기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구 (The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment)

  • 김서훈;김종훈;류승환;정학근;송규동
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

The method of in-situ ASTR method diagnosing wall U-value in existing deteriorated houses - Analysis of influence of internal surface total heat transfer rate -

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jeong, Hakgeun;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • 제17권4호
    • /
    • pp.41-48
    • /
    • 2017
  • Purpose : Currently, 25% of the domestic energy consumption structure is used as building energy, and more than 18% of this energy is consumed in the residential. Accordingly, various efforts and policies that can save energy of the building is being performed. The various researchers are conducting research to diagnose the thermal performance of existing buildings. This study is to apply in the field of precision thermal insulation performance diagnostic method for thermal performance analysis of existing detached house in Seoul, Gangreung, Gyeongju, Pohang. And this paper is analyzed quantitatively measure the existing detached house energy performance. Method: Research methodology analyzed the thermal performance over the Heat Flow Meter method by applying the measurement process and method by applying the criteria of ISO 9869-1 & ASTR method. In this study, the surface heat transfer coefficient was calibrated by applying indoor surface heat transfer resistance with reference to ISO 6946 standard. The measurement error rate between the HFM diagnosis method and the ASTR diagnosis method was reduced and the measurement reliability was obtained through measurement method error verification. Result : As a result of the study, the thermal performance vulnerable parts of the building were quantitatively analyzed, and presented for methods which can be improved capable of efficient energy use buildings.

관상동맥 우회술 후 심근경색의 표지자로서 Creatine Kinase MB 농도와 Cardiac Troponon I의 임상적 의의 (Clinical Significance of Creatine Kinase MB mass and Cardiac Troponin I as a Marker of Perioperative Myocardial Infarction After Coronary Artery Bypass Grafting)

  • 이재진;김응중;이원용;신윤철;지현근
    • Journal of Chest Surgery
    • /
    • 제35권1호
    • /
    • pp.27-35
    • /
    • 2002
  • 배경: 술후 심근경색(perioperative myocardial infarction;PMI)은 관상동맥 우회술 후 중요한 합병증 중 하나이다. PMI의 진단 방법 중 CK-MB 활성도(CK-MB activity) 측정보다 민감하고, 간단한 측정 방법을 가진 CK-MB 농도(CK-MB mass)의 측정으로 점차 대체되고 있다. 또한, cardiac troponin I(cTnl)는 심근경색의 표지자로 민감도와 특이도가 가장 높은 것으로 소개되고 있다. 본 연구는 관상동맥 우회술 후 심근경색의 표지자로서 CK-MB농도와 cTnl의 임상적 의의성에 대한 평가를 보고하고자 한다. 대상 및 방법: 2000년 4월부터 2001년 4월까지 강동성심병원에서 관상동맥 우회술을 받은 32명의 환자를 대상으로 하였다. 술후 CK-MB 활성도, CK-MB농도, cTnl, 심전도, 심초음파, 임상적 자료를 전향적으로 기록하였다. 술후 심근경색의 진단은 심전도에서 새로운 Q파 출현, CK-MB 활성도가 72시간안에 200 lU/L 이상, 심초음파에서 심근벽의 새로운 심근벽 운동이상 등의 3가지 중 2가지 이상인 경우로 정의하였다 결과: 관상동맥 우회술 후 3례에서 진단 기준에 부합된 경우였다. 시간 경과에 따라, 술후 12시간의 CK-MB활성도와 술후 24시간의 CK-MB농도(R=0.946), 술후 48시간의 cTnl(R=0.933)는 매우 상관성이 있었다(p=0.000). PM의 진단기준치를 찾기 위해 ROC(receiver operating characteristics) 곡선을 이용하였으며, PMI의 환자중 술후 24시간에서 CK-MB 농도가 30.05 ug/L보다 높은 측정값에서 PMI를 발견할 수 있었고, 이 때의 ROC 곡선의 하단 단면적은 1이었으며, 민감도 100%, 특이도 100%, 양성 예측도 100%, 음성 예측도 100% 이었다. cTnI의 경우 술후 48시간에서 17.15ug/L보다 높은 측정값에서 PMI를 발견할 수 있었고, 이 때의 ROC 곡선의 하단 단면적은 0.98이었으며, 민감도 100%, 특이도 96.6%, 양성 예측도 75%, 음성 예측도 100% 이었다. 결론: 관상동맥 우회술 후 심근경색의 진단적 표지자로서 CK-MB농도와 cTnl의 측정은 간단하고 정확한 방법으로 판단되며, 진단기준치를 제시함으로서 술후 심근경색의 조기 발견을 가능하게 할 수 있을 것이라 생각된다. 그러나 본 연구에서는 대상환자 수가 적었고, 적은 수의 환자에서 심근경색이 발생하여 통계적인 제한이 있을 수 있어 향후 더 많은 대상의 수가 필요할 것으로 사료된다.