• 제목/요약/키워드: Wall conditioning

검색결과 402건 처리시간 0.034초

건축자재 마감구성에 따른 실내공기오염물질 방출특성에 관한 연구 (A Study on the Indoor Air Pollutants Emission Characteristics by Composed Building Materials)

  • 박진철;이언구;유형규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2005
  • Building parts of Multi-Family Houses are consisted of several building material assembly. Therefore, after selecting building materials with test result of emission intensity and their feature, composed building materials are made equally with actual construction methods, and experimented emission intensity. 7 days after experiment, formaldehyde emission intensity appeared low in an order of Tile Wall, Wood Flooring, Wallpaper, Reum Flooring, Silk Wallpaper, and 20 days after experiment, TVOC emission intensity appeared low in an order of Tile Wall, Reum Flooring, Silk Wallpaper, Wood Flooring, Wallpaper. There was a clear difference in TVOC emission intensity according to kind of building materials. Composed building materials that weight per unit area is big and omission intensity is high, they effect continuously to indoor air because decrement is small.

  • PDF

초단열 슈퍼윈도우의 단열성능 실측과 시뮬레이션 비교 분석 (A Comparative strudy on the Insulation Performance of the Super Window by Actual Survey and Simulation)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.231-235
    • /
    • 2009
  • According to flow of energy, the loss occurs through walls, roofs, windows and so on. Among these case, most of the loss that is about 45% occurs through windows. windows's U-value is six times higher than wall's one according to Building code, so the loss through windows accounts for very much rates. Currently, Exterior wall's U-value about building envelope is 0.35~0.58W/ mK, but windows's one is 3.3W/ mK. It means that the loss through windows occupy very much amounts relatively. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems Like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. Therefore, on this paper, Thermal Performance was evaluated through actual test about high insulation Super Window which can improve thermal performance and the Simulation result was compared with actual resul by using Simulation program WINDOW and THERM.

  • PDF

그루브형 히트파이프를 갖는 이중진공관형 태양열 집열기의 열전달특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Characteristics of a Grooved Heat Pipe for Solar Collector)

  • 김병기;정경택;장환영;서정세
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.965-969
    • /
    • 2006
  • This study investigated heat transfer characteristics between absorber and heat pipe used to extract heat from concentric evacuated tubular collectors. In order to experiment, T-type thermocouples are attached to a evaporator of heat pipe and absorber of inner tube. A wall temperature distribution of absorber and heat pipe were carried out by experimental method under actual various ir-radiance and outdoor conditions. As a result, As to increase an irradiance, a wall temperature of absorber and heat pipe is gradually increased. The heat pipe was required about 20min to obtain steady state operation after start up and operates stable during various irradiance conditions. And the collector efficiency was about $50{\sim}70%$ when a mass flow rate is about $1.3{\ell}/min$.

  • PDF

동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석 (Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell)

  • 강은철;박용대;이의준;윤태권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

Hydro-Reactive 엔진의 산화제 분사각도에 따른 연소특성에 대한 연구 (Effects of Oxidizer Inject Angle on Combustion Characteristics in Hydro-Reactive Engine)

  • 원종한;이성남;백승욱;황창환;김경무
    • 한국연소학회지
    • /
    • 제19권2호
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, the variation of the flow field in Hydro-reactive engine combustor was numerically studied through 2-dimensional axisymmetric model with aluminum and heated water vapor. For calculating all velocity fields, compressible Navier-Stokes equation was used with Pre-conditioning. AUSM+up(p) method was used to exactly calculate mass flow in the control volume. As using SST model that is a turbulent model, the result had high accuracy for free stream and the flow near the wall. The effects of the temperature, variation of the flow field and distribution of chemical products on inject angle of heated water vapor were studied.

