr-$H_2O$ O solution flowing over a finned inclined surface is numerically investigated. The momentum, energy, and diffusion equation are numerically solved using a finite difference method. The four different shapes of the wall surfaces are considered to find the best surface for absorption assuming that the wall temperature and the surface tension are constant. The effects of the fin interval and Reynolds number are investigated. Based on the numerical results, it is known that the parabolic surface shows better absorption performance than the other surfaces, and that water vapor absorption increases gradually with decreasing the fin interval.

  • PDF

오비터 공기 압축기 성능해석 (Performance Analysis of an Orbiter Air Compressor)

  • 김현진;조광명;고원
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.754-763
    • /
    • 2005
  • This paper introduces a new concept compressor in which piston orbits in the cylinder having an annular space formed between two concentric circular walls. In this configuration, two gas pockets are formed with $180^{\circ}$ phase difference: one between the wrap of the orbiting piston and the inner cylinder wall and the other between the piston wrap and the outer cylinder wall. This alternating feature of gas compression and discharge processes yields several advantages such as low torque variation and low gas pulsation. Computer simulation program has been developed to evaluate the compressor performance. The volumetric, adiabatic, and mechanical efficiencies of the orbiter compressor are calculated to be $85.6\%,\;97.2\%,\;and\;95.2\%$, respectively, when it is used as an air compressor.

생애비용 분석을 통한 외벽 및 단열재료 종류별 냉동냉장창고 외피의 적정 단열두께 산정 (Optimized Insulation Thickness of the Refrigerated Warehouse with Different Envelope Structures and Insulation Materials by L.C.C. Analysis)

  • 강승희;구보경;황혜주;석호태;안홍섭;송승영
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.372-381
    • /
    • 2003
  • This study aims to find out the optimized insulation thickness of refrigerated warehouse with different envelope structures (RC and PC wall) and insulation materials (urethane and icynene). Each of them is compared according to the thickness of insulation (100, 150, 200 mm/50 or 250 mm) and the temperature of cold storage room (0, -6, -15$^{\circ}C$). As results, it is proved to have the best economical efficiency in life cycle cost when PC wall with thickness of 100 mm (0 and -6$^{\circ}C$) and 150 m (-15$^{\circ}C$) urethane, respectively, are applied.

수평원관군상(水平圓管群上)의 이원흡수용액유동(二元吸收溶液流動)에 의(依)한 전달흡수특성(傳達吸收特性) (Absorption of Water Vapor into an Absorbing Binary Liquid Film Falling over a Horizontal Tube Bank)

  • 김석현;김영인;서석청;황동곤
    • 대한설비공학회지:설비저널
    • /
    • 제17권5호
    • /
    • pp.583-589
    • /
    • 1988
  • Condensation of water vapor into an absorbent liquid of LiBr-water solution falling over a bank of water cooled horizontal tubes was investigated theoretically. The governing conservation equation for a re-defined physical transport phenomena were solved numerically using a finite difference method. Raw parameters were used in this study, since reliable experimental data is required prior to a dimensionless parametric study. The average values of wall heat transfer coefficient and interfacial absorption rate were defined to see the system performance. Other parameters include tube diameter, streamwise coordinate (and number of tubes in row), mass flow rate, and the wall temperature. The effects of these quantities on the absorption processes and suggestions for a rational system design have been presented.

  • PDF

간이 에너지 계산법과 동적 열부하 계산법의 비교 연구 (A Comparison of the ASHRAE Simplified Energy Analysis Procedure with the HASP/ACLD Results)

  • 김두천;최진희;원영수
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.210-218
    • /
    • 1989
  • The ASHRAE Simplified Energy Analysis Procedure using the Modified Bin Method(SEAP) is compared with the hourly calculation program, HASP/ACLD. The HASP/ACLD model office building with VAV system in Seoul is used as the basis for comparison. And the parameters considered are glass to wall area ratio and internal heat gains. The results show that SEAP predictions of annual energy use agree with HASP/ACLD predictions within 5% deviation. But there is a large difference in cooling and heating energy as glass to wall area ratio is varied. The SEAP cooling energy is 65-85% and the heating energy is 104-160% of the HASP/ACLD results. This is probably due to the solar heat gain data. the data related to the SEAP must be developed prior to use it.

