• 제목/요약/키워드: Wall Protection

검색결과 283건 처리시간 0.025초

Physical protection system vulnerability assessment of a small nuclear research reactor due to TNT-shaped charge impact on its reinforced concrete wall

  • Moo, Jee Hoon;Chirayath, Sunil S.;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2135-2146
    • /
    • 2022
  • A nuclear energy facility is one of the most critical facilities to be safely protected during and after operation because the physical destruction of its barriers by an external attack could release radioactivity into the environment and can cause harmful effects. The barrier walls of nuclear energy facilities should be sufficiently robust to protect essential facilities from external attack or sabotage. Physical protection system (PPS) vulnerability assessment of a typical small nuclear research reactor was carried out by simulating an external attack with a tri-nitro toluene (TNT) shaped charge and results are presented. The reinforced concrete (RC) barrier wall of the research reactor located at a distance of 50 m from a TNT-shaped charge was the target of external attack. For the purpose of the impact assessment of the RC barrier wall, a finite element method (FEM) is utilized to simulate the destruction condition. The study results showed that a hole-size of diameter 342 mm at the front side and 364 mm at the back side was created on the RC barrier wall as a result of a 143.35 kg TNT-shaped charge. This aperture would be large enough to let at least one person can pass through at a time. For the purpose of the PPS vulnerability assessment, an Estimate of Adversary Sequence Interruption (EASI) model was used, which enabled the determination of most vulnerable path to the target with a probability of interruption equal to 0.43. The study showed that the RC barrier wall is vulnerable to a TNT-shaped charge impact, which could in turn reduce the effectiveness of the PPS.

Electrochemical Determination of Artemisinin Using a Multi-wall Carbon Nanotube Film-modified Electrode

  • Yang, Xiaofeng;Gan, Tian;Zheng, Xiaojiang;Zhu, Dazhai;Wu, Kangbing
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권7호
    • /
    • pp.1386-1390
    • /
    • 2008
  • Artemisinin, the effective ingredient of Chinese herb Artemisia annua L (Qinghao in Chinese), has been proved to be effective to antimalarial. Herein, a reliable, sensitive and convenient electrochemical method was developed for the determination of artemisinin utilizing the excellent properties of multi-wall carbon nanotube (MWNT). The electrochemical behavior of artemisinin was investigated. It is found that the reduction peak current of artemisinin remarkably increases and the peak potential shifts positively by 240 mV at the MWNT film-modified electrode. These phenomena indicate that the MWNT film exhibits efficient catalytic activity to the electrochemical reduction of artemisinin. The effects of pH value, amount of MWNT, scan rate and accumulation time were examined. The limit of detection (S/N = 3) is as low as 10 $\mu$ g $L^{-1}$. Finally, this newly developed method was used to determine the content of artemisinin in Artemisia annua L.

The Mitogen-Activated Protein Kinase Signal Transduction Pathways in Alternaria Species

  • Xu, Houjuan;Xu, Xiaoxue;Wang, Yu-Jun;Bajpai, Vivek K.;Huang, Lisha;Chen, Yongfang;Baek, Kwang-Hyun
    • The Plant Pathology Journal
    • /
    • 제28권3호
    • /
    • pp.227-238
    • /
    • 2012
  • Mitogen-activated protein kinase (MAPK) cascades are conserved signaling modules in the eukaryotic cells. They are involved in many major cell processes in fungi such as stress responses, vegetative growth, pathogenicity, secondary metabolism and cell wall integrity. In this review, we summarized the advances of research on the MAPK signaling pathways in Alternaria species. As major phytopathogenic fungi, Alternaria species reduce crop production. In contrast to the five MAPK pathways known in yeast, only three MAPK pathways as Fus3/Kss1-type, Hog1-type, and Slt2-type have been characterized in Alternaria. The Fus3/Kss1-type MAPK pathway participates in regulation of vegetative growth, conidiation, production of some cell-wall-degrading enzymes and pathogenicity. The Hog1-type pathway is involved in osmotic and oxidative stress, fungicides susceptibility and pathogenicity. The Slt2-type MAP kinases play an important role on maintaining cell wall integrity, pathogenicity and conidiation. Although recent advances on the MAPK pathways in Alternaria spp. reveal many important features on the pathogenicity, there are many unsolved problems regarding to the unknown MAP kinase cascade components and network among other major signal transduction. Considering the economic loss induced by Alternaria spp., more researches on the MAPK pathways will need to control the Alternaria diseases.

