• 제목/요약/키워드: Wall Pressure

검색결과 2,444건 처리시간 0.03초

파사드 일체형 자연순환 태양열온수기 유동해석 (Flow Analysis of Facade Integrated Solar Water Heater with Natural Circulation)

  • 백남춘;이왕제;임희원;신우철
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.167-172
    • /
    • 2016
  • Purpose: The solar water heater with natural circulation has been used for several decades in the world as it is automatically operated without a pump and controller and is easy to maintain and repair. After the subsidy was offered from 2012, the solar water heater with natural circulation is becoming increasingly popular in Korea. Recently, the development of a wall-integrated solar water heater, which improves the applicability of buildings and prevents the overheating in the summer, is being developed. On the other hand, the design and performance evaluation data of solar water heaters are very inadequate, and analysis of heat and flow is required to develop a new type of solar water heater. Method: Therefore, in this study, we proposed a new simplified system analysis model that reflects heat and pressure loss from the test results of KS B ISO 9806-1 (Solar collector test method), assuming that the collector is a simple pipe system, the validity of which was verified through experiments. Result: As a result, first, the RMSE of the system circulation flow rate and the average temperature of the inlet and outlet of the collector according to the experimental results and the simulation are 0.05563 and 0.88530, respectively, which are very consistent. Secondly, the mass flow rate is increased linearly with the increase of the solar radiation, and the mass flow rate is 0.0104 ~ 0.0180kg/s in the range of $200{\sim}380W/m^2$ of solar irradiance. Compared with the test flow rate 0.0764kg / s of the test collector, it showed a level of less than 20%.

회전하는 덕트내 설치된 $70^{\circ}$ 경사요철의 열전달 특성 (Heat Transfer in Rotating Duct with $70^{\circ}$ Angled Ribs)

  • 최청;이세영;원정호;조형희;박병규
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.7-13
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside a cooling passage of rotating gas-turbine blades. The rotating duct has staggered ribs with $70^{\circ}$ attack angle, which are attached on leading and trailing surfaces. Naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. Additional numerical calculations are conducted to analyze the flow patterns in the cooling passage. The present experiments employ two-surface heating conditions in the rotating duct because the exposed surfaces to hot gas stream are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. Secondary flows are generated by Coriolis and centrifugal forces in the spanwise and streamwise directions. The ribs attached on the walls disturb the mainflow resulting in recirculation and secondary flows near the ribbed wall. The local heat transfer and flow patterns in the passage are changed significantly according to rib configurations and duct rotation speeds. Therefore, the geometry and arrangement of the ribs are important for the advantageous cooling performance. The experimental results show that the ribs enhance the heat transfer more than $70\%$ from that of the smooth duct. The duct rotation generates the heat transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The overal heat transfer pattern on the leading and trailing walls for the first and second passes are depended on the rotating speed, but the local heat transfer trend is affected mainly by the rib arrangements.

  • PDF

스트레인 게이지를 이용한 부직포의 변형거동 계측 (Measurement of Nonwoven Geotextile Deformation with Strain Gauges)

  • 원명수;이용안;고형우;김유성;박병수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.96-102
    • /
    • 2006
  • Because of the increasing need to use clayey soil as the backfill in reinforced soil structures and embankment material, nonwoven geotextiles with the drain capability have been receiving much attention. However, there are few studies of the deformation behavior of nonwoven geotextiles at geosynthetics reinforced soil structures in the field because the nonwoven geotextile, which has low tensile stiffness and higher deformability than geogrids and woven geotextiles, is difficult to measure its deformation by strain gauges and to prevent the water from infiltrating. This study proposes a new, more convenient method to measure the deformation behaviour of nonwoven geotextile by using a strain gauge; and examines the availability of the method by conducting laboratory tests and by applying it on two geosynthetics reinforced soil (GRS) walls in the field. A wide-width tensile test conducted under confining pressure of 7kPa showed that the local deformation of nonwoven geotextile measured with strain gauges has a similar pattern to the total deformation measured with LVDT. In the field GRS walls, nonwoven geotextile showed a larger deformation range than the woven geotextile and geogrid; however, the deformation patterns of these three reinforcement materials were similar. The function of strain gauges attached to nonwoven geotextile in the walls works normally for 16 months. Therefore, the method proposed in this study for measuring nonwoven geotextile deformation by using a strain gauge proved useful.

