• Title/Summary/Keyword: Wall break

Search Result 116, Processing Time 0.027 seconds

New Engineering J and COD Estimation Methods for Axial Through-Wall Cracked Pipes (축방향 관통균열 배관의 새로운 탄소성 J-적분 및 COD 계산식)

  • Huh, Nam-Su;Park, Young-Jae;Kim, Yun-Jae;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.239-246
    • /
    • 2003
  • This paper proposes engineering estimation equations of elastic-plastic J and COD fur axial through-wall cracked pipes under internal pressure. Based on detailed 3-D FE results based on deformation plasticity, the plastic influence functions for fully plastic J and COD solutions are tabulated as a function of the mean radius-to-thickness ratio, the normalized crack length. and the strain hardening. Based on these results, the GE/EPRI-type J and COD estimation equations are proposed and validated against the 3-D FE results based on deformation plasticity. For more general application to general stress-strain laws or to complex loading, the developed GE/EPRI-type solutions are re-formulated based on the reference stress concept. Such a reformulation provides simpler equations for J and COD, which are then further extended to combined internal pressure and bending. The proposed reference stress based J and COD estimation equations are compared with elastic-plastic 3-D FE results using actual stress-strain data for Type 316 stainless steels. The FE results for both internal pressure cases and combined internal pressure and bending cases compare very well with the proposed J and COD estimations.

Condensation Heat Transfer Coefficients of Binary Refrigerant Mixtures on Enhanced Tubes (열전달 촉진관에서 2원 혼합냉매의 외부 응축열전달계수)

  • 김경기;서강태;채순남;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.161-167
    • /
    • 2002
  • In this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC134a and HF0134a/HCF0123 at various compositions were measured on both low fin and Turbo-C enhanced tubes of 19.0 mm outside diameter All data were taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling of 3- 8 K. Test results showed that HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by the mass fraction weighting of the pure compo- nents'HTCs. Also the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased as the wall subcooling increased, which was due to the sudden break up of the vapor diffusion film with an increase in wall subcooling. Finally, heat transfer enhancement ratios for mixtures were found to be much lower than those of pure fluids.

Study on Plugging Criteria for Thru-wall Axial Crack in Roll Transition Zone of Steam Generator Tube (증기발생기 전열관 확관천이부위 축방향 관통균열의 관막음 기준에 관한 연구)

  • Park, Myeong-Gyu;Kim, Yeong-Jong;Jeon, Jang-Hwan;Kim, Jong-Min;Park, Jun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2894-2900
    • /
    • 1996
  • The stream generator tubes represent an integral part of a major barrier against the fission product release to the environment. So, the rupture of these tubes could permit flow of reactor coolant into the secondary system and injure the safety of reactor coolant system. Therefore, if the crack was detected during In-Service Inspection of tubes the cracked tube should be evaluated by the pulgging criteria and plugged or not. In this study, the fracture mechanics evaluation is carried out on the thru-wall axial crack due to Primary Water Stress Corrosion Cracking in the roll transition aone of steam generator tube to help the assurence the integrity of tubes and estabilish the plugging criteria. Due to the Inconel which is used as tube material is more ductile than others, the plastic instability repture theory was used to calculate the critical and allowable crack length. Based on Leak Before Break concept the leak rate for the critical crack length and the allowable leak rate are compared and the safety of tubes was given.

Study on Effect of Anchor Bolt by Thermal Expansion of Sulfur Storage Tank under High Temperature (고온을 받는 유황저장탱크의 열팽창에 의한 앵커볼트 영향에 관한 연구)

  • Jung, Wook-Hwan;Kim, Jeong-Soo;Kim, Tae-Min;Kim, Moon-Kyum
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.483-490
    • /
    • 2016
  • In plant industry, sulfur storage tank is made of steel and annular plate is connected with concrete foundation of ring wall type by anchor bolt. Due to keep sulfur at high temperature in tank by coil, sulfur storage tank is expanded larger than another tank stores fluid at room temperature. Generally, structural design of tank foundation is performed analysis with loading of temperature gradient between inner and outer surface, this method can't consider the phenomenon that load is intensively transferred to concrete foundation at anchor bolt. This means that temperature load is underestimated and causes crack of concrete near anchor bolt. In this study, evaluation formula considering temperature load transfer mechanism through anchor bolt is proposed and load acting on concrete foundation is rationally decided. For this purpose, it is analyzed variation of thermal load per various anchor bolt number using finite element model including tank annular plate and anchor bolt. Solution is proposed as specified term combining result of analysis and theoretical solution for evaluating load transferred by anchor bolt. For confirmation of validation of proposed formula, it is applied in design of sulfur storage tank at plant site, it shows that the formula can be practically applied.