FWDB 정면충돌시험에 대한 연구 (Study on FWDB Frontal Vehicle Crash Test)

  • 김요셉;범현균
    • 한국자동차공학회논문집
    • /
    • 제18권6호
    • /
    • pp.31-37
    • /
    • 2010
  • In proportion to increasing interest in vehicle safety, many country have regulated vehicle safety and performed NCAP(New Car Assessment Program). However vehicles which had good results in these compliance and NCAP frontal crash test have caused problems such as the fork effect and over-riding in real car-to-car accidents. To complement these issues, new frontal crash test modes using new barrier like FWDB and PDB have been developed by EEVC WG15. In this paper, FWDB frontal crash test was performed and the result was compared with the full frontal crash test using the rigid wall in order to comprehend the characteristic of FWDB. The results of FWDB test were compared with one of USNCAP and KNCAP. Using USNCAP data, vehicle performance like deformation and wall force were studied. A comparative study of dummy injuries was made by using KNCAP result. The results showed that vehicle performance of FWDB test like displacement and effective acceleration was similar in spite of absorbing energy of FWDB due to the greater vehicle deformation of rigid wall test. In FWDB test, driver dummy head bottomed out but most of injuries were superior to the injury of rigid wall test.

농가주택 법면 보호공을 위한 환경친화블럭의 적용성 평가 (Application of Environmentally friendly block for the slope stability and protection of Rural Housing)

  • 신방웅;오세욱;권영철;조천희;한현구
    • 한국농촌건축학회논문집
    • /
    • 제2권1호
    • /
    • pp.101-112
    • /
    • 2000
  • Green environment is most important factor to human being taking a side view of psychological aspect. But, as the civilization progresses rapidly, the green environment decreases. At present, various environmentally friendly methods are developed to prevent the ill effect of the concretes. n this study, Ecostone retaining wall method, which is a kind of environmentally friendly block, are used for verifying the application to the slope stability and protection of rural hosing. In case of rural hosing and structure, the height of the slope is not high and additional loading doesn't act on the slope except the gravity loading of housing and structure. From the result of the stability analysis of Ecostone, 3m to 7m Ecostone retaining wall can have an equivalence capacity comparing with the concrete retaining wall. Therefore, Ecostone method can apply to retaining wall with the structural safety and environmentally friendly aspect using the plants and vegetation.

  • PDF

고온 시편의 급랭 시 산화철 나노유체가 최소막비등점에 미치는 영향에 대한 실험적 연구 (Experimental Study on Effect of Water-based Iron(III) Oxide Nanofluid on Minimum Film Boiling Point During Quenching of Highly Heated Test Specimen)

  • 정찬석;황경섭;이치영
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.128-136
    • /
    • 2020
  • In the present experimental study, the effect of water-based iron(III) oxide nanofluid on the MFB(Minimum Film Boiling) point during quenching was investigated. As the highly heated test specimen, the cylindrical stainless steel rod was used, and as the test fluids, the water-based iron(III) oxide nanofluids of 0.001 and 0.01 vol% concentrations were prepared with the pure water. To examine the effect of location in the test specimen, the thermocouples were installed at the bottom and middle of wall, and center in the test specimen. Through a series of experiments, the experimental data about the influences of nanofluid concentrations, the number of repeated experiments, and locations in the test specimen on the reaching time to MFB point, MFBT(Minimum Film Boiling Temperature), and MHF(Minimum Heat Flux) were obtained. As a result, with increasing the concentration of nanofluid and the number of repeated experiments, the reaching time to MFB point was reduced, but the MFBT and MHF were increased. In addition, it was found that the effect of water-based iron(III) oxide nanofluid on the MFB point at the bottom of wall in the test specimen was observed to be greater than that at the middle of wall and center. In the present experimental ranges, as compared with the pure water, the water-based iron(III) oxide nanofluid showed that the maximum reduction of reaching time to MFB point was about 53.6%, and the maximum enhancements of MFBT and MHF were about 31.1% and 73.4%, respectively.

