• Title/Summary/Keyword: Wall break

Search Result 116, Processing Time 0.03 seconds

The Behavior of Impinging Spray by Piston Cavity Geometry (PistonCavity 형상에 따른 충돌분류의 분무거동)

  • 이상석;김근민;김봉곤;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.211-219
    • /
    • 1996
  • In a small high-speed D. I. diesel engine, the injected fuel spray into the atmosphere of the high temperature is burnt by go through the process of break up, atomization, evaporation and process of ignition. These process are important to decide the emission control and the rate of fuel consumption and out put of power. Especially, in the case of injected fuel spray impinging on the wall of piston cavity, the geometry of piston cavity gives great influence the ignitability of injected fuel and the flame structure. Ordinary, the combustion chamber of driving engine have unsteady turbulent flow be attendant on such as the change of temperature, velocity and pressure. So the analysis of spray behavior is difficult. In this study, the spray was impinged on the wall of 3 types of piston cavity such as Dish, Toroidal, Re-entrant type, in order to analyze the combustion process of impinging spray precisely and systematically. And hot wire probe was used for analyze non-steady flow characteristics of impinging spray, and to investigate the behavior of spray, the aspects of concentration c(t), standard deviation σ(t) and variation factor(vf) was measured with the lapse of time.

  • PDF

On Relevant Ramberg-Osgood Fit to Engineering Non-Linear Fracture Mechanics Analysis (정확한 비선형 파괴역학 해석을 위한 Ramberg-Osgood 상수 결정법)

  • Huh, Nam-Su;Kim, Yun-Jae;Choi, Young-Hwan;Yang, Jun-Seok;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1571-1578
    • /
    • 2003
  • This paper proposes a robust method for the Ramberg-Osgood(R-O)fit to accurately estimate elastic-plastic J from engineering fracture mechanics analysis based on deformation plasticity. The proposal is based on engineering stress-strain data to determine the R-O parameters, instead of true stress-strain data. Moreover, for practical applications, the method is given not only for the case when full stress-strain data are available but also for the case when only yield and tensile strengths are available. Reliability of the proposed method for the R-O fit is validated against detailed 3-D Finite Element (FE) analyses for circumferential through-wall cracked pipes under global bending using five different materials, three stainless steels and two ferritic steels. Taking the FE J results based on incremental plasticity using actual stress-strain data as reference, the FE J results based on deformation plasticity using various R-O fits are compared with reference J values. Comparisons show that the proposed R-O fit provides more accurate J values for all cases, compared to existing methods for the R-O fit. Advantages of the proposed R-O fit in practical applications are discussed, together with its accuracy.

The Relation between Pullout Load and Compressive Strength of Ultra-High-Strength Concrete (초고강도 콘크리트의 인발하중과 압축강도와의 관계)

  • Ko, Hune-Beom;Kim, Ki-Tae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • The pullout test, a nondestructive testing(NDT), for pre-installed inserts is perhaps the most widely used technique to estimate the in-situ compressive strength of concrete. It measures the force needed to pullout a standardized metal insert embedded into concrete members. The pullout test was certified by the American Society for Testing and Materials(ASTM) and Canadian Standards Association(CSA) as a reliable method for determining the strength of concrete in concrete structures under construction. To easily estimate the strength of ultra-high-strength concrete, a simplified pullout tester, primarily composed of a standard 12mm bolt with a groove on the shaft as a break-off bolt, an insert nut, and a hydraulic oil pump without a load cell, was proposed. Four wall and two slab specimens were tested for two levels of concrete strength, 80MPa and 100MPa, using a simplified pullout tester with a load cell to verify the advantages of the pullout test and simplified pullout test. The compressive strength of concrete, pullout load, and the rupture of the break-off bolt were measured 11 times, day 1 to 7, 14, 21, 28, and 90. The correlation of the pullout load and the compressive strength of each specimen show a higher degree of reliability. Therefore, a simplified pullout test can be used to evaluate the in-place strength of ultra-high-strength concrete in structures. The prediction equation for the groove diameter of the break-off bolt(y) with the concrete strength(x) was proposed as y=0.0184x+5.4. The results described in this research confirm the simplified pullout's utility and potential for low cost, simplicity, and convenience.

External Condensation Heat Transfer Coefficients of HFC32/HFC152a Mixtures on Enhanced Tubes (열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수)

  • Lee, Yohan;Kang, Donggyu;Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.315-321
    • /
    • 2014
  • In this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC152a at various compositions were measured on both 26 fpi low-fin and Turbo-C enhanced tubes, of 19.0 mm outside diameter. All data were taken at the vapor temperature of $39^{\circ}C$, with a wall subcooling of 3~8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids.

Eulerian-based Numerical Modeling for Impingement Prediction of Supercooled Large Droplets (과냉각대형액적 충돌예측을 위한 오일러리안 기반 수치 모델링)

  • Jung, Sung-Ki;Kim, Ji-Hong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.8
    • /
    • pp.647-654
    • /
    • 2012
  • Supercooled large droplet issues in aircraft icing have been continually reported due to the important safety considerations. In order to simulate the impingement behavior of large droplets, a two-dimensional and compressible Navier-Stokes code was developed to determine the flow field around the test model. Also, the Eulerian-based droplet impingement model including a semi-empirical approach for the droplet-wall interaction process and droplet break-up was developed. In particular, the droplet-wall interactions were considered as numerical boundary conditions for the droplet impingement simulation in the supercooled large droplet conditions. Finally, the present results were compared with the experimental test data and the LEWICE results. The droplet impingement area and maximum collection efficiency values between present results and wind tunnel data were in good agreements. Otherwise, the inclination of collection efficiency of the present result is over-predicted than the wind tunnel data around a lower surface of the NACA 23012 airfoil.

