• 제목/요약/키워드: Wall Strengthening

검색결과 102건 처리시간 0.027초

현장타설 끼움 벽으로 보강된 비내진 상세를 갖는 철근콘크리트 골조의 내진거동 (Seismic Behavior of Non Ductile Reinforced Concrete Frame Retrofitted With Cast-In Place Infilled Shear Wall)

  • 이혜연;김선우;한병찬;윤현도;최창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.453-456
    • /
    • 2004
  • RC frames built prior to the advent of the philosophy of ductile concrete is one type of existing construction susceptible to damage. Strengthening and stiffening of such frames has been accomplished by infilled frames with cast-in-place, reinforced concrete walls. Placement of CIP shear walls within strategic bays of a structure appears to be a logical and economical method to strengthen a reinforced concrete frame and to stiffen a building in order to reduce architectural and mechanical damage. This study investigates the seismic performance of cast-in place infilled shear wall within existing frames. The object of this study is to clarify the seismic capacity and characteristics in the hysteretic behavior of bare frame, CIP infilled shear wall and CIP infilled wall reinforced diagonal bars.

  • PDF

Effects of Material Nonlinearity on Seismic Responses of Multistoried Buildings with Shear Walls and Bracing Systems

  • Islam, Md. Rajibul;Chakraborty, Sudipta;Kim, Dookie
    • Architectural research
    • /
    • 제24권3호
    • /
    • pp.75-84
    • /
    • 2022
  • Scads of earthquake-resistant systems are being invented around the globe to ensure structural resistance against the lateral forces induced by earthquake loadings considering structural safety, efficiency, and economic aspects. Shear wall and Bracing systems are proved to be two of the most viable solutions for seismic strengthening of structures. In the present study, three numerical models of a G+10 storied building are developed in commercial building analysis software considering shear wall and bracing systems for earthquake resistance. Material nonlinearity is introduced by using plastic hinges. Analyses are performed utilizing two dynamic methods: Response Spectrum analysis and nonlinear Time-history analysis using Kobe and Loma Prieta earthquake data and results are compared to observe the nonlinear behavior of structures. The outcomes exposed that a significant increase in the seismic responses occurs due to the nonlinearity in the building systems. It was also found that building with shear wall exhibits maximum resistance and minimum nonlinearity when subjected to dynamic loadings.

RC자켓팅으로 보강된 기존 벽체의 면외방향 내진성능 실험평가 (Experimental Investigation of Out-of-Plane Seismic Resistance of Existing Walls Strengthened with RC Jacketing)

  • 엄태성;허무원;이상현;이범식;천영수
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.239-248
    • /
    • 2019
  • In this study, the out-of-plane seismic resistance of lightly-reinforced existing walls strengthened with thick RC jacket was investigated. The thick RC jacket with a thickness of 500 mm was placed at one side of the thin existing wall with a thickness of 150 mm. At the interface between the wall and RC jacket, a tee-shaped steel section with a number of anchor bolts and dowel bars was used as the shear connector. To investigate the connection performance and strengthening effects, the cyclic loading tests of four jacketed wall specimens were performed. The tests showed that the flexural strength of the jacketed walls under out-of-plane loading was significantly increased. During the initial behavior, the tee shear connector transferred forces successfully at the interface without slip. However, as the cracking, spalling, and crushing of the concrete increased in the exiting walls, the connection performance at the interface was significantly degraded and, consequently, the strength of the jacketed walls was significantly decreased. The flexural strength of the jacketed walls with tee shear connector was estimated considering the full and partial composite actions of the tee shear connector.

FRP 시트로 보강된 철근콘크리트 벽체의 방호성능 평가 (Evaluation on Blast Resistance Performance of Reinforced Concrete Wall Strengthened by FRP Sheet)

  • 이건호;김재민;김재현;이상훈;김강수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권5호
    • /
    • pp.151-160
    • /
    • 2022
  • 최근 폭발사고의 빈도수가 증가함에 따라 주요 구조부재의 손상을 저감시킬 수 있는 방호 구조물 설계에 대한 관심이 높아지고 있다. 그러나, 방호 구조물의 방호성능에 대한 국내 연구는 아직 미진한 실정이며, 아직 설계 가이드라인도 충분히 갖추어지지 못한 실정이다. 따라서, 본 연구에서는 FRP 시트 보강유무를 변수로 하여 RC 방호벽에 대한 해석적 연구를 수행하였다. 해석은 LS-DYNA 프로그램을 활용하여 수행되었으며, 해석을 통해 RC 방호벽과 FRP 시트로 보강된 RC 방호벽의 변위-시간이력곡선, 압력-충격량 도표, 취약도 곡선을 도출하였다. FRP 시트 보강방법은 RC 방호벽의 방호성능을 향상시키는데 매우 효율적인 것으로 나타났다. 또한, 폭발하중의 크기가 클수록 RC 방호벽에 대한 FRP 시트의 보강효과는 높아지는 것으로 나타났다.