  • PDF

자유류 난류와 표면 트립 와이어가 구 주위 유동에 미치는 영향 (Effects of the Free-Stream Turbulence and Surface Trip Wire on the Flow past a Sphere)

  • 손광민;최진;전우평;최해천
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.187-190
    • /
    • 2006
  • In the present study, effects of tree-stream turbulence and surface trip wire on the flow past a sphere at $Re\;=\;0.4\;{\times}\;10^5\;{\sim}\;2.8\;{\times}\;10^5$ are investigated through wind tunnel experiments. Various types of grids are installed upstream of the sphere in order to change the tree-stream turbulence intensity. In the case of surface trip wire, 0.5mm and 2mm trip wires are attached from $20^{\circ}\;{\sim}\;90^{\circ}$ at $10^{\circ}$ interval along the streamwise direction. To investigate the flow around a sphere, drag measurement using a load cell, surface-pressure measurement, surface visualization using oil-flow pattern and near-wall velocity measurement using an I-type hot-wire probe are conducted. In the variation of free-stream turbulence, the critical Reynolds number decreases and drag crisis occurs earlier with increasing turbulence intensity. With increasing Reynolds number, the laminar separation point moves downstream, but the reattachment point after laminar separation and the main separation point are fixed, resulting in constant drag coefficient at each free-stream turbulence intensity. At the supercritical regime, as Reynolds number is further increased, the separation bubble is regressed but the reattachment and the main separation points are fixed. In the case of surface trip wire directly disturbing the boundary layer flow, the critical Reynolds number decreases further with trip wire located more downstream. However, the drag coefficient after drag crisis remains constant irrespective of the trip location.

  • PDF

The effect of sildenafil on right ventricular remodeling in a rat model of monocrotaline-induced right ventricular failure

  • Bae, Hyun Kyung;Lee, Hyeryon;Kim, Kwan Chang;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • 제59권6호
    • /
    • pp.262-270
    • /
    • 2016
  • Purpose: Pulmonary arterial hypertension (PAH) leads to right ventricular failure (RVF) as well as an increase in pulmonary vascular resistance. Our purpose was to study the effect of sildenafil on right ventricular remodeling in a rat model of monocrotaline (MCT)-induced RVF. Methods: The rats were distributed randomly into 3 groups. The control (C) group, the monocrotaline (M) group (MCT 60 mg/kg) and the sildenafil (S) group (MCT 60 mg/kg+ sildenafil 30 mg/kg/day for 28 days). Masson Trichrome staining was used for heart tissues. Western blot analysis and immunohistochemical staining were performed. Results: The mean right ventricular pressure (RVP) was significantly lower in the S group at weeks 1, 2, and 4. The number of intra-acinar arteries and the medial wall thickness of the pulmonary arterioles significantly lessened in the S group at week 4. The collagen content also decreased in heart tissues in the S group at week 4. Protein expression levels of B-cell lymphoma-2 (Bcl-2)-associated X, caspase-3, Bcl-2, interleukin (IL)-6, matrix metalloproteinase (MMP)-2, endothelial nitric oxide synthase (eNOS), endothelin (ET)-1 and ET receptor A (ERA) in lung tissues greatly decreased in the S group at week 4 according to immunohistochemical staining. According to Western blotting, protein expression levels of troponin I, brain natriuretic peptide, caspase-3, Bcl-2, tumor necrosis factor-${\alpha}$, IL-6, MMP-2, eNOS, ET-1, and ERA in heart tissues greatly diminished in the S group at week 4. Conclusion: Sildenafil alleviated right ventricular hypertrophy and mean RVP. These data suggest that sildenafil improves right ventricular function.

큰 박리유동을 동반한 초음속 관통형 핀틀노즐 유동에 적합한 2-방정식 난류모델의 압축성계수 보정 영향 (Compressibility Correction Effects of Two-equation Turbulence Models for a Supersonic Through-type Pintle Nozzle with Large Scale Separation Flow)

  • 허준영;정준영;성홍계;양준서;이지형
    • 한국추진공학회지
    • /
    • 제17권1호
    • /
    • pp.61-69
    • /
    • 2013
  • 핀틀 움직임에 의해 발생되는 큰 유동박리에 대해 적합한 2-방정식 난류모델의 압축성계수 보정모델을 판단하기 위하여 수치적 연구를 수행하였다. 난류모델은 저 레이놀즈수 k-${\varepsilon}$ 모델과 k-${\omega}$ SST 모델에 압축성 보정 모델(Wilcox와 Sarkar 모델)을 적용하여, 핀틀 노즐의 세부유동장을 관찰하고 노즐 벽면에서의 압력을 실험데이터와 비교 분석하였다. 마하디스크(Mach disk)의 위치와 박리영역에서의 압력 회복 형태는 난류모델에 따라 다르게 나타났으며, 각 난류모델에 압축성 보정을 적용하여 유동 박리 포획의 정확도를 개선하였다. 압축성이 보정된 k-${\varepsilon}$ 모델이 실험결과와 매우 잘 일치하였다.

