• 제목/요약/키워드: Walking Shoe

검색결과 101건 처리시간 0.023초

하지 근육의 피로상태 동안 높은 굽 신발에 적용한 전면접촉인솔이 젊은 여성의 보행 특성에 미치는 영향 (The Effect of High-Heeled Shoes With Total Contact Inserts in the Gait Characteristics of Young Female Adults During Lower Extremity Muscle Fatigue)

  • 고은혜;최흥식;김택훈;신헌석;권오윤;최규환
    • 한국전문물리치료학회지
    • /
    • 제15권1호
    • /
    • pp.38-45
    • /
    • 2008
  • This study investigated gait characteristics, kinematics, and kinetics in the lower extremities between two different shoe conditions (high heeled shoes (7 cm), and high heeled shoes with a total contact insert (TCI)) after lower extremity muscle fatigue. Although TCI shave been applied in high heeled shoes to increase comfort and to decrease foot pressure, no study has attempted to identify the effects of TCI in fatigue conditions. The purpose of this study was to determine the effects of walking in high heeled shoes with TCI after lower extremity muscle fatigue was induced. This study was carried out in a motion analysis laboratory at Hanseo University. A volunteer sample of 14 healthy female subjects participated. All in fatigue conditions, the subjects were divided into two groups. The muscle fatigue was induced by 40 voluntary dorsi- and plantar-flexion exercises and 40 heel-rise exercises of the dominant foot. Surface electromyography was used to confirm the localized muscle fatigue using power spectral analysis of three muscles (tibialis anterior, gastrocnemius medialis and lateralis). The results were as follows: (1) In muscle fatigue conditions, the use of TCI decreased the peak flexion angle of the hip joint significantly in the early stance phase (p<.05) and increased the peak hip flexion moment in the terminal stance phase (p<.05). (2) In muscle fatigue conditions, the application of TCI also increased peak hip power generation in the early stance phase and peak hip power absorption in the terminal stance phase (p<.05). (3) In muscle fatigue conditions, the use of TCI reduced the impact force significantly and increased the secondary peak vertical GRF. These findings suggest that the TCI may provide beneficial effects when muscle fatigue occurs for a high heeled shoe gait. Future research employing the patient population and various types of TCI materials are required to clarify the effects of TCI.

  • PDF

보행 시 신발 굴 높이어 따른 발/발목 복합체의 Roll-Over특성 (Foot/Ankle Roll-Over Characteristics According to Different Heel Heights of Shoe during Walking)

  • 김영호;최희석
    • 비파괴검사학회지
    • /
    • 제25권4호
    • /
    • pp.247-253
    • /
    • 2005
  • 본 연구에서는 여러 굽 높이의 신발을 신고 보행하는 동안 발/발목 복합체의 roll-over 모양을 분석하였다. 본 연구를 위해서 근골격계 및 발 질환이 없는 15명의 건강한 성인 여성들을 대상으로 보행분석을 수행하였고, 실험에는 굽 높이가 다른 4종의 신발을 사용하였다. 보행분석 시 roll-over의 특성을 구하기 위해 초기접지기부터 반대발 초기접지기까지의 발목 및 무릎의 반사마커 궤적과 지면반발력의 압력중심 데이터를 이용하였다. 연구결과로 굽 높이가 증가할수록 roll-over의 모양은 원위방향으로 이동하고 그 특성은 굽 높이에 상관없이 일정한 형태로 관찰되었다. 또한, 6cm이하의 신발에서는 roll-over의 곡률중심이 수직방향으로 이동함으로써 일정한 roll-over 특성을 유지하도록 발/발목 복합체에서 자동으로 적응함을 알 수 있었다. 그러나 그 이상의 굽 높이의 신발에서는 발목관절만으로 충분한 균형을 보장할 수 없으므로 무릎 및 엉덩관절의 보상작용이 동시에 일어남을 알 수 있었다. Roll-over 특성에 대한 본 연구결과는 인간 보행의 보다 간단하고 넓은 이해를 제공할 것이고, 나아가 의지 또는 보조기와 같은 재활기기의 보다 넓은 이해를 제공할 수 있을 것으로 기대된다.