In vitro propagation of Bambusa nutans Wall. ex Munro through axillary shoot proliferation

  • Negi, Divya;Saxena, Sanjay
    • Plant Biotechnology Reports
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • This communication describes for the first time an efficient and reproducible protocol for large-scale multiplication of Bambusa nutans. Nodal segments collected from field-grown clumps and cultured on Murashige and Skoog (MS) medium supplemented with $4.4{\mu}M$ benzylaminopurine (BA) and $2.32{\mu}M$ kinetin (Kin) gelled with 0.2% gelrite yielded 80% aseptic cultures with 100% bud-break. The in vitro-formed shoots obtained after bud-break were successfully multiplied in MS liquid medium supplemented with $13.2{\mu}M$ BA, $2.32{\mu}M$ Kin, and $0.98{\mu}M$ indole-3-butyric acid (IBA). Sub-culturing of shoots every 3 weeks on fresh multiplication medium yielded a consistent proliferation rate of 3.5-fold. Shoot clusters containing three to five shoots were successfully rooted with 100% success on half-strength MS liquid medium supplemented with $9.8{\mu}M$ IBA, $2.85{\mu}M$ indole-3-acetic acid (IAA), $2.68{\mu}M$ naphthaleneacetic acid (NAA), and 3% sucrose. Plantlets grown in vitro were acclimatized and subsequently transferred to the field. Inter-simple sequence repeat analysis has confirmed the genetic uniformity of the tissue-cultured plants up to 27 passages.

Effect of Beating and Pressing on Fracture Toughness of Paper (고해와 압착처리가 종이의 파괴인성에 미치는 영향)

  • 윤혜정;신동소
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.4
    • /
    • pp.1-9
    • /
    • 2000
  • As the speed of the paper machine and printing press increases, the dependency of the production efficiency upon the frequency of web break increases. It is believed that flaw or crack that presents in paper is one of the most important for web break. Runnability of papers on the paper machine could be evaluated by measuring fracture toughness. In this paper the effect kof beating and pressing on the runnability was investigated using handsheets made from softwood bleached kraft pulp beaten to different freeness. Pressing pressure was also varied to obtain different levels of sheet consolidation. Density, tensile strength, and J-integral of the handsheets were evaluated. For measuring J-integral either a single specimen method or RPM method was employed. Results showed that the density and tensile strength were improved as beating and pressing increased because of increased interfiber bonding. J-integral increased with beating until the CSF reached 400mL. No significant difference in J-integral, however, was observed afterward with the increase of beating. And it appeared to be due to acceleration of the stress concentration around the crack that exists on the fiber wall of the sheet when cracks exists.

  • PDF

Effect of Wind Break on the Early Growth of Pinus thunbergii at Saemangum Sea-wall (새만금 방조제에서 곰솔의 초기 생장에 미치는 방풍 시설 설치 효과)

  • Kim, Jeong-Hwan;Lim, Joo-Hoon;Seo, Kyung-Won;Jeong, Yong Ho;Um, Tae-Won
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.15 no.4
    • /
    • pp.210-218
    • /
    • 2013
  • The sea breeze shows different characteristics compared to land breeze, such as high wind speed and more rapider shift period. One of the major factors affecting plant early growth is wind speed. In the early growth stage, tree growth-rates rise with decreasing wind speed. Thus, the study was performed to identify wind break effects on wind characteristics and tree growth. The wind break used in this study was about 130 meters length and 3 meters height, made up with poly-ethylene (with 40% openness). We installed one vane and fifteen anemographs at three different heights (1, 2 and 3 meters) on the inner and outer wind break areas. The wind characteristic and plant growth data were collected from Jun. 2011 to Oct. over 2012. The wind rose of the Saemangum seawall area presented the north (21.5%) and it was followed by north-west (18.1%), east (14.9%) and north-east (13.7%) and the remainder with other directions. Wind speeds at height were different. The tree height was 159.6 cm at inside and 129.6 cm at outside. The diameter at root-collar was 36.9 mm at inside and 32.6 mm at outside from wind break.