중국 성곽유적의 보존 및 관리 (A Study on the City Wall Ruins Preservation and Management of China)

  • 강태호;리아오페이
    • 건축역사연구
    • /
    • 제26권5호
    • /
    • pp.27-38
    • /
    • 2017
  • The main objective of this study is to analyze the preservation and management for the city wall ruins of China, and to find out the implications. Firstly, Chinese walls have experienced a process from demolition to protection. The walls of the historical value of the site are gradually being certified, and many walls ruins were designated as a conservation unit. Secondly, China's institutional system is based on the central government issued Cultural Relics P rotection Law and combined with the actual situation of local governments to establish a special law. Management System is Cultural Relics Bureau, the planning department, the garden department and the tourism sector joint implementation. Thirdly, through the study of Nanjing, Xian, Pingyao, Suzhou city wall ruins finding that perfect legislation and unified management system to help protect city wall ruins.

축소시편을 이용한 Bottom ash 경량콘크리트패널의 차음성능평가 (An acoustic evaluation of bottom-ash light-weigh concrete panel using small-scale Panel)

  • 정진연;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.951-955
    • /
    • 2007
  • Recently, drywall's demand is increasing by interest about spread of remodeling house and separated wall structure. This research evaluated panel's SRI and found out panel properties using material of small size. Conclusion of this research is as following. First, we confirmed the effectiveness of small-scale material. Measuring results appeared equally about 400 ${\sim}$ 500 Hz that is fc frequency. Second,, it is no big difference in SRI that use CRC or magnesium board that is used for protection of panel surface. Third, it is compared SRI by used junction to make wall that become disjointing assembly. By the result, sealed wall secures resemblant SRI performance almost with normal wall. Therefore, using joint materials and sealing junction became wall that is detached with high SRI.

  • PDF

고폭탄 탄약시험 간 이동형 강재 방호벽의 안전성능 판단 및 유효 방호력 평가 방법 (Method for evaluating the safety performance and protection ability of the mobile steel protective wall during the high-explosive ammunition test)

  • 전인범
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.573-582
    • /
    • 2021
  • 본 연구에서는 고폭탄과 같은 고위험 탄약에 대한 신뢰성 시험을 수행하는 기관에서 갖추어야 할 방호벽에 대해 유효 방호력을 평가하였다. 고폭탄이 인원에게 줄 수 있는 영향은 폭발압력에 의한 고막, 폐의 손상 등과 폭발과 동시에 발생한 파편에 의해 받을 수 있는 관통상이 있다. 따라서 COMP B가 충전되어있는 고폭탄을 기준으로, 피해 정도를 산정하기 위한 폭발방호 이론과 수치적 계산과 시뮬레이션을 통한 방호력 검증을 수행하였다. 수치적 계산 결과 시나리오로 설정된 방호벽과 폭발원점의 거리(7 m)에서 고폭탄 폭발 시 방호벽에 미치는 최대 폭발압력은 77.74 kPa이었으며, 50 mm 두께의 방호벽에 대한 파편의 관통력은 41.34 mm로 계산되었다. AUTODYN을 활용한 시뮬레이션 검증에서는 방호벽과 인원에게 영향을 주는 최대 폭발압력은 각각 58.68 kPa과 18.175 kPa이었으며, 파편의 관통력은 35.56 mm였다. 이 수치는 인간의 피해 한계보다 낮은 수치로 방호벽의 방호력은 유효할 것으로 판단되었다.

Impact of the Thruster Jet Flow of Ultra-large Container Ships on the Stability of Quay Walls

  • Hwang, Taegeon;Yeom, Gyeong-Seon;Seo, Minjang;Lee, Changmin;Lee, Woo-Dong
    • 한국해양공학회지
    • /
    • 제35권6호
    • /
    • pp.403-413
    • /
    • 2021
  • As the size of ships increases, the size and output power of their thrusters also increase. When a large ship berths or unberths, the jet flow produced from its thruster has an adverse effect on the stability of quay walls. In this study, we conducted a numerical analysis to examine the impact of the thruster jet flow of a 30,000 TEU container ship, which is expected to be built in the near future, on the stability of a quay wall. In the numerical simulation, we used the fluid-structure interaction analysis technique of LS-DYNA, which is calculated by the overlapping capability using an arbitrary Lagrangian Eulerian formulation and Euler-Lagrange coupling algorithm with an explicit finite element method. As the ship approached the quay wall and the vertical position of the thruster approached the mound of the quay wall, the jet flow directly affected the foot-protection blocks and armor stones. The movement and separation of the foot-protection blocks and armor stones were confirmed in the area affected directly by the thruster jet flow of the container ship. Therefore, the thruster jet flows of ultra-large ships must be considered when planning and designing ports. In addition, the stability of existing port structures must be evaluated.