가속도계를 이용한 보행 시점 검출 알고리즘 개발 (Development of Gait Event Detection Algorithm using an Accelerometer)

  • 최진승;강동원;문경률;방윤환;탁계래
    • 한국운동역학회지
    • /
    • 제19권1호
    • /
    • pp.159-166
    • /
    • 2009
  • 본 연구의 목적은 실외 보행 실험 시 사용하기에 간편한 가속도계를 이용하여 보행 이벤트를 자동으로 검출하는 알고리즘을 개발하고 검증하는 것이다. 개발된 알고리즘은 신발의 발등에 부착된 3축 가속도계의 가속도의 총합과 보행 진행 방향(x축) 가속도를 이용하였다. 가속도 총합은 착지 시점의 검출에, x축 가속도는 이지 시점의 검출에 각각 사용되었다. 7명의 피험자가 느린 보행 속도 선호 보행 속도 빠른 보행 속도로 보행 실험을 수행하였고, 개발된 알고리즘의 검증을 위해 지면반력기를 포함한 3차원동작분석시스템과 동시에 실시되었다. 지면반력기를 이용한 보행 시점을 기준으로, 기존에 발표된 동작 자료만을 이용한 알고리즘을 통하여 얻어진 보행 시점도 함께 비교 하였다. 그 결과, 고안된 알고리즘의 정확도는 지면반력기를 이용한 값에 평균, 착지시점은 $22.33{\pm}17.45ms$, 이지시점은 $26.82{\pm}14.78ms$의 차이가 났고, 그 오차의 패턴이 일관적으로 20ms가량 먼저 검출되는 경향이 있었다. 일반적으로 트레드밀 실험에서 많이 사용되는 동작데이터를 통한 보행 시점의 비교에서도 크게 차이를 보이지 않았다. 그러므로 개발된 알고리즘은 실외 실험의 보행 시점 검출에 이용할 수 있을 것으로 판단된다. 추후 연구로는 현재의 가속도계만으로 보행 시점뿐 만아니라, 중력가속도 성분을 제거하여 보행 공간변인의 추출이 필요할 것이다.

보행시 지반조건에 따른 팽이기초를 접목시킨 신발 족저압 분포 비교분석 (Top shoes foot pressure basis of the comparison analysis combine conical top foundation walking upon ground conditions)

  • 김연덕;김석진;민병헌;김상환
    • 한국산학기술학회논문지
    • /
    • 제20권9호
    • /
    • pp.20-28
    • /
    • 2019
  • 본 논문은 지반 조건에 따라 현재 개발 중인 팽이기초를 접목한 신발과 일반적인 신발인 워킹화의 보행시 압력분포의 비교분석에 대한 연구이다. 일반적인 신발, 현재 개발 중인 팽이기초를 접목한 신발 두 가지 카테고리의 신발이 본 연구에 사용되었으며, 실험 대상은 260mm를 착용하는 정상발의 조건에 만족하는 15명의 20대 남성을 대상으로 단단한 지반, 모래 지반에서의 실험을 실시하였다. 보행 시 압력의 측정은 Techstorm사의 무선 Insole System 을 사용하여 측정하였으며 발의 7 Zone에서 족저압을 측정하였다. 연구 결과 신발과 지반 조건에 따라 다른 최대 힘, 평균 압력, 압력 분포도를 나타냈으며, 본 연구 결과 단단한 지반 및 모래 지반에서 발 부위에 따라 족저압 분산 효과가 일반적인 신발과 현재 개발 중인 팽이기초를 접목한 신발이 서로 상이한 것을 확인할 수 있었다. 향후 보다 지속적인 연구를 통해 다양한 고무 소재를 선택하여 추가적인 실험을 통해 단단한 지반 및 모래 지반에서 모두 착용 가능한 신발의 개발에 유용하게 사용될 것으로 기대된다.