Axial behavior of RC columns strengthened with SCC filled square steel tubes

  • Lu, Yi-Yan;Liang, Hong-Jun;Li, Shan;Li, Na
    • Steel and Composite Structures
    • /
    • 제18권3호
    • /
    • pp.623-639
    • /
    • 2015
  • Self-compacting Concrete (SCC) Filled Square steel Tubes (SCFST) was used to strengthen square RC columns. To establish the efficiency of this strengthening method, 17 columns were tested under axial compression loading including 3 RC columns without any strengthening (WRC), 1 RC column strengthened with concrete jacket (CRC), 13 RC columns strengthened with self-compacting concrete filled square steel tubes (SRC). The experimental results showed that the use of SCFST is interesting since the ductility and the bearing capacity of the RC columns are greatly improved. The improvement ratio is significantly affected by the nominal wall thickness of steel tubes (t), the strength grade of strengthening concrete (C), and the length-to-width ratio (L / B) of the specimens. In order to quantitatively analyze the effect of these test parameters on axial loading behavior of the SRC columns, three performance indices, enhancement ratio (ER), ductility index (DI), and confinement ratio (CR), were used. The strength of the SRC columns obtained from the experiments was then employed to verify the proposed mode referring to the relevant codes. It was found that codes DBJ13-51 could relatively predict the strength of the SRC columns accurately, and codes AIJ and BS5400 were relatively conservative.

Experimental study on shear, tensile, and compression behaviors of composite insulated concrete sandwich wall

  • Zhang, Xiaomeng;Zhang, Xueyong;Liu, Wenting;Li, Zheng;Zhang, Xiaowei;Zhou, Yilun
    • Advances in concrete construction
    • /
    • 제11권1호
    • /
    • pp.33-43
    • /
    • 2021
  • A new type of composite insulated concrete sandwich wall (ICS-wall), which is composed of a triangle truss steel wire network, an insulating layer, and internal and external concrete layers, is proposed. To study the mechanical properties of this new ICS-wall, tensile, compression, and shearing tests were performed on 22 specimens and tensile strength and corrosion resistance tests on 6 triangle truss joints. The variables in these tests mainly include the insulating plate material, the thickness of the insulating plate, the vertical distance of the triangle truss framework, the triangle truss layout, and the connecting mode between the triangle truss and wall and the material of the triangle truss. Moreover, the failure mode, mechanical properties, and bearing capacity of the wall under tensile, shearing, and compression conditions were analyzed. Research results demonstrate that the concrete and insulating layer of the ICS-wall are pulling out, which is the main failure mode under tensile conditions. The ICS-wall, which uses a graphite polystyrene plate as the insulating layer, shows better tensile properties than the wall with an ordinary polystyrene plate. The tensile strength and bearing capacity of the wall can be improved effectively by strengthening the triangle truss connection and shortening the vertical distances of the triangle truss. The compression capacity of the wall is mainly determined by the compression capacity of concrete, and the bonding strength between the wall and the insulating plate is the main influencing factor of the shearing capacity of the wall. According to the tensile strength and corrosion resistance tests of Austenitic stainless steel, the bearing capacity of the triangle truss does not decrease after corrosion, indicating good corrosion resistance.

골조 외부에 부착한 강재댐퍼의 성능 평가 (Capacity Evaluation of Steel Damper Attached to Outside of Frame)

  • 이현호
    • 한국건설순환자원학회논문집
    • /
    • 제5권4호
    • /
    • pp.382-388
    • /
    • 2017
  • 본 연구에서는 공공건물에 보강이 가능하도록 건물 외부에 록킹 월을 설치하고 이를 본 구조에 강재댐퍼로 연결하는 외부 보강 내진공법에 대한 기초 연구를 시행하였다. 2개의 실험체를 제작하였으며, 댐퍼 비보강 실험체는 기존 결과를 활용하였다. 포락선, 강도, 강성저하 및 에너지 소산능력을 평가한 결과, 플레이트 댐퍼를 외부 보강한 RW_P 실험체의 강도 증진이 우수한 것으로 평가되었다. 또한 S형 댐퍼를 외부 부착한 RW_S 실험체는 최대하중 이후에 완만한 포락곡선을 보여 댐퍼가 하중을 적절히 소산하는 것을 확인할 수 있었다.