Arc Resistance and Light Reflectance of PTFE for Circuit Breaker (차단기용 PTFE의 내아크성과 광반사율)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Lee, Tae-Joo;Lee, Tae-Hui;Myung, In-Hae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.200-203
    • /
    • 2003
  • A study on the arc resistance and light reflectance of PTFE (polytetrafluoroethylene) nozzle for circuit breaker is presented. PTFE has been used widely as a material for circuit breaker nozzle. PTFE has excellent electrical resistivity, high melt viscosity, chemical inertness, heat resistance and low loss factor. PTFE melts at $327\;^{\circ}C$ but the viscosity is very high above the melting point. In the arcing environment in a circuit breaker, the fraction of the power is emitted out of the arc and reaches the nozzle wall by radiation, causing ablation at the surface and in the depth of the wall. Some fraction of the radiation power emitted out of the arc directly break up the chemical bonds at the surface while some fraction of the radiation power penetrates into the wall, heats up the material to evaporation temperature and causes damages deeper inside the volume of the nozzle. In this paper, some fillers that have endurance in the high temperature arc environment were added into PTFE. Adding some fillers into PTFE was expected to be efficient in improving the endurability against radiation. The light reflectance and arc resistance of PTFE composites were investigated.

  • PDF

NUMERICAL SIMULATION OF BOILING PHENOMENA USING A LEVEL-SET METHOD (Level-Set 방법을 이용한 비등현상 해석)

  • Son, G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.218-222
    • /
    • 2009
  • A level-set (LS) method is presented for computation of boiling phenomena which involve liquid-vapor interfaces that evolve, merge and break up in time, the flow and temperature fields influenced by the interfacial motion, and the microlayer that forms between the solid and the vapor phase near the wall. The LS formulation for tracking the phase interfaces is modified to include the effects of phase change on the liquid-vapor interface and contact angle on the liquid-vapor-solid interline. The LS method can calculate an interface curvature accurately by using a smooth distance function. Also, it is straightforward to implement for two-phase flows in complex geometries. The numerical method is applied for analysis of nucleate boiling on a horizontal surface and film boiling on a horizontal cylinder.

  • PDF

Case Report of a Simple Rib Fracture Caused by Coughing (기침으로 초래된 단순 늑골골절 1례)

  • Choi, Woo-Ik
    • Journal of Trauma and Injury
    • /
    • v.27 no.1
    • /
    • pp.9-12
    • /
    • 2014
  • Violent or severe persistent coughing is rarely associated with rib fracture. We report a rare case of a cough-induced rib fracture in a patient without any traumatic history or any other underlying disease. A 32-year-old female presented to the emergency department complaining of having had right-sided pleuritic chest pain for 5 days. She had a background of an 8-week coughing illness. A posteroanterior view of the chest radiograph showed no definite fractured line. Chest computed tomography revealed a subtle break cortical line of the 7th rib in the right-sided chest wall. Early identification of a cough-induced fracture of the rib by using computed tomography may avoid unnecessary further work-ups including laboratory examination and may lead to appropriate discharge instructions including rest and reassurance. The clinical presentations and radiologic findings of rib fractures caused by coughing are presented along with a review of the literature.

Effect of Restraint of Pressure Induced Bending on Crack Opening for Circumferential Crack (원주방향 균열의 균열열림에 미치는 압력유기굽힘의 구속 효과)

  • Kim, Jin-Weon;Park, Chi-Yong
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.849-855
    • /
    • 2000
  • This study evaluated the effect of restraint of pressure induced bending(PIB) on crack mouth opening displacement(CMOD) for circumferential through-wall crack in pipe by using both elastic and elastic-plastic finite element analyses. The analyses results showed the restraint of PIB was decreased crack opening for a given crack length and tensile stress, and the effect was considerable for large crack and short restraint length. Also, the restraint effect on CMOD was independent on the variation in pipe diameter and decreased with increasing pipe thickness, and it depended on not total restraint length but short restraint length for non-symmetrically restrained. Additionally, the effect of restraint of PIB was more significant in the elastic-plastic analysis results compared with in the elastic analysis results.

  • PDF

A Study on the Flame Propagating Speed Measurement-For the Laminar Flame- (火焰傳播速度測定에 關한 硏究 -層流火焰에 關하여-)

  • 조경국;정인석;허원욱
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.1 no.1
    • /
    • pp.28-41
    • /
    • 1979
  • Propane-Air premixed combustible gas was ignited by the conventional current break system inside the open combustion chamber under the atmospheric pressure and the room temperature to measure the flame propagating speed and the burning speed, also to elucidate the history of the propagating flame behavior and wall effects to flame shape by using Ion Gap Method and High Speed Schlieren Photography. The results obtained show that the maximum flame propagating speed and maximum burning speed are approximately 292 cm/sec and 36 cm/sec at the mixture ratio 4.6%, respectively. The cellular flame structures can be observable in the rich mixture region, moreover, the cellular structures become finer, with increasing the mixture strength.

  • PDF