편마비 환자의 대칭적 체중부하 유도를 위한 청각적 피드백 보행훈련 시스템 개발 및 평가 (Development and Evaluation of the Auditory Feedback Gait Training System Induced Symmetrical Weight-Bearing in Hemiplegic Patients)

  • 권용찬;이현주;태기식
    • 재활복지공학회논문지
    • /
    • 제6권2호
    • /
    • pp.23-30
    • /
    • 2012
  • 본 연구에서는 로드셀 센서를 활용하여 편바미 환자의 환측에 부하되는 체중부하에 따른 청각적 피드백을 적용한 대칭 보행유도와 보행패턴 분석이 가능한 무선 보행훈련 시스템을 개발하였다. 또한 개발된 시스템의 유효성을 검증하기 위해 정상인군 및 편마비군 대상자에게 수행한 임상실험을 진행하였으며, 각 대상군마다 피드백 적용 후 보행 속도와 체중 부하량, 그리고 보행 시 입각기비율과 분속수가 증가하였음을 확인하였다. 연구 결과를 토대로 편마비 환자 뿐만 아니라 대칭적 체중부하가 요구되는 다양한 하지 질환자들에 대한 임상실험을 확대하고 장기간 훈련의 효과를 관찰한다면, 본 연구에서 개발된 청각적 대칭 체중부하 피드백 보행 시스템은 다양한 패턴 분석과 함께 보행 향상을 위한 기기 적용이 가능할 것으로 기대된다.

  • PDF

12주간의 불안정성 신발 착용이 직립 자세 및 보행역학에 미치는 영향 (Effects of 12-week Wearing of the Unstable Shoes on the Standing Posture and Gait Mechanics)

  • 박기란;안송이;이기광
    • 한국운동역학회지
    • /
    • 제16권3호
    • /
    • pp.165-172
    • /
    • 2006
  • The purpose of this study was to determine effects of 12-week wearing of unstable shoe on the standing posture and gait mechanics. Nine healthy men were asked to wear the unstable shoes for 12-week and walk for 30 minute everyday. Their standing posture and gait mechanics were measured before and after treatment. Standing posture was measured for each side(anterior, posterior, lateral) for standing position. And gait analysis was measured joint angle of a right lower limb between first right heel contact and second right heel contact. Kinematic data were collected using video camera at 30 frame per seconds. Statistical analysis was paired t-test(p<.05) to compare before training with after that. A head tilt angle was significantly decreased for posterior side(p<.05). The angle of between center of line and surface was significantly decreased at midstance and take off during walking(p<.05). Ankle dorsiflexion significantly increased at heel contact2(p<.05) and ankle plantarflexion significantly increased at midstance and midswing(p<.05). The increase of ankle dorsiflexion showed that our results consisted with previous study. In conclusion, there was not large significant difference in static standing posture but joint angle of lower limb represented many changes with increasing of ankle motion during walking. These were of benefit to body by increasing leg muscle activity but it was necessary for man having a ankle problem to consider. Further studies concerning optimum outsole angle of unstable shoes are necessary.

스마트 신발을 활용한 보행분석 시스템 활용 가치에 대한 논의 (Discussion on the Value of Using Gait Analysis System Using Smart Shoes)

  • 박태성;신명준;이은이
    • 융합정보논문지
    • /
    • 제9권3호
    • /
    • pp.128-133
    • /
    • 2019
  • 본 연구는 정상인에게 스마트 신발을 착용 시킨 후, 6분 보행검사와 일어나 걸어가기 검사를 실시하여 연구자가 측정한 데이터와 스마트 신발 센서 데이터가 동일 및 유사한지 확인 하고자 하였다. 정상 성인 남성 10명으로 진행을 하였으며 스마트 신발을 착용 한 후 6분 보행검사와 일어나 걸어가기 검사를 실시하여 데이터를 분석 하였다. 본 실험의 결과를 보았을 때 현재 센서의 정확도는 높은 편으로 보여 진다. 6분 보행검사의 거리에 차이가 나타난 것은 실제 30m 트랙에서 계산하지 않는 반환점도 거리를 측정하기 때문에 차이가 나타난 것으로 보인다. 이러한 관점에서 보았을 때 스마트 신발이 좀 더 정확한 거리를 측정 하였다고 볼 수가 있으며 추후 스마트 센서를 통한 다양한 검사가 가능 할 것으로 보여 진다.