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

흑운모화강암 지역에 대한 수압암반절개기술의 현장 적용 (Field Application of Hydraulic Rock Splitting Technique to Biotite Granite)

  • 박종오;이달희;우익
    • 터널과지하공간
    • /
    • 제27권5호
    • /
    • pp.263-270
    • /
    • 2017
  • 수압암반절개기술은 천공된 시추공에 설치된 이중패커의 인터벌에 암반의 인장응력 이상의 수압을 가하여 균열을 발생시킴으로써 암반을 절개시키는 방법이다. 본 연구에서는 흑운모화강암 사면에 대하여 다양한 배열설계 및 주입설계에 따라 수압암반절개기술을 현장에 적용하였다. 실험 결과, 주입에 따라 새로운 균열이 발생되어 주변 공과 연결되거나 기존 균열이 연장되어 암반이 파괴되었다. 특히, 본 실험에서는 유도 슬롯과 평행한 방향을 지닌 균열이 발생되어 균열 생성방향을 제어할 수 있는 가능성을 제시하였다. 균열생성에 대한 제어 기술을 발전시키기 위해선, 균열생성에 영향을 미치는 여러 요소를 고려한 다양한 배열설계 및 주입설계를 암반 현장에 적용하여야 할 것이다.

도로성토하중경감재 EPS의 공학적 특성에 관한 연구 (A Study on Engineering Characteristics of Load Reducing Material EPS)

  • 장명순;천병식;임해식
    • 한국지반공학회지:지반
    • /
    • 제12권2호
    • /
    • pp.59-70
    • /
    • 1996
  • 도로성토 하중저감공법중의 하나인 EPS공법은 초 경량재(20~30kg/m3)로서 연약지반상에 성토재로 사용하여 지반의 유효응력 증가분을 최소화함으로써 지지력과 침하에 대한 안정성을 쉽게 확보할 수 있고, 옹벽.교대등의 구조물 뒤채움재나 응급 복구용 채움재로 활용할 경우 토압 경감효과를 기대할 수 있다. 그러나 아직까지 국내에서는 공학적 성토 재료로서 활용하기 위한 물성 시험 방법이 정확히 확립되어 있지 않고 보온 재료로서의 시험 방법 및 품질 규정만이 KS에 규정되어 있다. 그로 인해 생산되는 EPS의 체계적인 토질공학적 시험 데이터 없이 성토 재료로 사용하고 있는 실정이다.따라서 본 연구에서는 공학적 재료로 활용하기 위해 필요한 강도특성, 변형특성, 흡수특성, 크리프특성 등에 대해 시험을 통하여 공학적 특성을 규명하였고, 보다 적합한 품질 규정의 제정 필요성과 일축압축강도에 의한 설계기준강도를 제안하였다.

  • PDF

아크튜브내의 구성물 손실이 세라믹 메탈 핼라이드 램프의 특성에 미치는 영향분석 (Analysis of the Effect on the Performance of Ceramic Metal Halide Lamp by the Loss of Elements that have been Filled in Arc Tube)

  • 장혁진;양종경;박대희
    • 전기학회논문지
    • /
    • 제58권12호
    • /
    • pp.2446-2452
    • /
    • 2009
  • A Ceramic Metal-halide lamp is achieved by adding multiple metals to a basic mercury discharge. Because the vapor pressure of most metals is very much lower than mercury itself, metal-halide salts of the desired metals, having higher vapor pressures, are used to introduce the material into the basic discharge. The metal compounds are usually polyatomic iodides, which vaporize and subsequently dissociate as they diffuse into the bulk plasma. Metals with multiple visible transitions are necessary to achieve high photometric efficiency and good color. Compounds of Sc, Dy, Ho, Tm, Ce, Pr, Yb and Nd are commonly used. The maximum visible efficacy of a Ceramic Metal Halide lamp, under the constant of a white light source, is predicted to be about 450lm/W. This is controlled principally by the chemical fill chosen for a particular lamp. Current these lamps achieve 130lm/W and these life time are the maximum 16,000[hr]. So factors of performance lower are necessary to improve lamp performance. In this paper, we analyzed factors of performance lower by accelerated deterioration test. The lamp was operated with short duration turn-on/turn-off procedure to enhance the effect due to electrode sputtering during lamp ignition. The tested lamp that was operated with a longer turn-on/off(20/20 minutes) showed blackening, changed distance between electrodes and lowered color rendering & color temperature by losses of Dy at 421.18nm, I at 511nm, T1 at 535nm and Na at 588nm compared with the new lamp.