  • PDF

적층형 판 열교환기의 U턴부 유동해석 (An analysis of fluid flow In U-bend area of laminated plate heat exchanger)

  • 이관수;박철균;정지완
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.348-357
    • /
    • 1998
  • The flow characteristics inside U-bend tube of the laminated plate heat exchanger were numerically investigated. The behavior of fluid flow, and the variations of the faulty area and friction factor are examined according to the distance between the span and the wall and the diameter of the round attacked to the end of span. The results show that the diameter(d) of the round attached to the span is mainly associated with the smooth circulation of fluid flow rather than the size of faulty area and the friction factor. As the distance($\ell$) between the span and the wall decreases, the faulty area decreases, however the friction factor dramatically increases. It is also found that one can obtain a good result in the view of the flow characteristics and pressure drop at d=7.5mm and $\ell$=30.5mm.

  • PDF

수직관 내 초임계상태 물의 천이상태 대류열전달현상에 관한 연구 (A Study on the Transient Convective Heat Transfer for Supercritical Water in a Vertical Tube)

  • 이상호
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1095-1105
    • /
    • 2005
  • Numerical analysis has been carried out to investigate transient turbulent convective heat transfer in a vertical tube for supercritical water near the thermodynamic critical point. Heat transfer and fluid flow in the tube we strongly coupled due to the large variations of thermodynamic and transport properties such as density, specific heat, and turbulent viscosity. As pressure in the tube approaches to the critical pressure, the properties variation with time becomes larger. Heat transfer coefficient rapidly decreases along the tube near the pseudocritical temperature at the tube wall for $P_R<1.2$. Stanton number variation with time is largely reduced in the region of gas-like phase in comparison with Nusselt number. Turbulent viscosity ratio close to the wall increases near the pseudocritical temperature and it gradually decreases with time.

로타리 베인 공기압축기의 성능에 관한 수치해석 (Analytical Study on the Performance of a Rotary Vane Compressor)

  • 김현진;남보영;이경용
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.351-358
    • /
    • 2006
  • This paper presents analytical results of a rotary vane compressor performance when the compressor is used for air supply from underwater. Compression characteristics such as pressure and temperature in a compression chamber are analyzed. Volumetric and adiabatic efficiencies are calculated. Vane dynamics are also performed to give reaction forces on the vane from the cylinder inner surface and from vane slots. Compressor efficiency is about 34.9%, and about 55% of the compressor loss is produced by the friction between the vane nose and the cylinder wall. Volumetric efficiency is about 79.5%, and indicated efficiency is about 77.1%, which are comparable to other displacement type compressors. When roller was introduced between housing inner wall and vane tips, mechanical efficiency could be improved by as much as 24.9%, depending on the roller friction.

수직동심환상관에서 반경방향 보이드율의 변동특성 (Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권5호
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

Frequency Response Characteristics of Air-Cooled Condenser in Case of Inputting Various Disturbances

  • Kim, Jae-Dol;Oh, Hoo-Kyu;Yoon, Jung-In
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권1호
    • /
    • pp.14-28
    • /
    • 2000
  • The frequency response characteristics of a condenser were numerically studied for the control of refrigeration and air conditioning systems. The important parameters, such as the refrigerant flow rate, refrigerant temperature, air velocity, and air temperature at the condenser inlet, were analyzed. Superheated vapor, two phase, and subcooled liquid domain in condenser can be described by using the energy balance equation and the mass balance equation in refrigerant and tube wall, the basic equation for describing the dynamic characteristics of condenser can be derived. The transfer function for describing dynamic response of the condenser to disturbances can be obtained from using linearizations and Laplace transformations of the equation. From this transfer function, analytical investigation which affects the frequency responses of condenser has been made. Block diagrams were made based on the analytic transfer function; dynamic responses were evaluated in Bode diagrams on the frequency response. Through this study, it became possible that the information about the dynamic characteristics of air-cooled condenser is offered. The results may be used for determining the optimum design parameters in actual components and entire systems. Also, the mathematical models, frequency response may be used to help understanding, evaluate optimum design parameters, design control systems and determine on setting the best controller for the refrigeration and air-conditioning systems.

  • PDF