레스토랑의 색채환경계획을 위한 기초적 연구 -식사공간을 중심으로- (A Basic Study for Environmental Color Planning of Restaurant)

  • 홍영란
    • 한국실내디자인학회논문집
    • /
    • 제3호
    • /
    • pp.10-17
    • /
    • 1994
  • Restaurant is a settign for est and social intercousrse fo rpeople in the cities, and is essential to provide its users with pleasant and comfort space. Color is used as a design tool which has most powerful effect to change the nature of a space and atmosphere, As a basic study for desirable environmental color for restaurant, this is studied mainly on the following discussion points. 1) Inportance of environmental color and its role in accordance with space characteristics as restaurant. 2) The psychological effects of color in the clinetes, color conditioning of the dining ares, problem of change in the appearance of color in the selection of materials and color harmony of total environments. 3) Prior to color planning in detail , the nature and characteristics each restaurant contains and their correlation with various locational , physical , social environmental , human variables have been analyzed. And the total atmosphere of the dining area as a place where the clients finally stay has been dealt with various visual , environmental and functional problems of color about fixed elements such as the wall. the floor, the ceiling and semifixed elements such as tables, chairs, etc.

  • PDF

일정온도로 가열되는 원통 형상 슬러지 박막의 건조에 대한 3차원 해석 (Three-Dimensional Analysis on Drying Process of a Cylindrical Thin Film Layer of Sludge under Uniform Heating)

  • 이공훈;김욱중
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1326-1331
    • /
    • 2009
  • Drying process in the cylindrical thin film layer of sludge with the thickness less than a few millimeters has been investigated. Thin film drying is specially designed and used to dry the viscous materials like sewage sludge. The thin film layer of sludge is dried on the metallic cylindrical surface through which thermal energy is supplied to the layer during drying. The wall temperature is assumed to be constant during drying in the present study for the simplification. In order to solve the equations, the mass transfer rate on the drying surface should be determined. The mass flux of evaporated water vapor on the surface is estimated with the formulation given in the literature. The effect of some physical parameters on drying has been examined to figure out the drying characteristics of the sludge layer.

  • PDF

고기밀.고단열 문의 성능평가 및 기준설정에 관한 연구 (Study on the Test Methods and Performance Criterion of High Insulated Door)

  • 강재식;최경석;김경우;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.618-622
    • /
    • 2009
  • About a Structure is performance insulation include air-tight is fundamental performance for energy-saving. The Apartment house of permission balcony enlarged to increase the requirement of market of high-effective door. Since 2001 years the window and wall of insulation performance stronger frailty than keep up performance insulation that increase influence building energy generated heat loss at door. In study on presentation that high-insulation, air-tight door about experimental method and performance standard.

  • PDF

유리성능에 따른 커튼월건물의 에너지절약효과에 대한 연구 -표준건물 에너지소비와의 비교분석을 중심으로- (A Study on a Efficiency of Glazing for Energy Reduction of Curtain Wall Buildings)

  • 이용준;정광섭;오보환;강재식;최경석;이득호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.114-119
    • /
    • 2009
  • This study has been conducted to describe the establishment of national measures to reduce world energy consumption and $CO_2$ Emission. Particularly, Reductions in energy consumption from building operation is the most important part to achieve these national objectives. Element to evaluate the quantitative effects of these systems by having rationalized regulation and operation is essential, when planning for building energy reduction design. USGBC(US Green Building Council) have operated sustainable assessment method called LEED, which introduces baseline performance and evaluation direction for building simulation techniques. This research analyzed Quantitative assessments of the building energy consumption and analyzed baseline figures to provide comparative analysis with standard building settings.

  • PDF

파이프 내부의 유동소음에 관한 연구 (A study on the fluid noise in the pipe)

  • 황기수;최명진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1435-1439
    • /
    • 2009
  • Drainage noise with making think about what they do disturbs neighborhoods live under source of noise. elbow pipe built in the house. the general elbow pipe has a rectangular elbow because of easiness when the plan set up or executing. therefore, free falling fluid impacts on the wall of the elbow pipe almost at one point. in this paper, to disperse the potential energy, the shock decentralizes from tiny area to large area. And It is considered how the characteristics change according to the noise of transformed shape of pipe, then researched the effectiveness of transformed pipe configuration.

  • PDF