Application of Prefabricated Retaining Walls with Steel Lagging (강재 요소를 적용한 조립식 흙막이 벽체에 관한 연구)

  • Hong, Jong woo;Choi, Jae Soon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.1277-1285
    • /
    • 2015
  • It has been known that the conventional retaining wall system with timber lagging and H pile has several problems such as the irregular gap between H-piles, cutting or adding to standard timber, back fill over first step excavation, and especially break-down accident at the disjoint of wall system. In the practical excavation, these problems may lead to worker's accident and the inefficiency of construction economy. To solve the above problems, a new method using prefabricated retaining wall was proposed and verified. The characteristics of the new method is to replace timber wall as free-sliding steel-lagging and connector. To check its verification and application, laboratory tests such as bending strength, tensile strength, and fatigue strength were carried out. Also, a pilot test in the field and numerical simulations under various ground conditions were performed. From the researches, it is found that the prefabricated retaining wall plate can be superior to the conventional timber lagging plate in the strength. It is also found that the proposed methods can be effective in the reuse of retaining wall plate and safe in the disjoint of wall system. Finally, it is desired that the proposed method will be effective in the reduction of the imported timbers and helpful in the safety of retaining wall construction.

On Relevant Ramberg-Osgood Fit to Engineering Non-Linear Fracture Mechanics Analysis (정확한 비선형 파괴역학 해석을 위한 새로운 Ramberg-Osgood 상수 결정법)

  • Kim, Yun-Jae;Huh, Nam-Su;Kim, Young-Jin;Choi, Young-Hwan;Yang, Jun-Seok
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.170-177
    • /
    • 2003
  • This paper proposes a robust method for the Ramberg-Osgood (R-O) fit to accurately estimate elastic-plastic J from engineering fracture mechanics analysis based on deformation plasticity. The proposal is based on engineering stress-strain data to determine the R-O parameters, instead of true stress-strain data. Moreover, for practical applications, the method is given not only for the case when full stress-strain data are available but also for the case when only yield and tensile strengths are available. Reliability of the proposed method for the R-O fit is validated against detailed 3-D Finite Element (FE) analyses for circumferential through-wall cracked pipes under global bending using five different materials, three stainless steels and two ferritic steels. Taking the FE J results based on incremental plasticity using actual stress-strain data as reference, the FE J results based on deformation plasticity using various R-O fits are compared with reference J values. Comparisons show that the proposed R-O fit provides more accurate J values for all cases, compared to existing methods for the R-O fit. Advantages of the proposed R-O fit in practical applications are discussed, together with its accuracy.

  • PDF

A Study on the Commercial Streetscape Design Guideline of the Historic and Cultural Environmental Districts in Ancient Capital Gyeongju (고도(古都) 경주의 역사문화환경지구 내 상업가로경관 디자인가이드라인에 관한 연구)

  • Hyun, Taek-Soo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.16 no.1
    • /
    • pp.87-94
    • /
    • 2014
  • The objective of this study is to provide a townscape design guideline that harmonized with a historic landscape via condition investigation and landscape analysis of the cultural /commercial environment district where an improvement is a necessity. The followings are the conclusions: 1.To enhance the identity of Gyeongju, should pursue diversity in unity by making the image of architectural landscape a similar peculiarity. 2.The central commercial district where the tradition is valued and contemporary figures meet the tradition needs a landscape formation by CONTEXT. 3.Since a characteristic of the target area is a regional commercial center, to reduce its congestion, reforming the area to simple environment is required. 4.Induce buildings located on the streets with cultural properties to have Korean traditional tiled roof in order to fit in with their surroundings. 5.Make it a rule to partition a wall into tripartition, the wall surface exposed should be the same finishing materials. 6.Consider the visual aspect of pedestrians and a building's width, the recommendable height of the facade should be 3~3.6m. 7.For the design archetype of cornice, four traditional types based on Korean traditional eaves are suggested. 8.The design of signboards should break existing square-shapes, and seek a design to take advantage of icons that historicity and traditionalist of the city are expressed.