요측 전완부 피판을 이용한 족부 재건 - 21례에 대한 임상적 고찰 - (Foot Reconstruction using Radial Forearm Free Flap - Review of 21 Cases -)

  • 이광석;이승준;송형석;김상범
    • Archives of Reconstructive Microsurgery
    • /
    • 제12권2호
    • /
    • pp.119-124
    • /
    • 2003
  • Introduction : The purpose is a retrospective evaluation of the clinical results of the radial forearm flap transfer for foot reconstruction. Materials and methods : We evaluated 21 cases with medical records including etiology, wound dimension, presence of infection, associated fracture, ischemic time of free flap, complication of donor and recipient site. The final results were evaluated with our clinical score (walking, shoe-in, cosmetic). Results : Defects were located on the heel (12 cases), dorsum of foot (4 cases) and sole (5 cases). Mean wound dimension was $7.56{\times}6.0cm$, and mean ischemic time of free flap was 94.5minute. There were superficial skin necrosis (1 case), recurrent ulceration (2 cases) in recipient site, and no complication in donor site but complaint about cosmetic problem (3 cases). The clinical score showed excellent in 14 cases, good in 4 cases, fair in 1 case and poor in 2 cases. Conclusion : We consider the radial forearm flap could provid the stable and durable restoration of normal foot contour without debulking in the foot reconstruction and achieved normal ambulation and cosmetic satisfaction.

  • PDF

정상인 대상으로 기능성 인솔과 결합한 보호형 양말이 발바닥 압력에 미치는 영향: 예비 실험 연구 (The Effect of Protective Socks Combined with Functional Insole on Plantar Foot Pressure in Healthy Adults: A Pilot Study)

  • 정도영
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.147-154
    • /
    • 2018
  • PURPOSE: This study examined the ability of experimental socks combined with a functional insole to reduce plantar foot pressure in healthy subjects. METHODS: The study enrolled 15 subjects. An in-shoe measurement device was used to measure the peak plantar pressure while walking. The peak forefoot, midfoot, and hindfoot plantar pressure data were collected under two conditions: the subjects were wearing their own socks and while they were wearing the experimental socks. The paired t-test was used to determine the differences in peak plantar pressure between the two conditions at all three positions. RESULTS: Wearing the experimental socks resulted in a significantly higher peak plantar pressure in the medial forefoot and midfoot areas than wearing one's own socks (p<.05), and also in significantly lower peak plantar pressure in the medial and lateral hindfoot (p<.05). However, there were no significant differences of peak plantar pressure between experimental and own socks in middle and lateral forefoot (p>.05). CONCLUSION: The experimental socks combined with a functional insole decreased plantar pressure in the hindfoot and supported the medial longitudinal arch. However, it is necessary to change the design and material of the forefoot area in the functional insole to prevent foot ulcer at that location in people with diabetes mellitus.

다기능성 인솔 착용 시 하지의 근활성도 분석 (The Analysis of Muscle Activities on the Lower Limb during Wearing Functional Insole)

  • 박재영
    • 한국운동역학회지
    • /
    • 제20권3호
    • /
    • pp.327-336
    • /
    • 2010
  • The purpose of this study was to analyze muscle activities on functional insole with diet effect. Originally, ten healthy female subjects with an average age of 23.2 year(S.D=1.1), weight of 49.7 kg(S.D=4.9), height of 163.2 cm(S.D=3.5) and a shoe size of 237.5 cm(S.D=4.9) were participated in this experiment. Ten healthy females walked on a treadmill(speed=about 4.2 km/h) wearing two different insole types. Muscle activities data was collected using the EMG operating system. The surface EMG signal for tibialis anterior(TA), gastrocnemius(GA), vatus lateralis(VL) and biceps femoris(BF) were acquired at the RMS(10 Hz, 350 Hz) using Noraxon Telemyo DTS system(Noraxon inc, USA). This study processed the data using the Windows SPSS ver.17.0 to get an independent t-test, with the setting, p<.05. Analysis of muscle activity were measured and calculated during walking. The results are as follow: Functional insole wearing were increased muscle activities significantly from Tibialis anterior(TA) during total gait cycle. Normal distribution was demonstrated in total step of stances period. One foot standing position showed decreased muscle activity. Two foot standing position was demonstrated with gastrocnemius and biceps femoris. As a result of the analysis, Functional insole will inerease the diet effect in the use of four muscle groups.