Structural efficiency of various strengthening schemes for cold-formed steel beams: Effect of global imperfections

  • Dar, M. Adil;Subramanian, N.;Dar, A.R.;Majid, Muheeb;Haseeb, Mohd;Tahoor, Mugees
    • Steel and Composite Structures
    • /
    • 제30권4호
    • /
    • pp.393-403
    • /
    • 2019
  • Cold-formed steel (CFS) has a great potential to meet the global challenge of fast-track and durable construction. CFS members undergo large buckling instabilities due to their small wall thickness. CFS beams with corrugated webs have shown great resistance towards web buckling under flexure, when compared to the conventional I-sections. However, the magnitude of global imperfections significantly affects the performance of CFS members. This paper presents the first attempt made to experimentally study the effect of global imperfections on the structural efficiency of various strengthening schemes implemented in CFS beams with corrugated webs. Different strengthening schemes were adopted for two types of beams, one with large global imperfections and the other with small imperfections. Strength and stiffness characteristics of the beams were used to evaluate the structural efficiency of the various strengthening schemes adopted. Six tests were performed with simply supported end conditions, under four-point loading conditions. The load vs. mid-span displacement response, failure loads and modes of failure of the test specimens were investigated. The test results would compensate the lack of experimental data in this area of research and would help in developing numerical models for extensive studies for the development of necessary guidelines on the same. Strengthening schemes assisted in enhancing the member performance significantly, both in terms of strength and stiffness. Hence, providing an economic and time saving solution to such practical structural engineering problems.

국내 기존 학교건축물의 내진보강 후 비선형 거동특성 (Nonlinear Behavior of Seismic-Strengthened Domestic School Building)

  • 류승현;윤현도;김선우;이강석;김용철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.243-253
    • /
    • 2011
  • 본 논문은 내진설계규정이 적용되지 않은 국내 철근콘크리트 학교 건물에 관한 해석적 연구이다. 일본의 내진진단과 비선형 정적 및 동적 해석을 통하여 대상 건축물의 내진 성능을 평가하였다. 일본의 내진진단 방법에 기초하여 철근 콘크리트 학교 건물의 부족한 내진 성능을 파악하였다. 또한, 횡하중을 받는 학교 건물의 내진거동이 해석적으로 평가되었다. 건축물의 내진 보강을 위하여 1,300kN의 내력을 받는 전단벽과 K형 가새골조가 사용되었다. 비선형 정적해석 결과, 보강에 의한 전단내력은 보강 전에 비하여 30%이상의 향상을 보이는 것으로 나타났으며, 전단벽 보강 시 최대 하중 이후에서 가새골조 보강에 비해 큰 강성저하를 나타내었다. 또한, 성능점 산정 결과에서 가새골조로 보강된 건축물이 전단벽으로 보강된 건축물에 비해 30% 이상의 변형능력을 보였다. 한편 비선형 동적해석의 시간이력해석 결과에서는 가새골조와 전단벽에 의해 보강된 건축물의 최대 변위가 보강량이 증가할수록 감소하는 경향을 나타내었다. 본 연구는 이 외에도 지진 지역에서의 건축물의 내진성능 향상을 위해 다양한 지반 조건과 지진파를 고려되어야 한다고 판단된다.

자연친화적인 보강토 옹벽의 철판망 gabion 보강재 타당성 분석 (A Feasibility Analysis on Steel Net Gabion Reinforcement of Reinforced Earth-retaining Wall)

  • 정대석
    • 한국환경과학회지
    • /
    • 제17권2호
    • /
    • pp.135-140
    • /
    • 2008
  • Steel net gabion is eco-friendly retaining wall structure showing favorable ability to overcome construction and environmental restriction and also to resist corrosion, chemical attack and degradation. This paper is dealt with the applicability of gabion metal net as a substitution of existing strengthening material. Pull out test was carried out to verify the applicability of gabion metal net. According to results, the increase of surcharge loading and horizontal load resulted in a yield of metal net. The stress at the time of yield was in the range of elasticity. Accordingly, gabion metal net can be substituted for existing geogrid and there is a need for experiment and analysis of arrangement direction and durability of gabion steel net.