• Title/Summary/Keyword: Wall Loss

Search Result 785, Processing Time 0.029 seconds

Simulation of the Thermal Performance on an Ondol House with Hot Water Heating in Consideration of Radiation Heat Transfer (복사열전달을 고려한 모형 온수온돌 주택 열성능 시뮬레이션)

  • Choi, Y.D.;Yoon, J.H.;Hong, J.K.;Lee, N.H.;Kang, D.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.295-305
    • /
    • 1993
  • Thermal performance of test cell of model hot water Ondol house was simulated by equivalence heat resistence and heat capacity method. In this method wall was replaced by two equivalence and one heat capacity. This method enables to simulate the variation of temperature of each element of model house. The effect of pipe diameter, pitch of pipe and with or without consideration of inter-radiation between wall surfaces on the energy consumption rate were investgated. Results show that radiations between the ground surface of room and wall surfaces contribute to the heating of room air by reducing the convection heat loss through the wall surfaces.

  • PDF

Thermal Performance of TI-wall System (투과형단열재 부착 건물외피구조체의 열성능)

  • Yoon, Yong-Jin;Kim, Hea-Jeong;Kim, Byoung-Soo
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.121-128
    • /
    • 2004
  • One of the most weak parts for energy loss through the whole building components are building envelopes. Lots of technbologies to increase the thermal performance of building envelopes have been introduced in recent years. Transparent insulation is a new technology for building insulation and has function both solar transmittance and thermal insulation. This study has been carried out to develope the transparent insulation panels and TI-wall system and to analyze the thermal performance of TI-wall system by experiments using test-cell and dynamic energy simulation program ESP-r 9.0. This system is regarded as a efficient building envelope system suitable for to reduce the heating and cooling load of the buildings in our country.

Effect of Wall Thinning on the Failure of Pipes Subjected to Bending Load (굽힘하중을 받는 배관의 파손에 미치는 감육의 영향)

  • Ahn Seok-Hwan;Nam Ki-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.606-613
    • /
    • 2005
  • Effects of circumferentially local wall thinning on the fracture behavior of pipes were investigated by monotonic four-point bending. Local wall thinning was machined on the pipes in order to simulate erosion/corrosion metal loss. The configurations of the eroded area included an eroded ratio of d/t= 0.2, 0.5, 0.6, and 0.8, and an eroded length of ${\ell}\;=10mm,$ 25mm, and 120mm. Fracture type could be classified into ovalization, local buckling, and crack initiation depending on the eroded length and eroded ratio. Three-dimensional elasto-plastic analyses were also carried out using the finite element method, which is able to accurately simulate fracture behaviors excepting failure due to cracking. It was possible to predict the crack initiation point by estimating true fracture ductility under multi-axial stress conditions at the center of the thinned area.

Failure Criterion of Straight Pipe with Outer Local Wall Thinning under Internal Pressure (내압을 받는 외부 국부 감육 직관의 파손 기준)

  • Kim, Soo-Young;Nam, Ki-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.76-83
    • /
    • 2014
  • This study was carried out an experimental and finite element analysis on the fracture behavior of straight pipes with local wall thinning under internal pressure. Local wall thinning was machined on the pipes in order to simulate erosion/corrosion metal loss. The configurations of the eroded area has an eroded ratio of d/t=0.80~0.92 and an eroded length of l=25, 50 and 102 mm. Three-dimensional elastic-plastic analyses were also carried out using the finite element method, which is able to accurately simulate failure behaviors. In regards to the relation ship between pressure and eroded ratio, the criterion that can be used safely under operating pressure and design pressure were obtained from this calculation. The results of this calculation were in relatively good agreement with that of the experiment.

Analytical study on the Subchannel Pressure Loss for Turbulent Flow in Bare Rod Bundles (핵연료봉 주위에 형성되는 난류유동장에서 부수로 압력손실에 대한 해석적 연구)

  • ;Lee, Kye Bock
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2630-2636
    • /
    • 1995
  • A theoretically based prediction for the determination of the subchannel friction factor at low pitch to the rod diameter ratio (P/D < 1.2) in the bare rod bundle flow has been developed. The present model assumes the validity of the Law of Wall over the entire flow area. The algebraic form of the Law of the Wall is integrated over the entire flow area and the local friction velocity variation along the rod periphery is considered in this study. The present method is applied to the rod bundles with P/D < 1.2, and the prediction results show good agreement with the available experimental data.

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.

Estimation of Damage Degree for Mural Paintings in Maitreya Hall of Geumsan-sa Buddhist Temple, Korea (금산사 미륵전벽화의 손상도 평가 연구)

  • Han, Kyeong-Soon
    • Journal of Conservation Science
    • /
    • v.26 no.3
    • /
    • pp.295-310
    • /
    • 2010
  • Since wall paintings in Maitreya Hall of Geumsan-sa temple had displayed a serious state of damage and deterioration, a detailed examination such as structural analysis of the wall, cause of damage, and the state of deterioration have been thoroughly conducted before the conservation treatment has commenced. The most seriously deteriorated part of the wall paintings was the south wall of the building in particular in its painted and surface layer. The painted layer had formed its own layer of thick, which has been separation from the surface layer. As such problem developed the whole surface layer has been separated from the wall. The problem has been caused by two reasons: 1. the heavy weight of the roof section and it caused cracks and damage on the wall; 2. the loss of function of consolidating material and it caused discolouring and the separation of surface layer from the wall. The cause of damage on the painted and surface layers can be assumed in two ways: 1. its surrounding environment such as the change of temperature and humidity level and ultraviolet rays ; 2. the loss of mechanical function of consolidating material, synthetic resin which had been applied in the past conservation treatment. The separation of layers from the wall and cracks was caused by the mistake in choosing an applicable consolidating material and dismantling technique which had ignored a different characteristic of the wall painting of Korean buddhist temples.

The Fluid Loss and Sealing Mechanisms in Slurry Trench Condition (I) : A Large Scale Test and Design Procedure (Slurry wall 공법에서 안정액의 역할 (I) : 대형모형실험과 설계절차)

  • Kim, Hak-Moon
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.239-248
    • /
    • 2002
  • Bentonite slurries in a slurry wall construction must fulfill a stabilizing function by forming impermeable membrane (surface cake and penetrated cake) on the excavated soil faces. Thus problems are occurring in practice for the construction of diaphram walls and cut-off walls with a low permeability for wastes disposal areas in some deep excavations or different grounds. In this paper, the fundamental mechanics of fluid loss and filter cake formation in various soil beds are investigated using large scale laboratory apparatus. The sealing efficiency of filter cake from the large scale tests and the significance of fluid loss in a slurry trench are utilized for practical situation as a recommended design procedure.

A Computational Study of Flowfield for a Vent Mixer in Supersonic Flow (초음속 유동장 내 벤트 혼합기에 관한 수치해석 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.33-39
    • /
    • 2008
  • To improve the mixing efficiency and to reduce the pressure loss, it is needed to develope a new mixing device for supersonic combustion. The vent mixer is introduced as the new supersonic fuel-air mixer. Computational analyses, that include pressure profile, density contour, and streamline tracing, have been carried out. The expansion wave generates at the end of the extended upper wall of the mixer. And it reduces the shock wave from the hole. Incoming air flow through the hole makes several recirculation regions which increase the mixing efficiency, and the separation region at the downward wall expends the boundary layer which reduces the pressure loss.